Launcher LA6AR20SHRecalls & reported problems
Medtronic, Inc. · CATHETER LA6AR20SH LA 6F 100CM AR20 · Class 2
All models of Launcher (64)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00613994819772), received between May 15, 2019 and May 15, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Deformation” (1 report).
52 other recalls cover devices cleared under the same FDA submission (K021256); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Deformation1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 15, 2019Material Deformation; Material Deformation
THE PHYSICIAN WAS USING A RESOLUTE INTEGRITY DEVICE AND A LAUNCHER GUIDE CATHETER TO TREAT A LESION IN THE MID RIGHT CORONARY ARTERY (RCA). THE LESION WAS MODERATELY TORTUOUS AND MODERATELY CALCIFIED WITH 80% STENOSIS. THERE WERE NO ABNORMALITIES REPORTED IN RELATION TO THE PATIENT¿S ANATOMY. NO ISSUES WERE NOTED TO THE DEVICE¿S PACKAGING, NO ISSUES WERE NOTED WHEN REMOVING THE RESOLUTE INTEGRITY FROM THE HOOP/TRAY. THE RESOLUTE INTEGRITY DEVICE WAS INSPECTED WITH NO ISSUES. THE LAUNCHER DEVICE WAS NOT INSPECTED. THE LAUNCHER DEVICE WAS REMOVED FROM THE PACKAGING AND PREPPED PER THE IFU. NEGATIVE PREP WAS PERFORMED ON THE RESOLUTE INTEGRITY DEVICE WITH NO ISSUES NOTED. THE LESION WAS PRE-DILATED, THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. RESISTANCE WAS NOT ENCOUNTERED HOWEVER EXCESSIVE FORCE WAS USED. IT WAS STATED THAT THE LAUNCHER WAS EXCESSIVELY TORQUED. IT WAS REPORTED THAT THE LAUNCHER BECAME TWISTED WHEN TURNING THE RIGHT SUBCLAVIAN ARTERY AND AS THE RESOLUTE INTEGRITY DEVICE WAS INSIDE THE LAUNCHER IT ALSO BECAME DEFORMED/TWISTED AT THE CATHETER/DELIVERY SYSTEM. IT WAS REPORTED THAT THE PHYSICIAN THINKS THAT THE EVENT WAS DUE TO THE USE OF THE DEVICE¿S IN
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8611670 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K021256. One submission often covers many models, so check the product and lot details in each record.
- Z-1245-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100 cmJL 3.5 Model Number: LA6JL35
- Z-1246-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100 cm JR 4.0 Model Number: LA6JR40
- Z-1247-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100cm EBU 3.75 Model Number: LA6EBU375
- Z-1248-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100 cm EBU 3.0 Model Number: LA6EBU30
- Z-0205-2015 · Oct 13, 2014 · TerminatedMedtronic Launcher Coronary Guide Catheter; MODEL: LA6JR40K
- Z-1564-2013 · Jun 12, 2013 · TerminatedMedtronic, Launcher Guiding Catheter, Model # LA8EBU45SH, Lot # 0006722866, 8F and Model # LA6IMAD, Lot # 0006724224, 6F Product Usage: The Medtronic Guiding Catheter is designe
- Z-0945-06 · Apr 5, 2006 · TerminatedCATHETER LA6HSIA 6F 110CM HSI Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are introduced into the coronary or perip
- Z-0952-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F JR4.0 110CM LAU CATHETER LA6JR40A LA 6F 110CM JR40 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are i
- Z-1006-06 · Apr 5, 2006 · TerminatedCATHETER SB6SR40 SB 6F 100CM S CATHETER SB6SR40 SB 6F 100CM SR40 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are in
- Z-0944-06 · Apr 5, 2006 · TerminatedCATH GUIDE 6F LAUNCHER EBU 4.5 CATHETER LA6EBU45A LA 6F 110CM EB45 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-1005-06 · Apr 5, 2006 · TerminatedCATHETER SB6SR35SH SB 6F 100CM Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are introduced into the coronary or peri
- Z-0956-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F SR3.0 LAUNCHER CATHETER LA6SR30 LA 6F 100CM SR30 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
- Z-0942-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F EBU3.5 110CM LA CATHETER LA6EBU35A LA 6F 110CM EB35 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-0967-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F SR6.0 LAUNCHER CATHETER LA6SR60 LA 6F 100CM SR60 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
- Z-0937-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F 3DRC LAUNCHER CATHETER LA63DRC LA 6F 100CM 3DRC Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are intro
…and 37 more.
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page