Medtronic Sofamor Danek, Inc. · RACK 9411905 19 22 25MM E · Class 2

All models of Medtronic Reusable Instruments (34)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00613994730107), received between Mar 25, 2021 and Mar 25, 2021 — classified as 2 injuries.

The most frequently reported specific device problem is “Material Deformation” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Material Deformation2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 25, 2021Material Deformation; Material Deformation

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROFESSIONAL VIA MANUFACTURING REPRESENTATIVE REGARDING PATIENT WITH L3/4 VERTEBRAL BODY COLLAPSE SUGGESTED FOR SPINAL THERAPY. POSTERIOR FIXATION WAS PERFORMED AT L1-S2. LEVELS IMPLANTED WAS L3- 4. EVENT OCCURRED INTRA-OP. IT WAS REPORTED THAT L3/4 VERTEBRAL SUBTOTAL REMOVAL WAS PERFORMED AND THE REPORTED IMPLANTS WERE PLACED. THE CAGE WAS LENGTHENED AFTER BEING INSERTED BETWEEN THE VERTEBRAL BODIES, BUT IT SHRANK BEFORE IT WAS FULLY LENGTHENED. WHEN THE CAGE WAS CHECKED OUTSIDE THE OPERATIVE FIELD, IT COULD BE LENGTHENED TO THE END WITHOUT ANY PROBLEM, BUT THE SAME EVENT WAS CONFIRMED IN THE OPERATIVE FIELD. IT WAS ATTEMPTED TO LENGTHEN THE CAGE BY INSERTING AN ADJUSTER INTO THE OPENING FOR FILLING BONE GRAFT, BUT THE CAGE COULDN'T BE LENGTHENED UNTIL THE END. THEREFORE, THE CAGE WAS REPLACED WITH ANOTHER ONE WITH ONE INCREASED SIZE. THE TORQUE LIMITING DRIVER WAS NOT USED. DELAY OF OVER 60 MINUTES WAS REPORTED. IMPLANT WAS EXPLANTED AND BEING RETURNED. NO PATIENT SYMPTOMS OR FURTHER COMPLICATIONS WAS REPORTED. NO DEFECT WAS FOUND IN INSERTER IN APPEARANCE. LOT#CA12G066 AND CA12J027 OF PINION DRIVER HAD SCRATCHES AT TIP. CA13F029-B HAD SCR

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11567361 ↗
  • InjuryMar 25, 2021Material Deformation; Material Deformation

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROFESSIONAL VIA MANUFACTURING REPRESENTATIVE REGARDING PATIENT WITH L3/4 VERTEBRAL BODY COLLAPSE SUGGESTED FOR SPINAL THERAPY. POSTERIOR FIXATION WAS PERFORMED AT L1-S2. LEVELS IMPLANTED WAS L3- 4. EVENT OCCURRED INTRA-OP. IT WAS REPORTED THAT L3/4 VERTEBRAL SUBTOTAL REMOVAL WAS PERFORMED AND THE REPORTED IMPLANTS WERE PLACED. THE CAGE WAS LENGTHENED AFTER BEING INSERTED BETWEEN THE VERTEBRAL BODIES, BUT IT SHRANK BEFORE IT WAS FULLY LENGTHENED. WHEN THE CAGE WAS CHECKED OUTSIDE THE OPERATIVE FIELD, IT COULD BE LENGTHENED TO THE END WITHOUT ANY PROBLEM, BUT THE SAME EVENT WAS CONFIRMED IN THE OPERATIVE FIELD. IT WAS ATTEMPTED TO LENGTHEN THE CAGE BY INSERTING AN ADJUSTER INTO THE OPENING FOR FILLING BONE GRAFT, BUT THE CAGE COULDN'T BE LENGTHENED UNTIL THE END. THEREFORE, THE CAGE WAS REPLACED WITH ANOTHER ONE WITH ONE INCREASED SIZE. THE TORQUE LIMITING DRIVER WAS NOT USED. DELAY OF OVER 60 MINUTES WAS REPORTED. IMPLANT WAS EXPLANTED AND BEING RETURNED. NO PATIENT SYMPTOMS OR FURTHER COMPLICATIONS WAS REPORTED. NO DEFECT WAS FOUND IN INSERTER IN APPEARANCE. LOT#CA12G066 AND CA12J027 OF PINION DRIVER HAD SCRATCHES AT TIP. CA13F029-B HAD SCR

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11567353 ↗

FDA clearance and classification

Cleared through 510(k) K100976 on Oct 21, 2010 (decision: Substantially Equivalent). Submitted by Medtronic Sofamor Danek USA, Inc. as “T2 Xvbr 1.5 Spinal System”. The FDA review took 196 days. FDA record ↗

The FDA regulates product code MQP (spinal vertebral body replacement device) under 21 CFR 888.3060 as a Class II device. 21 CFR 888.3060 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Medtronic Reusable Instruments 9411905

Has the Medtronic Reusable Instruments 9411905 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00613994730107), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Medtronic Reusable Instruments 9411905?

The FDA's MAUDE database lists 2 adverse event reports for this device, received on Mar 25, 2021. In those reports, the most common specific device problem is “Material Deformation” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Medtronic Reusable Instruments 9411905?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Medtronic Reusable Instruments 9411905 FDA approved?

It was cleared through 510(k) K100976 on Oct 21, 2010. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Medtronic Reusable Instruments 9411905, and is it still sold?

The FDA's device database lists Medtronic Sofamor Danek, Inc. as the company responsible for it (brand Medtronic Reusable Instruments, model 9411905). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices

All SPINAL VERTEBRAL BODY REPLACEMENT DEVICE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page