Medtronic, Inc. · CATHETER LA6JR35 LA 6F 100CM JR35 · Class 2
All models of Launcher (64)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00613994817723), received between Aug 11, 2017 and Oct 28, 2021 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Component or Accessory Incompatibility” (1 report).
52 other recalls cover devices cleared under the same FDA submission (K021256); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Component or Accessory Incompatibility1
- Device Expiration Issue1
- Material Deformation1
- Material Distortion1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient1
- Patient Problem/Medical Problem1
- Vascular Dissection1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 28, 2021Use of Device Problem; Use of Device Problem
IT WAS REPORTED THAT ONE 6F LAUNCHER GUIDE CATHETER WAS EXPIRED. NO PATIENT INJURY REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12710656 ↗MalfunctionApr 8, 2021Material Deformation; Material Deformation
DURING A PROCEDURE, AN ATTEMPT WAS MADE TO USE ONE 6 FRENCH LAUNCHER GUIDE CATHETER TO TREAT A LESION. THERE WAS NO DAMAGE NOTED TO THE PACKAGING. THE DEVICE WAS REMOVED FROM PACKAGING PER IFU WITH NO ISSUES NOTED. EXCESSIVE FORCE WAS NOT USED DURING INSERTION/DELIVERY. IT WAS REPORTED THAT THE CATHETER KINKED WHILE IN THE PATIENT. THE DEVICE WAS NOT EXCESSIVELY TORQUED OR EXCESSIVE FORCE WAS NOT USED. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11633365 ↗InjuryJan 31, 2018Component or Accessory Incompatibility; Material Distortion; Component or Accessory Incompatibility; Material Distortion
THE PHYSICIAN INTENDED TO USE A 6F LAUNCHER GUIDE CATHETER. THERE WAS NO DAMAGE NOTED TO THE DEVICE PACKAGING. THE DEVICE WAS REMOVED FROM THE PACKAGING PER IFU. THE DEVICE WAS INSPECTED WITH NO ISSUES. THE DEVICE WAS PREPPED PER IFU WITH NO ISSUES. THE DEVICE WAS NOT EXCESSIVELY TORQUED. THE PROXIMAL RIGHT RADIAL ARTERY WAS THE ACCESS SITE. THE ARTERY WAS NON-TORTUOUS AND NON-CALCIFIED. NO RESISTANCE WAS NOTED WHEN INSERTING THE INTRODUCER. RESISTANCE WAS EXPERIENCED WHEN INSERTING THE CATHETER THROUGH THE 6F NON-MDT INTRODUCER, WITH ANOTHER DEVICE INSERTED THROUGH THE LUMEN OF THE GUIDE CATHETER. THE CATHETER WAS USED ON A TEFLON GUIDEWIRE AND A UNIDIRECTIONAL VALVE. IT IS REPORTED THAT AT THE MOMENT OF THE TRANSITION FROM THE INTRODUCER TO THE CATHETER THE PHYSICIAN FELT RESISTANCE OF THE PROXIMAL RADIAL ARTERY. EXCESSIVE FORCE WAS NOT USED DURING DELIVERY. THE PHYSICIAN TRIED ONCE TO ROTATE THE LAUNCHER DEVICE TO SEE IF IT WOULD MOVE BETTER, BUT IT DID NOT WORK AND DISSECTION OF THE PROXIMAL THIRD OF THE FOREARM OCCURRED. THE CATHETER WAS REMOVED AND IT WAS NOTED THAT THE TIP WAS DEFORMED- THE TIP WAS IRREGULAR. NO PORTION OF THE CATHETER WAS DETACHED. TO TREAT THE DISSECTION,
Patient problems: Patient Problem/Medical Problem; Vascular Dissection
MAUDE report 7232309 ↗MalfunctionAug 11, 2017Device Expiration Issue; Device Expiration Issue
THE LAUNCHER GUIDE CATHETER WAS USED APPROX 5 DAYS PAST ITS EXPIRY DATE. PATIENT IS WELL. DEVICE DISCARDED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6787898 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K021256. One submission often covers many models, so check the product and lot details in each record.
- Z-1245-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100 cmJL 3.5 Model Number: LA6JL35
- Z-1246-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100 cm JR 4.0 Model Number: LA6JR40
- Z-1248-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100 cm EBU 3.0 Model Number: LA6EBU30
- Z-1247-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100cm EBU 3.75 Model Number: LA6EBU375
- Z-0205-2015 · Oct 13, 2014 · TerminatedMedtronic Launcher Coronary Guide Catheter; MODEL: LA6JR40K
- Z-1564-2013 · Jun 12, 2013 · TerminatedMedtronic, Launcher Guiding Catheter, Model # LA8EBU45SH, Lot # 0006722866, 8F and Model # LA6IMAD, Lot # 0006724224, 6F Product Usage: The Medtronic Guiding Catheter is designe
- Z-0967-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F SR6.0 LAUNCHER CATHETER LA6SR60 LA 6F 100CM SR60 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
- Z-0999-06 · Apr 5, 2006 · TerminatedCATHETER SA6SR40 SA 6F 100CM Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are introduced into the coronary or perip
- Z-0943-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F EBU4.0 110CM LA CATHETER LA6EBU40A LA 6F 110CM EB40 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-0964-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F SR4.5 W/SH LAUN CATHETER LA6SR45SH LA 6F 100CM SR45 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-0945-06 · Apr 5, 2006 · TerminatedCATHETER LA6HSIA 6F 110CM HSI Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are introduced into the coronary or perip
- Z-0996-06 · Apr 5, 2006 · TerminatedCATHETER SA63DRC SA 6F 100CM 3 CATHETER SA63DRC SA 6F 100CM 3DRC Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are in
- Z-0944-06 · Apr 5, 2006 · TerminatedCATH GUIDE 6F LAUNCHER EBU 4.5 CATHETER LA6EBU45A LA 6F 110CM EB45 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-0951-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F JL5.0 110CM LAU CATHETER LA6JL50A LA 6F 110CM JL50 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are i
- Z-1006-06 · Apr 5, 2006 · TerminatedCATHETER SB6SR40 SB 6F 100CM S CATHETER SB6SR40 SB 6F 100CM SR40 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are in
…and 37 more.
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