Infinity External Hex Implant System 403711Recalls & reported problems

Ace Surgical Supply CO., Inc. · INFINITY EXTERNAL 3.75X11.5MM Ø4.0HD HEX IMPLANT TI CP GRADE 4 · Class 2 · Implant

All models of Infinity External Hex Implant System (16)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Quick summary

This ACE Surgical Infinity external hex dental implant is a screw-shaped titanium fixture placed in the jawbone to anchor a tooth replacement. Across 44 reports, all describe injuries with no deaths, and most describe implants that never fused properly with the bone or later lost that fusion, leading to pain, swelling, numbness, infection around the implant, fistula, and a loose or failed implant. The reports run from 2015 to 2024, with none in the past 12 months. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
44
Deaths reported
0
Injuries reported
44
Recalls naming it
0

Summary

The FDA's MAUDE database contains 44 adverse event reports that list this exact device (DI 00614950005420), received between Dec 1, 2015 and Jun 4, 2024 — classified as 44 injuries.

The most frequently reported specific device problem is “Osseointegration Problem” (35 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Osseointegration Problem35
  • Failure to Osseointegrate14
  • Insufficient Device Problem Information7
  • Loss of Osseointegration1

Patient problems

  • Failure of Implant42
  • Pain12
  • Unspecified Infection10
  • Numbness5
  • Swelling5
  • Fistula4
  • Patient Problem/Medical Problem1

Recent adverse event reports

The 25 most recent of 44 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 4, 2024Loss of Osseointegration; Loss of Osseointegration

    PERI IMPLANTITIS.

    Patient problems: Failure of Implant

    MAUDE report 19464140 ↗
  • InjuryMay 24, 2023Osseointegration Problem; Osseointegration Problem

    TIME OF LOSS IN RELATION TO THE IMPLEMENTATION WAS 1 TO 5 YEARS AFTER PROSTHETIC RESTORATION.

    Patient problems: Failure of Implant

    MAUDE report 16992352 ↗
  • InjuryMar 29, 2021Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    INADEQUATE BONE QUALITY/BONE QUANTITY WAS REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE IV. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 11581164 ↗
  • InjuryNov 16, 2020Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    PAIN AND MOBILITY WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE IV. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 10842694 ↗
  • InjuryNov 16, 2020Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY WAS REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 10842693 ↗
  • InjuryJun 27, 2019Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    INADEQUATE BONE QUALITY/BONE QUANTITY, PAIN, SWELLING, BLEEDING, NUMBNESS, MOBILITY AND FISTULA WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant; Fistula; Numbness; Swelling

    MAUDE report 8738607 ↗
  • InjuryMar 19, 2019Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    PAIN WAS REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED.

    Patient problems: Failure of Implant; Pain

    MAUDE report 8431368 ↗
  • InjuryOct 19, 2018Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY, PERI-IMPLANTITIS AND ASYMPTOMATIC WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE IV. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant

    MAUDE report 7983349 ↗
  • InjuryOct 19, 2018Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY, PAIN AND POOR ORAL HYGIENE WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS UP TO 1-5 YEARS AFTER PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY.

    Patient problems: Failure of Implant; Pain

    MAUDE report 7983329 ↗
  • InjuryMay 10, 2018Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY, SWELLING, POOR ORAL HYGIENE AND PAIN WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY. PATIENT IS A SMOKER.

    Patient problems: Failure of Implant; Pain; Swelling

    MAUDE report 7504241 ↗
  • InjuryMay 7, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    INFECTION, ASINTOMATICA, BAD ORAL HYGIENE AND PERI-IMPLANTITIS WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS ACHIEVED. PATIENT IS A SMOKER.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 7490104 ↗
  • InjuryJan 9, 2018Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    MOBILITY WAS REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEONTEGRATION WAS NOT ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY. PATIENT IS A SMOKER.

    Patient problems: Failure of Implant

    MAUDE report 7174653 ↗
  • InjuryDec 21, 2017Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED.

    Patient problems: Failure of Implant

    MAUDE report 7137428 ↗
  • InjuryNov 14, 2017Insufficient Device Problem Information; Insufficient Device Problem Information

    MOBILITY AND PAIN WAS REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE IV. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS ACHIEVED. AUGMENTATION PROCEDURE WAS NOT PERFORMED AT THE TIME OF SURGERY. PATIENT IS A SMOKER.

