Protecta™ XT VR D314VRMRecalls & reported problems
Medtronic, Inc. · ICD D314VRM PROTECTA XT VR US MR DF4 · Class 3 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
Quick summary
This Medtronic Protecta XT VR D314VRM is an implantable cardioverter defibrillator, a device placed under the skin to watch the heart rhythm and shock it when needed. The 64 reports mostly describe the device giving shocks or pacing for rhythms that were not actually there, sensing problems, and batteries running down early or overheating. No deaths were reported, and 50 reports involved injuries. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 64
- Deaths reported
- 0
- Injuries reported
- 50
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 64 adverse event reports that list this exact device (DI 00613994714596), received between Feb 9, 2017 and May 6, 2023 — classified as 50 injuries, 14 malfunctions.
The most frequently reported specific device problem is “Inappropriate/Inadequate Shock/Stimulation” (18 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Inappropriate/Inadequate Shock/Stimulation18
- Adverse Event Without Identified Device or Use Problem15
- Device Sensing Problem14
- Premature Discharge of Battery9
- Invalid Sensing7
- Over-Sensing4
- Battery Problem3
- Electromagnetic Interference3
Patient problems
- Shock from Patient Lead(s)18
- No Known Impact Or Consequence To Patient17
- Unspecified Infection9
- No Clinical Signs, Symptoms or Conditions7
- Endocarditis3
- No Consequences Or Impact To Patient3
- Tachycardia2
- Atrial Fibrillation1
Recent adverse event reports
The 25 most recent of 64 reports, in the reporter's own words as published by the FDA.
InjuryMay 6, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT WAS ADMITTED TO THE EMERGENCY ROOM (ER) WITH SYNCOPE. THE DEVICE WAS NOTED TO BE OVERHEATING. THE DEVICE ALERTED FOR RECOMMENDED REPLACEMENT TIME (RRT) AND HAD LOW BATTERY VOLTAGE WITH AN END OF SERVICE (EOS) MESSAGE. THE DEVICE WAS REMOVED AND A NEW DEVICE WAS IMPLANTED. IT WAS FURTHER REPORTED THAT THE RIGHT VENTRICULAR (RV) LEAD ALERTED FOR HIGH PACING IMPEDANCE. THE LEAD REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Syncope/Fainting
MAUDE report 16882819 ↗InjuryJan 23, 2023Battery Problem; Appropriate Device Problem Term/Code Not Available; Battery Problem; Appropriate Device Problem Term/Code Not Available
IT WAS FURTHER REPORTED VIA FOLLOW-UP THAT THE DEVICE BATTERY WAS AT ELECTIVE REPLACEMENT INDICATOR (ERI) STATUS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16225702 ↗InjuryDec 7, 2022Failure to Charge; Failure to Charge
IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) IS MONTHS PAST END OF SERVICE (EOS) AND HAS HAD A CHARGE CIRCUIT TIMEOUT. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15933483 ↗InjuryNov 22, 2022Pacing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Pacing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem
IT WAS REPORTED THAT THE INTERROGATION REPORT SHOWED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) HAD DELIVERED ANTI-TACHYC ARDIA PACING (ATP) FOR AN EPISODE OF VENTRICULAR FIBRILLATION (VF), AND ALSO TREATED WITH SHOCKS. IT WAS SUSPECTED THAT THE RHYTHM WAS SUPRA VENTRICULAR TACHYCARDIA (SVT), AND THERAPY WAS INITIALLY WITHHELD, HOWEVER, IT WAS SUSPECTED THAT THE VENTRICULAR FIBRILLATION (VF) WAS STILL SUPRA VENTRICULAR TACHYCARDIA (SVT) AND THERAPIES WERE THEREFORE INAPPROPRIATE. THE DEVICE REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Shock from Patient Lead(s)
MAUDE report 15847789 ↗MalfunctionJul 20, 2022Device Sensing Problem; Device Sensing Problem
IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) DETECTED SUPERIOR VENA CAVA (SVC) WHEN THE RHYTHM WAS VENTRICULAR TACHYCARDIA (VT) DUE TO ONSET. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15064798 ↗InjuryJun 17, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT WAS HOSPITALIZED DUE TO ENDOCARDITIS AND THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) SYSTEM WAS REMOVED DUE TO A BACTERIAL INFECTION. ANTIBIOTICS WERE ADMINISTERED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Bacterial Infection; Chills; Diarrhea; Endocarditis
MAUDE report 14735509 ↗InjuryMay 20, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) SYSTEM WAS REMOVED DUE TO METHICILLIN-RESISTANT STAPHYLOCOCCUS AUREUS (MRSA) INFECTION. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Drug Resistant Bacterial Infection
MAUDE report 14457368 ↗InjuryMay 9, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) SYSTEM WAS REMOVED DUE TO AN INFECTION. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 14342749 ↗MalfunctionApr 29, 2022Device Alarm System; Device Alarm System
IT WAS REPORTED THAT THE HEALTHCARE PROVIDER COULD NOT HEAR THE ALERT TONES FROM THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) WHEN DEMONSTRATING TONES TO THE PATIENT. THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14251973 ↗InjuryApr 18, 2022Reset Problem; Reset Problem
IT WAS REPORTED BY THE HEALTH CARE PROFESSIONAL (HCP) THAT DURING THE PATIENT'S INTERNALLY DELIVERED CARDIOVERSION, THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) EXPERIENCED A POWER ON RESET (POR). THE DEVICE REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14136060 ↗InjuryMar 8, 2022Failure to Deliver Shock/Stimulation; Device Sensing Problem; Failure to Deliver Shock/Stimulation; Device Sensing Problem
IT WAS REPORTED THAT THE PATIENT RECEIVED POTENTIAL INAPPROPRIATE THERAPY FOR SUPRA VENTRICULAR TACHYCARDIA (SVT) IN THE VENTRICULAR TACHYCARDIA (VT) ZONE. THE DEVICE WAVELET WAS ATTEMPTING TO WITHHOLD. THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Tachycardia
MAUDE report 13693442 ↗InjuryDec 22, 2021Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem
IT WAS REPORTED THAT THE PATIENT RECEIVED INAPPROPRIATE THERAPY DUE TO ATRIAL FIBRILLATION (AF) WITH RAPID VENTRICULAR RESPONSE (RVR), WHICH WAS DETECTED AS VENTRICULAR FIBRILLATION (VF). THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Shock from Patient Lead(s)
MAUDE report 13062003 ↗MalfunctionDec 7, 2021Device Sensing Problem; Device Sensing Problem
IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) DETECTED SVT (SUPRA VENTRICULAR TACHYCARDIA) WHEN IT IS BELIEVED TO BE A REAL VT (VENTRICULAR TACHYCARDIA) EPISODE. THE ICD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12954060 ↗InjuryNov 12, 2021Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem
IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) DETECTED VENTRICULAR FIBRILLATION (VF) AND SHOCKED THE PATIENT. IT WAS SUSPECTED THAT THE RHYTHM WAS SUPRA VENTRICULAR TACHYCARDIA (SVT). THE DEVICE WAS EXPLANTED AND REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Shock from Patient Lead(s)
MAUDE report 12804632 ↗InjuryNov 7, 2021Failure to Deliver Shock/Stimulation; Device Sensing Problem; Failure to Deliver Shock/Stimulation; Device Sensing Problem
IT WAS REPORTED THAT THERAPY WAS INAPPROPRIATELY WITHHELD FOR AN EPISODE OF VENTRICULAR TACHYCARDIA (VT) THAT WAS DETECTED BY THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) AS T-WAVE OVERSENSING (TWOS). THE PATIENT'S MEDICATION WAS ADJUSTED AND THE ICD REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Tachycardia
