N/A 7967088Recalls & reported problems

Medtronic Sofamor Danek, Inc. · SCREW DRIVER 7967088 U-JOINT 3.2MM HEX · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00613994551962), received between May 13, 2020 and Jan 2, 2025 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break1
  • Mechanical Jam1
  • Mechanics Altered1

Patient problems

  • Blood Loss1
  • Injury1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 2, 2025Break; Mechanics Altered; Break; Mechanics Altered

    INFORMATION WAS RECEIVED FROM USER FACILITY VIA MANUFACTURING REPRESENTATIVE REGARDING A PRODUCT IDENTIFIED DURING AN EVENT. IT WAS REPORTED THAT DRIVER TIP BROKE AND ISN¿T RETAINING A SCREW VERY WELL. NO PATIENT WAS INVOLVED IN THIS EVENT. NO FURTHER COMPLICATIONS WERE REPORTED/ANTICIPATED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21053040 ↗
  • InjuryMay 13, 2020Mechanical Jam; Mechanical Jam

    IT WAS REPORTED THAT THE PATIENT UNDERWENT OBLIQUE LUMBAR INTERBODY FUSION 51 DUE TO PSEUDOARTHROSIS AT L5-S1 AND BACK PAIN. REMOVAL OF THE BRANTIGAN CAGE (FROM ANOTHER MANUFACTURER) WAS PERFORMED. INTRA-OP, AFTER INSERTING THE SCREWS IN THE CAGE USING THE REPORTED DRIVER, WHEN THE DRIVER WAS BEING REMOVED, IT WAS DIFFICULT TO BE REMOVED AS ITS TIP GOT STUCK IN THE SCREW HOLE. WHEN SURGEON PULLED THE DRIVER TO REMOVE IT, THE DRIVER CAME IN CONTACT WITH THE BLADE OF THE RETRACTOR WITH A BOUNCE. AS A RESULT OF THIS, THE VEIN (THAT HAD BEEN PROTECTED BY THE RETRACTOR) HAD AN EMPTY PINHOLE OF ABOUT 1.5 MM AND THE BLEEDING OCCURRED. THE SURGEON TRIED ASTRICTION WITH THE HEMOSTATIC AGENT (TACHOCOMB). THE SURGEON ASKED FOR ASSISTANCE FROM A VASCULAR SURGERY PHYSICIAN IN THE HOSPITAL TO SEEK ADVICE WHEN THE BLEEDING HAD SUBSIDED TO SOME EXTENT. THE VASCULAR SURGERY PHYSICIAN CONFIRMED THE BLEEDING POINT AND DETERMINED THAT THERE WAS NO PROBLEM AS IT WAS, SO THE OPERATION WAS CONTINUED. AFTER THE HEMOSTATIC TREATMENT, THE WOUND CLOSURE WAS PERFORMED, AND POSTERIOR FIXATION WAS CONTINUED TO BE PERFORMED AND THE OPERATION WAS COMPLETED. THERE WAS A DELAY OF LESS THAN 60 MINUTES IN OVERALL PRO

    Patient problems: Blood Loss; Injury

    MAUDE report 10052454 ↗