Clydesdale™ Spinal System 2968040Recalls & reported problems
Medtronic Sofamor Danek, Inc. · CAGE 2968040 CLYDESDALE PEEK IB 6 10X40 · Class 2 · Implant
All models of Clydesdale Spinal System (25)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00613994485878), received between Feb 10, 2017 and Feb 22, 2023 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
8 other recalls cover devices cleared under the same FDA submission (K100175, P000058); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break2
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 22, 2023Break; Break
INFORMATION WAS RECEIVED FROM A HEALTHCARE FACILITY (HCP) VIA MANUFACTURER REPRESENTATIVE REGARDING SPINAL PRODUCT WHICH IS USED IN OBLIQUE LATERAL INTERBODY FUSION (OLIF) SPINAL THERAPY. IT WAS REPORTED THAT WHILE INSERTING THE CAGE THE SURGEON IMPACTED ON CAGE INSERTER WITH MALLET, THEN HE TRIED TO TURN THE DIRECTION INTO ORTHOGONALLY. THE CAGE HOLDER WAS DISENGAGED FROM THE CAGE AS THE THREAD PORTION OF THE CAGE WAS BROKEN. THERE WERE NO BROKEN FRAGMENTS LEFT INSIDE THE PATIENT AND NO FURTHER COMPLICATIONS OR SYMPTOMS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16415743 ↗MalfunctionFeb 10, 2017Break; Break
IT WAS REPORTED THAT PATIENT WITH LUMBAR KYPHOSIS UNDERWENT OBLIQUE LUMBAR INTERBODY FUSION AT L4/5. INTRA-OP, CAGE BROKE. THE CAGE WAS INSERTED HALFWAY, THEN IT WAS REMOVED BECAUSE ITS POSITION WAS NOT PROPER. WHEN THE SURGEON CHECKED THE CAGE, IT WAS FOUND THAT ITS CONNECTING PART WITH THE INSERTER WAS DAMAGED. NO FRAGMENTS OF THE PRODUCT REMAINED INSIDE THE PATIENT. NO PATIENT COMPLICATIONS WERE REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6321568 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K100175, P000058. One submission often covers many models, so check the product and lot details in each record.
- Z-0440-2019 · Sep 27, 2018 · TerminatedINFUSE Bone Graft X SMALL KIT REF 7510100
- Z-1593-2013 · May 28, 2013 · TerminatedINFUSE(R) Bone Graft, SMALL KIT, REF 7510200AUS, Medtronic Sofamore Danek USA, Inc., 1800 Pyramid Place, Memphis, Tennessee 38132 orthopaedic
- Z-1595-2013 · May 28, 2013 · TerminatedINFUSE(R) Bone Graft, LARGE II KIT, REF 7510800AUS, Medtronic Sofamore Danek USA, Inc., 1800 Pyramid Place, Memphis, Tennessee 38132 orthopaedic
- Z-1591-2013 · May 28, 2013 · TerminatedINFUSE(R) Bone Graft, LARGE KIT, REF 7510600, Medtronic Sofamore Danek USA, Inc., 1800 Pyramid Place, Memphis, Tennessee 38132 orthopaedic
- Z-1592-2013 · May 28, 2013 · TerminatedINFUSE(R) Bone Graft,LARGE II KIT, REF 7510800, Medtronic Sofamore Danek USA, Inc., 1800 Pyramid Place, Memphis, Tennessee 38132 orthopaedic
- Z-1594-2013 · May 28, 2013 · TerminatedINFUSE(R) Bone Graft, MEDIUM KIT, REF 7510400AUS, Medtronic Sofamore Danek USA, Inc., 1800 Pyramid Place, Memphis, Tennessee 38132 orthopaedic
- Z-1589-2013 · May 28, 2013 · TerminatedINFUSE(R) Bone Graft, SMALL KIT, REF 7510200, Medtronic Sofamore Danek USA, Inc., 1800 Pyramid Place, Memphis, Tennessee 38132 orthopaedic
- Z-1590-2013 · May 28, 2013 · TerminatedINFUSE(R) Bone Graft, MEDIUM KIT, REF 7510400, Medtronic Sofamore Danek USA, Inc., 1800 Pyramid Place, Memphis, Tennessee 38132 orthopaedic
Other Intervertebral fusion device with bone graft, lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page