AxiEM 9733367Recalls & reported problems
Medtronic Navigation, Inc. · POINTER 9733367 TRACER AxiEM · Class 2
All models of AxiEM (12)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00613994333780), received between Oct 31, 2018 and Oct 31, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Human-Device Interface Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Human-Device Interface Problem1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 31, 2018Human-Device Interface Problem; Human-Device Interface Problem
MEDTRONIC RECEIVED INFORMATION REGARDING A NAVIGATION DEVICE BEING USED FOR A CATHETER PLACEMENT PROCEDURE. IT WAS REPORTED THE TRACER PROBE STOPPED TRACKING INTRAOPERATIVELY. THE TRACER PROBE WAS REPORTEDLY DAMAGED. THE SITE HAD SUCCESSFULLY REGISTERED THE PATIENT, THEN BEGAN MOVING THE PATIENT¿S HEAD TO BEGIN SURGERY. THE MEDTRONIC REPRESENTATIVE (REP) ON SITE NOTICED MOVEMENT IN THE PATIENT REFERENCE FRAME WHILE THE SITE WAS MOVING THE PATIENT¿S HEAD. THE REP HAD THE SITE CHECK ACCURACY, AND THEY WERE NO LONGER ACCURATE. THE SITE SWITCHED PATIENT TRACKERS AND BEGAN DOING ANOTHER REGISTRATION. WHILE REGISTERING THE SECOND TIME, THE TRACER PROBE WAS NOT TRACKING. THE PORT ON THE AXIEM BOX WAS GREEN; THE REP MOVED THE EMITTER AND COULD NOT GET THE PROBE TO TRACK. THE TRACER PROBE WAS REPLACED, AND THE NEW PROBE SUCCESSFULLY TRACKED. THE SITE WAS ABLE TO REGISTER AND CONTINUE THE CASE. THERE WAS A SURGICAL DELAY OF LESS THAN 1 HOUR DUE TO THIS ISSUE, AND THERE WAS NO IMPACT ON PATIENT OUTCOME.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8026583 ↗
Other Neurological stereotaxic Instrument devices
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument4 deaths4,668 reports
- Stealthstation® S7™ 9733856Medtronic Navigation, Inc. · Neurological stereotaxic Instrument6 deaths3,908 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death1,896 reports
- StealthStation S8 9735669Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1,831 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument2 deaths1,542 reports
- Fusion™ ENT Image Guidance System 9733560XOMMedtronic Navigation, Inc. · Neurological stereotaxic Instrument1,316 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument8 deaths984 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death695 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page