MAUDE report 12759697 ↗InjuryOct 7, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) WAS EXPLANTED DUE TO A POCKET INFECTION. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 12593199 ↗InjurySep 28, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) SYSTEM WAS EXPLANTED DUE TO VEGETATION ON A CARDIAC VALVE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 12540488 ↗InjuryAug 23, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT DEVELOPED SUBACUTE BACTERIAL ENDOCARDITIS AND WAS TREATED WITH INTRAVENOUS ANTIBIOTICS. THE IMPLANT ABLE CARDIOVERTER DEFIBRILLATOR (ICD) SYSTEM REMAINS IMPLANTED. THE PATIENT IS A PARTICIPANT IN A CLINICAL STUDY. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 12354277 ↗InjuryJul 27, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) WAS REMOVED DUE TO A BACTEREMIC STREP INFECTION. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 12232804 ↗InjuryDec 30, 2020Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem; Inappropriate/Inadequate Shock/Stimulation; Device Sensing Problem
IT WAS REPORTED THAT THE PATIENT WAS INAPPROPRIATELY SHOCKED BY THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) FOR DETECTING AN SUPRA VENTRICULAR TACHYCARDIA (SVT) ARRHYTHMIA AS A VENTRICULAR TACHYCARDIA (VT) EPISODE. THE DEVICE WAS REPROGRAMMED AND REMAINS IN USE. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Shock from Patient Lead(s)
MAUDE report 11097644 ↗MalfunctionNov 17, 2020Signal Artifact/Noise; Electromagnetic Interference; Over-Sensing; Low impedance; Signal Artifact/Noise; Electromagnetic Interference; Over-Sensing; Low impedance
IT WAS REPORTED THAT A LEAD ALERT HAD TRIGGERED DUE TO A ZERO IMPEDANCE MEASUREMENT ON THE RIGHT VENTRICULAR (RV) LEAD. IT WAS NOTED THAT THE PATIENT WAS HAVING A MEDICAL PROCEDURE AT THE TIME OF THE ISSUE. THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10852666 ↗MalfunctionOct 20, 2020Electromagnetic Interference; Electromagnetic Interference
IT WAS REPORTED THAT THE PATIENT HEARD TWO "SOLID" ALERT TONES COMING FROM THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD). REMOTE MONITORING TRANSMISSION INDICATED THAT NO ALERT CRITERIA HAD BEEN MET. IT WAS SUSPECTED THAT THE PATIENT HAD A MAGNET EXPOSURE. THEICD REMAINS IN USE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10707836 ↗InjurySep 2, 2020Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT THE PATIENT COMPLAINED OF PAIN AT THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) POCKET. THE ICD WAS EXPLANTED AND THE ASSOCIATED RIGHT VENTRICULAR (RV) LEAD CAPPED. THE SYSTEM WILL NOT BE REPLACED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Pain
MAUDE report 10482948 ↗InjuryJul 23, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT HAD DEVELOPED AN INFECTION AND THEIR IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) AND RIGHT VENTRICULAR (RV) LEAD HAVE BEEN EXTRACTED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Unspecified Infection
MAUDE report 10314736 ↗MalfunctionJun 30, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE CALLER QUESTIONED WHY THE DEVICE "DID NOT WORK THIS TIME WHEN IT WORKED BEFORE". THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD) WAS EXPLANTED. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10212567 ↗
Other Implantable cardioverter defibrillator (non-CRT) devices
- EMBLEM™ MRI S-ICD A219Boston Scientific Corporation · Implantable cardioverter defibrillator (non-CRT)2 recalls36 deaths15,404 reports
- EMBLEM™ S-ICD A209Boston Scientific Corporation · Implantable cardioverter defibrillator (non-CRT)1 recall7 deaths6,788 reports
- EMBLEM™ S-ICD 3501Boston Scientific Corporation · Implantable cardioverter defibrillator (non-CRT)7 deaths4,936 reports
- Cobalt™ XT DR MRI SureScan™ DDPA2D4Medtronic, Inc. · Implantable cardioverter defibrillator (non-CRT)3 recalls30 deaths1,603 reports
- ENDOTAK RELIANCE® G 0185Boston Scientific Corporation · Implantable cardioverter defibrillator (non-CRT)9 deaths1,632 reports
- VIGILANT™ EL ICD DR D233Boston Scientific Corporation · Implantable cardioverter defibrillator (non-CRT)9 deaths1,563 reports
- Evera MRI™ XT DR SureScan® DDMB1D4Medtronic, Inc. · Implantable cardioverter defibrillator (non-CRT)1 recall35 deaths1,426 reports
- Durata™ 7122St. Jude Medical, Inc. · Implantable cardioverter defibrillator (non-CRT)27 deaths1,377 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page