Skip to content

Air-Charged Single Sensor Coudé Catheter CAT878Recalls & reported problems

Laborie Medical Technologies Canada ULC · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00627825001045), received between Mar 17, 2019 and Jun 13, 2019 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Material Protrusion/Extrusion” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Material Protrusion/Extrusion2

Patient problems

  • No Code Available1
  • Tissue Damage1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 13, 2019Material Protrusion/Extrusion

    A LABORIE URETHRAL CATHETER WAS USED IN A PATIENT IN FRANCE AS PART OF A URODYNAMICS STUDY. A METAL FILAMENT IN THE CATHETER WAS PROTRUDING AND RESULTED IN A LESION OF THE PATIENT'S URETHRA.

    Patient problems: No Code Available

    MAUDE report 8695411 ↗
  • MalfunctionMar 17, 2019Material Protrusion/Extrusion

    A LABORIE CATHETER WHICH WAS USED IN A MALE PATIENT IN (B)(6) AS PART OF A URODYNAMICS STUDY HAD A STEEL WIRE PROTRUDING FROM THE CATHETER. THE PHYSICIAN EITHER DID NOT NOTICE THE DEFECT PRIOR TO INSERTING THE CATHETER INTO THE PATIENT, OR THE DEFECT OCCURRED AFTER INSERTION INTO THE PATIENT - WE ARE UNABLE TO TELL BASED ON THE INFORMATION PROVIDED - WHICH RESULTED IN THE PATIENT'S URETHRA RECEIVING MINOR SCRATCHES UPON REMOVAL OF THE CATHETER. NO MEDICAL INTERVENTION WAS REQUIRED AS A RESULT OF THIS PRODUCT MALFUNCTION; THE PATIENT WAS RELEASED AND DID NOT REQUIRE ADDITIONAL FOLLOW-UP OR TREATMENTS.

    Patient problems: Tissue Damage

    MAUDE report 8427288 ↗

FDA clearance and classification

The FDA regulates product code FEN (device, cystometric, hydraulic) under 21 CFR 876.1620 as a Class II device. 21 CFR 876.1620 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Air-Charged Single Sensor Coudé Catheter CAT878

Has the Air-Charged Single Sensor Coudé Catheter CAT878 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00627825001045), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Air-Charged Single Sensor Coudé Catheter CAT878?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between Mar 17, 2019 and Jun 13, 2019. In those reports, the most common specific device problem is “Material Protrusion/Extrusion” (2); the most common patient problem is “Tissue Damage” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Air-Charged Single Sensor Coudé Catheter CAT878?

None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Air-Charged Single Sensor Coudé Catheter CAT878 FDA approved?

Devices of this type (product code FEN) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Laborie Medical Technologies Canada ULC.

Who makes the Air-Charged Single Sensor Coudé Catheter CAT878, and is it still sold?