Skip to content

SHERPA NX BALANCED SB6AL20Recalls & reported problems

Medtronic, Inc. · CATHETER SB6AL20 SB 6F 100CM AL20 · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00613994826923), received between Jan 14, 2021 and Jan 14, 2021 — classified as 1 malfunction.

The most frequently reported specific device problem is “Material Deformation” (1 report).

191 other recalls cover devices cleared under the same FDA submission (K042489); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 14, 2021Material Deformation; Material Deformation

    DURING A PROCEDURE PROMOTED BY STEMI, AN ATTEMPT WAS MADE TO USE ON SHERPA GUIDE CATHETER TO TREAT A LESION. THE DEVICE WAS INSPECTED AND PREPPED PER IFU WITH NO ISSUES NOTED. EXCESSIVE FORCE WAS USED AND THE DEVICE WAS EXCESSIVELY TORQUED. IT WAS REPORTED THAT THE CATHETER WAS OVER TORQUED AND KINKED WHILE IN THE PATIENT. THE KINK WAS SO SEVERE, THE CATHETER WOULD NOT PASS BACK THROUGH NON-MEDTRONIC SHEATH AND THE GUIDE CATHETER HAD TO BE REMOVED. THE DEVICE WAS REPLACED WITH A 7F SYSTEM FOR INCREASED SUPPORT. NO PATIENT INJURY WAS REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11169228 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K042489. One submission often covers many models, so check the product and lot details in each record.

  • Z-2701-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F CHAMP2.0 SH, .070", REF SA6CHAMP20SH. for cardiovascular use
  • Z-2573-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F, CHAMP0.5, 100CM.070", REF SA6CHAMP05. for cardiovascular use
  • Z-2667-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F RBU4.5, .070", REF SA6RBU45. for cardiovascular use
  • Z-2608-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F, SR4.0, 100CM, 070", REF SA6SR40. for cardiovascular use
  • Z-2676-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F MAC3.5 SH, .070", REF SA6MAC35SH. for cardiovascular use
  • Z-2634-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F SL3.5, .070", REF SA6SL35. for cardiovascular use
  • Z-2718-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F ERAD LEFT, SHORT TIP, .070", REF SA6ERADLST. for cardiovascular use
  • Z-2654-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F CHAMP1.0, .070", REF SA6CHAMP10. for cardiovascular use
  • Z-2705-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F SAL1.0 SH, .070", REF SA6SAL10SH. for cardiovascular use
  • Z-2731-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F ECR4.0, .070", REF SA6ECR40. for cardiovascular use
  • Z-2601-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F, PK1, 47CM, 070", REF SA6PK1W. for cardiovascular use
  • Z-2735-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F LCB SH, .070", REF SA6LCBSH. for cardiovascular use
  • Z-2694-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F MAC3.0 30o, .070", REF SA6MAC3030. for cardiovascular use
  • Z-2741-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F SAL1.5, .070", REF SA6SAL15. for cardiovascular use
  • Z-2696-2019 · Mar 15, 2019 · Terminated
    SHERPA NX ACTIVE GUIDING CATHETER, 6F JL6.0 SH, .070", REF SA6JL60SH. for cardiovascular use

…and 176 more.

Other CATHETER, PERCUTANEOUS devices

All CATHETER, PERCUTANEOUS devices →

Sources and updates