Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00613994821393), received between Mar 11, 2021 and Mar 11, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).
52 other recalls cover devices cleared under the same FDA submission (K021256); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component1
- Material Deformation1
Patient problems
- Unspecified Tissue Injury1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 11, 2021Detachment of Device or Device Component; Material Deformation; Detachment of Device or Device Component; Material Deformation
DURING A PROCEDURE, AN ATTEMPT WAS MADE TO USE ONE 6 FRENCH GUIDE CATHETER TO TREAT A NON-TORTUOUS, NON-CALCIFIED LESION WITH NO STENOSIS LOCATED IN THE FEMORAL ARTERY. THE TAKEOFFS WERE ABNORMAL SO DIFFERENT GUIDES WERE USED TO TRY AND ENGAGE THE ARTERY. A RADIAL APPROACH WAS ORIGINALLY PLANNED, HOWEVER IT WAS SWITCHED TO A FEMORAL APPROACH. THERE WAS NO DAMAGE NOTED TO THE PACKAGING. THE DEVICE WAS REMOVED FROM PACKAGING AND PREPPED PER IFU WITH NO ISSUES NOTED. THE DEVICE WAS NOT INSPECTED. EXCESSIVE FORCE WAS NOT USED DURING INSERTION/DELIVERY. IT WAS REPORTED THAT THE LEFT CORONARY ARTERY COULD NOT BE ENGAGED AND RESISTANCE WAS ENCOUNTERED DURING REMOVAL OF THE GUIDE CATHETER. IT WAS STATED THAT THE GUIDE CATHETER WAS TORQUED AND COUNTER TORQUED. DURING AN X-RAY THE CATHETER WAS OBSERVED TO HAVE BROKEN IN HALF AND WAS STUCK IN THE SHEATH. A CUT DOWN WAS PERFORMED TO REMOVE THE DEVICE. THE PATIENT WAS REPORTED TO BE ALIVE WITH NO FURTHER INJURIES.
Patient problems: Unspecified Tissue Injury
MAUDE report 11459703 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K021256. One submission often covers many models, so check the product and lot details in each record.
- Z-1247-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100cm EBU 3.75 Model Number: LA6EBU375
- Z-1245-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100 cmJL 3.5 Model Number: LA6JL35
- Z-1246-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100 cm JR 4.0 Model Number: LA6JR40
- Z-1248-2021 · Jan 15, 2021 · TerminatedMedtronic 6F Launcher Guide Catheter 100 cm EBU 3.0 Model Number: LA6EBU30
- Z-0205-2015 · Oct 13, 2014 · TerminatedMedtronic Launcher Coronary Guide Catheter; MODEL: LA6JR40K
- Z-1564-2013 · Jun 12, 2013 · TerminatedMedtronic, Launcher Guiding Catheter, Model # LA8EBU45SH, Lot # 0006722866, 8F and Model # LA6IMAD, Lot # 0006724224, 6F Product Usage: The Medtronic Guiding Catheter is designe
- Z-0966-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F SR5.0 W/SH LAUN CATHETER LA6SR50SH LA 6F 100CM SR50 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-0937-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F 3DRC LAUNCHER CATHETER LA63DRC LA 6F 100CM 3DRC Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are intro
- Z-1007-06 · Apr 5, 2006 · TerminatedCATHETER SB6SR40SH SB 6F 100CM Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are introduced into the coronary or peri
- Z-0954-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F JR5.0 110CM LAU CATHETER LA6JR50A LA 6F 110CM JR50 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are i
- Z-0967-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F SR6.0 LAUNCHER CATHETER LA6SR60 LA 6F 100CM SR60 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
- Z-0939-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F AL 1.0 110CM LA CATHETER LA6AL10A LA 6F 110CM AL10 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are i
- Z-1001-06 · Apr 5, 2006 · TerminatedCATHETER SB63DRC SB 6F 100CM 3 CATHETER SB63DRC SB 6F 100CM 3DRC Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are in
- Z-0948-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 6F JL4.0 110CM LAU CATHETER LA6JL40A LA 6F 110CM JL40 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are i
- Z-0945-06 · Apr 5, 2006 · TerminatedCATHETER LA6HSIA 6F 110CM HSI Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are introduced into the coronary or perip
…and 37 more.
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page