Launcher LA7JL35SHRecalls & reported problems
Medtronic, Inc. · CATHETER LA7JL35SH LA 7F 100CM JL35 · Class 2
All models of Launcher (64)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00613994832054), received between Jun 25, 2018 and Jun 25, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Material Deformation” (1 report).
13 other recalls cover devices cleared under the same FDA submission (K022764); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Material Deformation1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 25, 2018Material Deformation; Material Deformation
A 7F LAUNCHER GUIDE CATHETER WAS INTENDED TO BE USED TO TREAT A SEVERELY TORTUOUS, MODERATELY CALCIFIED LESION IN THE DISTAL LAD. THERE WAS NO DAMAGE NOTED TO THE DEVICE PACKAGING. THE DEVICE WAS REMOVED FROM THE PACKAGING WITH NO ISSUES. THE DEVICE WAS INSPECTED WITH ISSUES. IT IS REPORTED THAT THE MID-SECTION CATHETER BECAME BADLY DAMAGED AND KINKED WHILE IN THE PATIENT. RESISTANCE WAS ENCOUNTERED WHEN ADVANCING THE DEVICE AND EXCESSIVE FORCE WAS USED DURING INSERTION. THE DEVICE WAS EXCESSIVELY TORQUED. THE LAUNCHER WAS REMOVED FROM THE PATIENT WITHOUT INTERVENTION AND WAS REPLACED WITH ANOTHER LAUNCHER WHEN IMPLANTING A STENT. NO PATIENT INJURY IS REPORTED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7633266 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K022764. One submission often covers many models, so check the product and lot details in each record.
- Z-0979-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F SR4.0 W/SH LAUN CATHETER LA7SR40SH LA 7F 100CM SR40 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-0969-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F 3DRCC LAUNCHER CATHETER LA73DRC LA 7F 100CM 3DRC Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
- Z-0975-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F SR3.5 W/SH LAUN CATHETER LA7SR35SH LA 7F 100CM SR35 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-0974-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F SR3.5 LAUNCHER CATHETER LA7SR35 LA 7F 100CM SR35 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
- Z-0971-06 · Apr 5, 2006 · TerminatedCATHETER LA7MB1A LA 7F 110CM M CATHETER LA7MB1A LA 7F 110CM MB Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are intr
- Z-0976-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F SR4.0 LAUNCHER CATHETER LA7SR40 LA 7F 100CM SR40 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
- Z-1009-06 · Apr 5, 2006 · TerminatedCATHETER SB73DRCSH SB 7F 100CM Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are introduced into the coronary or peri
- Z-0977-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F SR4.0 W/SH LAUN CATHETER LA7SR40SH LA 7F 100CM SR40 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-0972-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F SR3.0 LAUNCHER CATHETER LA7SR30 LA 7F 100CM SR30 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are i
- Z-0973-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F SR3.0 W/SH LAUN CATHETER LA7SR30SH LA 7F 100CM SR30 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are
- Z-0970-06 · Apr 5, 2006 · TerminatedCATHETER LA7IMAA LA 7F 110CM I CATHETER LA7IMAA LA 7F 110CM IMA Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
- Z-0978-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F SR4.0 LAUNCHER CATHETER LA7SR40 LA 7F 100CM SR40 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
- Z-0980-06 · Apr 5, 2006 · TerminatedCATH. GUIDE 7F SR5.0 LAUNCHER CATHETER LA7SR50 LA 7F 100CM SR50 Coronary Guiding catheter designed to provide a pathway through which therapeutic and/or diagnostic devices are int
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page