Infinity Internal Hex System 204108Recalls & reported problems

Ace Surgical Supply CO., Inc. · infinity INTERNAL 4.1x8.0MM Ø3.5HD HEX IMPLANT 6AL-4V ELI · Class 2 · Implant

Quick summary

This ACE Surgical infinity internal hex implant is a root-form dental implant placed into bone. Its 152 adverse event reports are all listed as injuries, with no deaths, and most describe implants that failed to fuse with bone or were lost, sometimes linked to poor bone quality. Other reports mention pain, infection and an implant dropping during surgery. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
152
Deaths reported
0
Injuries reported
152
Recalls naming it
0

Summary

The FDA's MAUDE database contains 152 adverse event reports that list this exact device (DI 00614950004683), received between Nov 24, 2015 and Jun 2, 2026 — classified as 152 injuries.

The most frequently reported specific device problem is “Osseointegration Problem” (122 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 2 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 3 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Osseointegration Problem122
  • Failure to Osseointegrate116
  • Insufficient Device Problem Information8
  • Loss of Osseointegration5
  • Device Issue2
  • Appropriate Device Problem Term/Code Not Available1
  • No Apparent Adverse Event1
  • Output Problem1

Patient problems

  • Failure of Implant150
  • Pain40
  • Unspecified Infection19
  • Numbness3
  • Swelling2
  • Fistula1
  • Insufficient Information1
  • Limited Mobility Of The Implanted Joint1

Recent adverse event reports

The 25 most recent of 152 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 2, 2026Failure to Osseointegrate; No Apparent Adverse Event

    IMPLANT DROPPED DURING SURGERY.

    Patient problems: Insufficient Information

    MAUDE report 25360391 ↗
  • InjuryJun 5, 2024Loss of Osseointegration; Loss of Osseointegration

    LOST OSSEOINTEGRATION.

    Patient problems: Failure of Implant

    MAUDE report 19472457 ↗
  • InjuryMay 20, 2024Loss of Osseointegration; Loss of Osseointegration

    IMPLANT LOSS DUE TO POOR BONE QUALITY.

    Patient problems: Failure of Implant

    MAUDE report 19350439 ↗
  • InjuryMay 20, 2024Loss of Osseointegration; Loss of Osseointegration

    IMPLANT LOSS DUE TO POOR BONE QUALITY.

    Patient problems: Failure of Implant

    MAUDE report 19350438 ↗
  • InjuryMay 20, 2024Loss of Osseointegration; Loss of Osseointegration

    IMPLANT LOSS DUE TO POOR BONE QUALITY.

    Patient problems: Failure of Implant

    MAUDE report 19350437 ↗
  • InjuryFeb 29, 2024Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT SLIGHTLY INFECTED AND SPINNING.

    Patient problems: Failure of Implant

    MAUDE report 18812807 ↗
  • InjuryFeb 29, 2024Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT SLIGHTLY INFECTED AND SPINNING.

    Patient problems: Failure of Implant

    MAUDE report 18812803 ↗
  • InjuryJan 5, 2024Failure to Osseointegrate; Failure to Osseointegrate

    IMPLANT LOSS DUE TO POOR BONE QUALITY.

    Patient problems: Failure of Implant

    MAUDE report 18451221 ↗
  • InjuryOct 19, 2023Failure to Osseointegrate; Failure to Osseointegrate

    NO OSSEOINTEGRATION AND SLIGHT INFECTION.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 17969563 ↗
  • InjuryAug 9, 2023Loss of Osseointegration; Loss of Osseointegration

    MOBILITY AFTER 1 YEAR & PATIENT LOST IT DIRECTLY.

    Patient problems: Failure of Implant

    MAUDE report 17494319 ↗
  • InjuryJul 24, 2023Osseointegration Problem; Osseointegration Problem

    INADEQUATE BONE TYPE AND NON-REGULAR HYGEINE.

    Patient problems: Failure of Implant

    MAUDE report 17385095 ↗
  • InjuryApr 27, 2023Failure to Osseointegrate; Failure to Osseointegrate

    SAME DAY SPINNER.

    Patient problems: Failure of Implant

    MAUDE report 16827319 ↗
  • InjuryJan 5, 2022Output Problem

    BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS UP TO ONE YEAR AFTER PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY. MOBILITY AND PROVISIONAL PROSTHESIS WERE REPORTED.

    Patient problems: Failure of Implant

    MAUDE report 13170335 ↗
  • InjuryJan 5, 2022Failure to Osseointegrate; Failure to Osseointegrate

    BONE QUALITY.

    Patient problems: Failure of Implant

    MAUDE report 13170331 ↗
  • InjuryJan 5, 2022Failure to Osseointegrate; Failure to Osseointegrate

    BONE QUALITY.

    Patient problems: Failure of Implant

    MAUDE report 13168618 ↗
  • InjuryOct 5, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE IV. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 12575475 ↗
  • InjuryOct 4, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY, NOT ENOUGH BONE AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE IV. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 12567732 ↗
  • InjuryOct 4, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY, PAIN AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE IV. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant; Pain

    MAUDE report 12567708 ↗
  • InjuryOct 4, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY. PATIENT IS A SMOKER.

    Patient problems: Failure of Implant

    MAUDE report 12567701 ↗
  • InjurySep 2, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE (ALLOGRAFT) WAS PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 12417801 ↗
  • InjuryJul 21, 2021Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    MOBILITY AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 12201842 ↗
  • InjuryJun 10, 2021Failure to Osseointegrate

    INFECTION AND MOBILITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 11975525 ↗
  • InjuryJun 1, 2021Unstable; Failure to Osseointegrate

    BONE QUALITY WAS TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS NOT ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS PERFORMED AT THE TIME OF SURGERY (BONE GRAFT AND 1 COLLAGEN PLUG).

    Patient problems: Failure of Implant

    MAUDE report 11915323 ↗
  • InjuryMay 28, 2021Patient Device Interaction Problem; Patient Device Interaction Problem

    BONE QUALITY WAS TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS NOT ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT TIME OF SURGERY. DR USED WRONG SIZE.

    Patient problems: Failure of Implant

    MAUDE report 11904111 ↗
  • InjuryApr 22, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY, PAIN AND INADEQUATE BONE QUALITY/BONE QUANTITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY. PATIENT IS A SMOKER.

    Patient problems: Failure of Implant; Pain

    MAUDE report 11711800 ↗

Other IMPLANT, ENDOSSEOUS, ROOT-FORM devices

All IMPLANT, ENDOSSEOUS, ROOT-FORM devices →