    Patient problems: Failure of Implant; Pain

    MAUDE report 7027519 ↗
  • InjuryNov 13, 2017Insufficient Device Problem Information; Insufficient Device Problem Information

    MOBILITY WAS REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED.

    Patient problems: Patient Problem/Medical Problem

    MAUDE report 7026000 ↗
  • InjuryNov 13, 2017Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    INFECTION, BLEEDING, SWELLING AND NUMBNESS WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED.

    Patient problems: Failure of Implant; Numbness; Swelling; Unspecified Infection

    MAUDE report 7025989 ↗
  • InjuryNov 13, 2017Insufficient Device Problem Information; Insufficient Device Problem Information

    PAIN, FISTULA AND INFECTION WAS REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS ACHIEVED.

    Patient problems: Failure of Implant; Fistula; Pain; Unspecified Infection

    MAUDE report 7024616 ↗
  • InjuryNov 13, 2017Insufficient Device Problem Information; Insufficient Device Problem Information

    INADEQUATE BONE QUALITY/BONE QUANTITY, MOBILITY, INFECTION, PAIN, BLEEDING, SWELLING, NUMBNESS, PERI-IMPLANTITIS AND FISTULA WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE IV. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS 1 TO 5 YEARS AFTER PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS ACHIEVED. PATIENT IS A SMOKER.

    Patient problems: Failure of Implant; Numbness; Pain; Unspecified Infection

    MAUDE report 7024614 ↗
  • InjurySep 5, 2017Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    BLEEDING, SWELLING, NUMBNESS, FISTULA AND PERI-IMPLANTITIS WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE WAS TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. PATIENT IS A SMOKER AND HAS XEROSTOMIA.

    Patient problems: Failure of Implant; Fistula; Numbness; Swelling

    MAUDE report 6841396 ↗
  • InjurySep 5, 2017Failure to Osseointegrate; Osseointegration Problem; Failure to Osseointegrate; Osseointegration Problem

    BLEEDING, SWELLING, NUMBNESS, FISTULA AND PERI-IMPLANTITIS WERE REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE WAS TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS BEFORE PROSTHETIC RESTORATION. PRIMARY STABILITY WAS ACHIEVED. OSSEOINTEGRATION WAS NOT ACHIEVED. PATIENT IS A SMOKER AND HAS XEROSTOMIA.

    Patient problems: Failure of Implant; Fistula; Numbness; Swelling

    MAUDE report 6841393 ↗
  • InjuryApr 24, 2017Insufficient Device Problem Information; Insufficient Device Problem Information

    BLEEDING AND MOBILITY WAS REPORTED. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS 1-5 YEARS AFTER PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS ACHIEVED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. PATIENT HAS PERI-IMPLANTITIS.

    Patient problems: Failure of Implant

    MAUDE report 6517035 ↗
  • InjuryFeb 23, 2017Insufficient Device Problem Information; Insufficient Device Problem Information

    PAIN WAS REPORTED. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS 1-5 YRS AFTER FINAL PROSTHETIC RESTORATION. PRIMARY STABILITY AND OSSEOINTEGRATION WAS ACHIEVED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE II. IT WAS ALSO REPORTED FRACTURE OF THE IMPLANT.

    Patient problems: Failure of Implant

    MAUDE report 6353367 ↗
  • InjuryDec 29, 2016Osseointegration Problem; Osseointegration Problem

    INFECTION WAS REPORTED. NO OSSEOINTEGRATION 1-3 MONTHS BEFORE RESTORATION.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 6214365 ↗
  • InjuryNov 7, 2016Osseointegration Problem; Osseointegration Problem

    MOBILITY AND INFECTION WAS REPORTED. BONE QUALITY AT THE TIME OF IMPLANT FAILURE TYPE III. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS OVER A YEAR AFTER FINAL PROSTHETIC RESTORATION. IT WAS ALSO REPORTED NO OSSEOINTEGRATION OF THE IMPLANT.

    Patient problems: Failure of Implant; Unspecified Infection

    MAUDE report 6083432 ↗
  • InjuryNov 7, 2016Osseointegration Problem; Osseointegration Problem

    PAIN WAS REPORTED. TIME OF LOSS IN RELATION TO THE IMPLANTATION WAS MORE THAN A YEAR AFTER PROSTHETIC RESTORATION. IT WAS ALSO REPORTED BREAKAGE OF THE IMPLANT.

    Patient problems: Failure of Implant; Pain

    MAUDE report 6083387 ↗