MEDRAD® Mark 7 Arterion Injection System (REF ART 700 PEDL, ART 700 TABL, ART 700 OCS, ART 700 BASC, ART 700 VFL)Recalls & reported problems

Bayer Medical Care Inc. · "MARK 7 ARTERION, PACKAGED, BASE SYSTEM (60726793)" · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00616258009360), received between May 7, 2020 and Mar 12, 2025 — classified as 2 injuries.

1 other recall cover devices cleared under the same FDA submission (K112086); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2

Patient problems

  • Air Embolism2
  • Low Oxygen Saturation1
  • Stroke/CVA1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryMar 12, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    BAYER MEDICAL CARE INC. WAS INFORMED THAT 65-YEAR-OLD MALE HAD EXPERIENCED LEFT-SIDED WEAKNESS AND A DROP IN OXYGEN SATURATION LEVELS DURING A LEFT HEART CATHETERIZATION WHILE CONNECTED TO A MEDRAD® MARK 7 ARTERION INJECTION SYSTEM (SN (B)(6)). MEDICAL STAFF SUSPECTED AN ALLEGED AIR INJECTION OCCURRED WHILE THE INJECTOR WAS CONNECTED TO THE PATIENT; HOWEVER, THIS WAS NOT CONFIRMED ON THE FLUOROSCOPIC IMAGES FROM THE PROCEDURE. FOLLOWING THE DEVELOPMENT OF THE REPORTED SYMPTOMS, A STROKE CODE WAS CALLED, THE PATIENT WAS GIVEN MEDICATION, A TEMPORARY PACEMAKER, AND WAS TAKEN TO THE RADIOLOGY DEPARTMENT WHERE A CT OF THE HEAD WAS PERFORMED, AND AIR WAS VISUALIZED ON THE DISPLAYED IMAGES. THE AMOUNT OF AIR WAS NOT QUANTIFIED. THE PATIENT IS IN THE ICU AND IS REPORTED AS BEING STABLE.

    Patient problems: Air Embolism; Low Oxygen Saturation; Stroke/CVA

    MAUDE report 21584442 ↗
  • InjuryMay 7, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE SITE REPORTED THE FOLLOWING: A PATIENT WAS UNDERGOING A TAVR PROCEDURE AND SUFFERED AN AIR INJECTION WHILE CONNECTED TO THE ARTERION INJECTOR SYSTEM. THE AMOUNT OF AIR IS UNKNOWN. THE PATIENT WAS REPORTED TO EXPERIENCE CHANGES TO THEIR EKG, BLOOD PRESSURE, AND OXYGEN SATURATION. NO FURTHER DETAILS HAVE BEEN PROVIDED BY THE CUSTOMER SITE FOLLOWING MULTIPLE ATTEMPTS TO OBTAIN ADDITIONAL INFORMATION.

    Patient problems: Air Embolism

    MAUDE report 10032471 ↗

FDA clearance and classification

Cleared through Special 510(k) K112086 on Oct 14, 2011 (decision: Substantially Equivalent). Submitted by Medrad, Inc. as “Medrad Mark 7 Arterion (Pedestal System / Table Mount System), Medrad Mark 7 Arterion Syringe”. The FDA review took 85 days. FDA record ↗

The FDA regulates product code DXT (injector and syringe, angiographic) under 21 CFR 870.1650 as a Class II device. 21 CFR 870.1650 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K112086. One submission often covers many models, so check the product and lot details in each record.

  • Z-0745-2019 · Dec 14, 2018 · Terminated
    MAVIG Portegra or Portegra2 Overhead Counterpoise System (OCS) used in conjunction with the Medrad Stellant CT Injection System (Certegra Workstation), Medrad Mark 7 Arterion" Inje

Common questions about the MEDRAD® Mark 7 Arterion Injection System

Has the MEDRAD® Mark 7 Arterion Injection System been recalled?

No FDA recall record in our data names this exact device identifier (DI 00616258009360), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the MEDRAD® Mark 7 Arterion Injection System?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between May 7, 2020 and Mar 12, 2025. In those reports, the most common patient problems are “Air Embolism” (2), “Low Oxygen Saturation” (1) and “Stroke/CVA” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the MEDRAD® Mark 7 Arterion Injection System?

None of the reports are classified as deaths, 2 as injuries and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the MEDRAD® Mark 7 Arterion Injection System FDA approved?

It was cleared through Special 510(k) K112086 on Oct 14, 2011. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the MEDRAD® Mark 7 Arterion Injection System, and is it still sold?

The FDA's device database lists Bayer Medical Care Inc. as the company responsible for it (brand MEDRAD® Mark 7 Arterion Injection System, model Arterion). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Injector And Syringe, Angiographic devices

All Injector And Syringe, Angiographic devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page