Infinity Internal Hex System 203711Recalls & reported problems

Ace Surgical Supply CO., Inc. · infinity INTERNAL 3.7x11.5MM Ø3.5HD HEX IMPLANT 6AL-4V ELI · Class 2 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Quick summary

This ACE Surgical Infinity dental implant is a screw-shaped implant placed in the jawbone to support a replacement tooth. Of the 161 reports, many describe implants that failed to bond with the bone or became loose, and some describe infection or numbness. The reports include no deaths and 161 injuries. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
161
Deaths reported
0
Injuries reported
161
Recalls naming it
0

Summary

The FDA's MAUDE database contains 161 adverse event reports that list this exact device (DI 00614950004645), received between Dec 28, 2015 and Apr 1, 2026 — classified as 161 injuries.

The most frequently reported specific device problem is “Osseointegration Problem” (127 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 2 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 1 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Osseointegration Problem127
  • Failure to Osseointegrate124
  • Insufficient Device Problem Information12
  • Patient Device Interaction Problem7
  • Loss of Osseointegration2
  • Therapeutic or Diagnostic Output Failure2

Patient problems

  • Failure of Implant159
  • Pain38
  • Unspecified Infection12
  • Numbness9
  • Fistula7
  • Swelling4
  • Inadequate Osseointegration1
  • Insufficient Information1

Recent adverse event reports

The 25 most recent of 161 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 1, 2026Failure to Osseointegrate

    FTO - IMPLANT BECAME LOOSE.

    Patient problems: Insufficient Information

    MAUDE report 24758816 ↗
  • InjuryFeb 18, 2025Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT SPINNING WITH SLIGHT INFECTION.

    Patient problems: Failure of Implant

    MAUDE report 21405350 ↗
  • InjuryFeb 20, 2024Loss of Osseointegration; Loss of Osseointegration

    LOSS OF INTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 18743688 ↗
  • InjuryJan 29, 2024Failure to Osseointegrate; Failure to Osseointegrate

    MOBILITY AND SLIGHT INFECTION.

    Patient problems: Failure of Implant

    MAUDE report 18601670 ↗
  • InjuryJan 4, 2024Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT LOSS DUE TO POOR BONE QUALITY AND POOR HYGIENE.

    Patient problems: Failure of Implant

    MAUDE report 18447442 ↗
  • InjuryMay 24, 2023Patient Device Interaction Problem; Patient Device Interaction Problem

    FAILED TO INTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 16995417 ↗
  • InjuryMay 23, 2023Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED TO INTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 16984134 ↗
  • InjuryMay 23, 2023Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED TO INTEGRATE.

    Patient problems: Failure of Implant; Swelling/ Edema

    MAUDE report 16983647 ↗
  • InjuryMay 10, 2023Patient Device Interaction Problem; Patient Device Interaction Problem

    SAME DAY SPINNER.

    Patient problems: Failure of Implant

    MAUDE report 16906744 ↗
  • InjuryMay 10, 2023Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT FAILED TO INTEGRATE.

    Patient problems: Failure of Implant

    MAUDE report 16904990 ↗
  • InjuryApr 27, 2023Patient Device Interaction Problem; Patient Device Interaction Problem

    SAME DAY SPINNER.

    Patient problems: Failure of Implant

    MAUDE report 16827167 ↗
  • InjuryJan 5, 2022Failure to Osseointegrate; Failure to Osseointegrate

    BONE QUALITY.

    Patient problems: Failure of Implant

    MAUDE report 13168609 ↗
  • InjuryDec 22, 2021Failure to Osseointegrate; Therapeutic or Diagnostic Output Failure

    BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS UP TO ONE YEAR AFTER PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY. PAIN WAS REPORTED.

    Patient problems: Failure of Implant; Pain

    MAUDE report 13059862 ↗
  • InjuryDec 22, 2021Failure to Osseointegrate; Failure to Osseointegrate

    BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE IV. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY. MOBILITY WAS REPORTED.

    Patient problems: Failure of Implant

    MAUDE report 13059853 ↗
  • InjuryDec 22, 2021Therapeutic or Diagnostic Output Failure

    BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS UP TO ONE TO FIVE YEARS AFTER PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY. MOBILITY WAS REPORTED.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 13059849 ↗
  • InjuryOct 19, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    PAIN AND SWELLING WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS 1 TO 5 YEARS AFTER PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant; Pain

    MAUDE report 12657218 ↗
  • InjuryOct 4, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY, FISTULA AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant; Fistula

    MAUDE report 12567717 ↗
  • InjurySep 2, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 12417819 ↗
  • InjuryJul 29, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE (ALLOGRAFT) WAS PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 12246482 ↗
  • InjuryJun 21, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY AND IMPLANT FRACTURE WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE (ALLOGRAFT) WAS PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 12035299 ↗
  • InjuryJun 9, 2021Failure to Osseointegrate; Patient Device Interaction Problem; Failure to Osseointegrate; Patient Device Interaction Problem

    SWELLING AND BLEEDING WERE REPORTED. BONE QUALITY WAS IDENTIFIED AS TYPE I. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 11967260 ↗
  • InjuryJun 9, 2021Failure to Osseointegrate; Patient Device Interaction Problem; Failure to Osseointegrate; Patient Device Interaction Problem

    SWELLING AND BLEEDING WERE REPORTED. BONE QUALITY WAS IDENTIFIED AS TYPE I. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 11967242 ↗
  • InjuryMay 28, 2021Patient Device Interaction Problem; Patient Device Interaction Problem

    BONE QUALITY WAS TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS NOT ACHIEVED AT SURGERY. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS PERFORMED AT THE TIME OF SURGERY (ALLOGRAFT).

    Patient problems: Failure of Implant

    MAUDE report 11904165 ↗
  • InjuryApr 22, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    XEROSTOMIA AND MOBILITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 11711824 ↗
  • InjuryApr 22, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY, PAIN, BLEEDING AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant; Pain

    MAUDE report 11711810 ↗