ADVIA Centaur® TSH3-UL 10282378Recalls & reported problems
Siemens Healthcare Diagnostics Inc. · TSH - CENTAUR - RGT - 100 tests · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00630414535647), received between Aug 4, 2017 and Aug 31, 2017 — classified as 2 malfunctions.
4 other recalls cover devices cleared under the same FDA submission (K083844); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 31, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A FALSE LOW ADVIA CENTAUR XP TSH3-ULTRA ((TSH3-UL) RESULT WAS OBTAINED BY THE CUSTOMER, AND THE RESULT WAS QUESTIONED BY THE CLINICIAN. THE PATIENT SAMPLE WAS TESTED FOR TSH ON THE ADVIA CENTAUR XP, AND THE RESULT WAS NORMAL. THE PATIENT SAMPLE WAS SENT TO ANOTHER LABORATORY, TESTED FOR TSH ON AN ALTERNATE TEST METHOD (SIEMENS IMMULITE), AND THE RESULT WAS NORMAL. THE PATIENT SAMPLE WAS REPEATED AT THE ORIGINAL LABORATORY ON A SECOND ALTERNATE TSH TEST METHOD, AND THE RESULT WAS NORMAL. THE CUSTOMER PERFORMED REPEAT TSH3-UL TESTING OF THE PATIENT SAMPLE AND THE RESULT WAS LOW. THE ALTERNATE TSH TEST METHOD RESULTS WERE REPORTED TO THE PHYSICIAN. THERE WAS NO REPORT OF PATIENT TREATMENT BEING PRESCRIBED OR ALTERED, OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT ADVIA CENTAUR XP TSH3-ULTRA RESULT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6835646 ↗MalfunctionAug 4, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
A FALSE LOW ADVIA CENTAUR TSH3-ULTRA ((TSH3-UL) RESULT WAS OBTAINED ON A PATIENT SAMPLE. THE PHYSICIAN WAS EXPECTING A HIGHER TSH VALUE, AND QUESTIONED THE RESULT. THE PATIENT SAMPLE WAS SENT TO ANOTHER LABORATORY, TESTED ON AN ALTERNATE TSH TEST METHOD, AND THE RESULT WAS HIGHER. THE PHYSICIAN SUSPECTS A POTENTIAL SAMPLE INTERFERENT. THERE WAS NO REPORT OF PATIENT TREATMENT BEING PRESCRIBED OR ALTERED, OR ADVERSE HEALTH CONSEQUENCES DUE TO THE DISCORDANT ADVIA CENTAUR XP TSH3-ULTRA RESULT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6768131 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K083844. One submission often covers many models, so check the product and lot details in each record.
- Z-1654-2014 · Apr 10, 2014 · TerminatedADVIA Centaur Systems TSH3 Ultra , Ready Pack, 500 test Catalog Number: 06491080; Siemens Material Number: 10282379. Intended for the invitro diagnostic use in quantitative determ
- Z-1653-2014 · Apr 10, 2014 · TerminatedADVIA Centaur Systems TSH3 Ultra Ready Pack, 100 test Catalog Number: 06491072; Siemens Material Number: 10282378. Intended for the invitro diagnostic use in quantitative determi
- Z-1881-2013 · May 10, 2013 · TerminatedADVIA Centaur Systems TSH3 Ultra ReadyPack ((REF 06491072 - 100 Tests, REF 06491080 - 500 Tests, REF 04862625 - 2500T). Intended to quantitatively measure human thyroid stimulatin
- Z-2313-2012 · Jul 25, 2012 · TerminatedSiemens ADVIA Centaur Multi-Diluent 1 - Used for automated dilutions for the ADVIA Centaur BNP and TSH3 Ultra assays when on-board the ADVIA Centaur or ADVIA Centaur XP systems. Ca
Other RADIOIMMUNOASSAY, THYROID-STIMULATING HORMONE devices
- VITROS 1912997Ortho Clinical Diagnostics · RADIOIMMUNOASSAY, THYROID-STIMULATING HORMONE201 reports
- Alinity 07P4830Abbott Ireland · RADIOIMMUNOASSAY, THYROID-STIMULATING HORMONE2 recalls91 reports
- Elecsys TSH 08443432190Roche Diagnostics GmbH · RADIOIMMUNOASSAY, THYROID-STIMULATING HORMONE116 reports
- ARCHITECT 7K62-30Abbott Ireland · RADIOIMMUNOASSAY, THYROID-STIMULATING HORMONE58 reports
- Elecsys TSH Assay 11731459122Roche Diagnostics GmbH · RADIOIMMUNOASSAY, THYROID-STIMULATING HORMONE55 reports
- Access TSH (3rd IS) C28643Beckman Coulter, Inc. · Radioimmunoassay, Thyroid-Stimulating Hormone1 recall0 reports
- Alinity 07P4820Abbott Ireland · RADIOIMMUNOASSAY, THYROID-STIMULATING HORMONE44 reports
- ARCHITECT 7K62-35Abbott Ireland · RADIOIMMUNOASSAY, THYROID-STIMULATING HORMONE25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.