ATLANTIS® Anterior Cervical Plate System 7200040Recalls & reported problems

Medtronic Sofamor Danek, Inc. · PLATE 7200040 ATL VISION ELITE 40MM · Class 2 · Implant

All models of ATLANTIS Anterior Cervical Plate System (46)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00613994625120), received between Sep 24, 2021 and Nov 22, 2023 — classified as 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Biocompatibility” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Biocompatibility1
  • Break1

Patient problems

  • Dysphagia/ Odynophagia1
  • Hypersensitivity/Allergic reaction1
  • No Clinical Signs, Symptoms or Conditions1
  • Swelling/ Edema1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 22, 2023Biocompatibility; Biocompatibility

    INFORMATION WAS RECEIVED FROM A PATIENT, COMPETENT AUTHORITY VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH FUSION THERAPY. IT WAS REPORTED THAT THE PATIENT HAD A ATLANTIS C5-7 ANTERIOR FUSION PLATE PLACED FOR DISCS PROTRUDING ONTO SPINAL CORD. PATIENT DEVELOPED AUTOINFLAMMATORY DISORDER, ERYTHRODERMA SWELLING AND EDEMA IN TISSUES AND SKIN WHICH HAS NOT RESOLVED AND FOUND TO BE ALLERGIC TO TWO OF THE IMPLANT METALS - NICKEL AND TITANIUM. THERE WAS ALSO LOCAL SWELLING CAUSING DYSPHAGIA AND ABNORMAL SWELLING AND THICKENING OF TISSUE IN FRONT OF THE DEVICE BEHIND THE UPPER ESOPHAGUS ON CT SCAN. THERE WAS NO PREOP COUNSELLING ON METAL ALLERGY OR GUIDANCE ON PREOP METAL PATCH TESTING. THE PLATE WAS REMOVED. PLATE AND SCREWS WERE PLANNED FOR REMOVAL DUE EFFECTS OF SYSTEMIC METAL ALLERGY TO THE DEVICE COMPONENTS CAUSING LOCAL AND SYSTEMIC ALLERGIC REACTION WITH MULTIORGAN IMPAIRMENT. PREOP IMAGING SHOWED A BROKEN FIXATION SCREW IN THE C7 VERTEBRA AND PERIOPERATIVELY AFTER THE PLATE WAS REMOVED. THE FUSION WAS FOUND TO BE MOBILE - IE THE C5-7 FUSION HAD FAILED AND MY CERVICAL SPINE IS NOW UNSTABLE. THE BROKEN SCREW WILL HAVE CONTRIBUTED TO FUSION FAILURE. THE BROKEN SCREW HAD

    Patient problems: Dysphagia/ Odynophagia; Hypersensitivity/Allergic reaction; Swelling/ Edema

    MAUDE report 18189162 ↗
  • MalfunctionSep 24, 2021Break; Break

    THE INFORMATION WAS RECEIVED FROM COMPETENT AUTHORITY VIA A MANUFACTURING REPRESENTATIVE REGARDING A PATIENT WITH MIXED CERVICAL SPO NDYLOPATHY FOR ANTERIOR CERVICAL ACDF SPINAL THERAPY. IT WAS REPORTED THAT ELITE LOCKING RING WAS BROKEN. THERE WAS NO PATIENT SYMPTOMS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12524391 ↗

Other APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices

All APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices →