ADVIA® Chemistry IGM_2 Reagents 10309032Recalls & reported problems
Siemens Healthcare Diagnostics Inc. · IgM - ADVIA Chem. - RGT - 4x90 tests · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00630414513126), received between Jul 20, 2017 and Sep 1, 2017 — classified as 2 malfunctions.
1 other recall cover devices cleared under the same FDA submission (K992662); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 1, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
ON (B)(6) 2017, A DISCORDANT, FALSELY LOW IMMUNOGLOBULIN M_2 (IGM_2) RESULT WAS OBTAINED ON ONE PATIENT SAMPLE WHEN RUN NEAT ON AN ADVIA 2400 INSTRUMENT, WHILE USING REAGENT LOT 411515. ON (B)(6) 2017, THE SAMPLE WAS ANALYZED USING AN ALTERNATE METHODOLOGY, RESULTING HIGH AND INDICATIVE OF HIGH PARAPROTEIN BAND. THE CUSTOMER CONFIRMED THE HIGH RESULT BY REPEATING THE SAMPLE ON THE ALTERNATE METHODOLOGY. THIS PROMPTED THE CUSTOMER TO REPEAT THE SAMPLE AS NEAT AND WITH DILUTION ON THE ADVIA 2400 INSTRUMENT. THIS IS WHEN THE CUSTOMER DETERMINED THAT THE NEAT RESULTS AND A RESULT OBTAINED UPON INITIAL DILUTION ON THE ADVIA 2400 INSTRUMENT WERE DISCORDANT. THE RESULTS FROM THE ELECTROPHORESIS AND THE RESULTS OBTAINED ON THE ADVIA 2400 INSTRUMENT UPON MANUAL DILUTION WERE CONSIDERED CORRECT. THE DISCORDANT RESULT WAS REPORTED TO THE PHYSICIAN(S), WHO QUESTIONED IT. THE CORRECTED RESULTS WERE REPORTED TO THE PHYSICIAN(S). THERE ARE NO REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCE DUE TO THE DISCORDANT, FALSELY LOW IGM_2 RESULTS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6838417 ↗MalfunctionJul 20, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DISCORDANT, FALSELY LOW IMMUNOGLOBULIN M_2 (IGM_2) RESULTS WERE OBTAINED ON ONE PATIENT SAMPLE WHEN RUN NEAT ON AN ADVIA 2400 INSTRUMENT, WHILE USING REAGENT LOT 411515. THE SAMPLE WAS MANUALLY DILUTED WITH 1:10 DILUTION FACTOR AND REPEATED TWICE IN DUPLICATE ON THE SAME INSTRUMENT, RESULTING HIGHER EACH TIME. THE DISCORDANT RESULTS WERE REPORTED TO THE PHYSICIAN(S), WHO QUESTIONED THEM. THE CORRECTED RESULTS WERE REPORTED TO THE PHYSICIAN(S). THERE ARE NO REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCE DUE TO THE DISCORDANT, FALSELY LOW IGM_2 RESULTS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6727816 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K992662. One submission often covers many models, so check the product and lot details in each record.
- Z-1003-2024 · Dec 15, 2023 · Open, ClassifiedTotal immunoglobulin M (IgM total) IVD, kit, nephelometry/turbidimetry
Other METHOD, NEPHELOMETRIC, IMMUNOGLOBULINS (G, A, M) devices
- AU OSR61173Beckman Coulter, Inc. · Method, Nephelometric, Immunoglobulins (G, A, M)1 recall0 reports
- IMMAGE 447610Beckman Coulter, Inc. · Method, Nephelometric, Immunoglobulins (G, A, M)1 recall0 reports
- Atellica CH IgM_2 11097620Siemens Healthcare Diagnostics Inc. · METHOD, NEPHELOMETRIC, IMMUNOGLOBULINS (G, A, M)1 recall0 reports
- AU OSR61171Beckman Coulter, Inc. · Method, Nephelometric, Immunoglobulins (G, A, M)1 recall0 reports
- VITROS 6801732Ortho-Clinical Diagnostics, Inc. · METHOD, NEPHELOMETRIC, IMMUNOGLOBULINS (G, A, M)1 report
- Immunoglobulin M 20737771322Roche Diagnostics GmbH · METHOD, NEPHELOMETRIC, IMMUNOGLOBULINS (G, A, M)1 report
- N Antisera to Human IgM 10446303Siemens Healthcare Diagnostics Products GmbH · METHOD, NEPHELOMETRIC, IMMUNOGLOBULINS (G, A, M)1 report
- DImension Vista® Immunoglobulin M Flex® reagent cartridge 10445904Siemens Healthcare Diagnostics Products GmbH · METHOD, NEPHELOMETRIC, IMMUNOGLOBULINS (G, A, M)1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page