Skip to content

Atellica CH ECre_2 11097533Recalls & reported problems

Siemens Healthcare Diagnostics Inc. · Enzymatic Creatinine ( Ecrea_2) Atellica CH - RGT 1400T · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00630414595795), received between Dec 23, 2019 and Sep 3, 2024 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Low Test Results” (6 reports).

1 FDA recall record name this device's identifier.

4 other recalls cover devices cleared under the same FDA submission (K070727); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Dec 18, 2019Class IITerminated

    There is a potential for falsely depressed creatinine results for patients on phenindione therapy when using the enzymatic methodology. Interference has not been observed with the creatinine Jaffe methodology.

    Z-1231-2020 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported problems

Device problems

  • Low Test Results6

Patient problems

  • No Clinical Signs, Symptoms or Conditions5
  • No Patient Involvement1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 3, 2024Low Test Results; Low Test Results

    THE CUSTOMER REPORTED AN ERRONEOUS DEPRESSED ENZYMATIC CREATININE_2 (ECRE_2) PATIENT SAMPLE RESULT OBTAINED ON AN ATELLICA CH 930 INSTRUMENT. THE ERRONEOUS RESULT WAS NOT REPORTED TO THE PHYSICIAN. THE SAMPLE WAS REPROCESSED ON THE INITIAL ATELLICA CH 930 INSTRUMENT. THE REPROCESSED HIGHER RESULT OBTAINED WAS REPORTED, AS THE CORRECT RESULT, TO THE PHYSICIAN. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE ERRONEOUS DEPRESSED ENZYMATIC CREATININE_2 (ECRE_2) RESULT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20129690 ↗
  • MalfunctionFeb 8, 2024Low Test Results; Low Test Results

    A DISCORDANT FALSELY DEPRESSED ENZYMATIC CREATININE_2 (ECRE_2) PATIENT SAMPLE RESULT WAS OBTAINED ON AN ATELLICA ® CH 930 ANALYZER. THE FALSELY DEPRESSED PATIENT RESULT WAS REPORTED TO THE PHYSICIAN AND WAS QUESTIONED. THE SAME SAMPLE WAS REPROCESSED ON THE SAME ATELLICA ® CH 930 ANALYZER. THE HIGHER REPROCESSED RESULT OBTAINED WAS CONSIDERED CORRECT AND REPORTED TO THE PHYSICIAN. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE FALSELY DEPRESSED ENZYMATIC CREATININE_2 (ECRE_2) PATIENT RESULT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18669272 ↗
  • MalfunctionApr 27, 2023Low Test Results; Low Test Results

    THE CUSTOMER OBSERVED A FALSELY DEPRESSED ENZYMATIC CREATININE_2 (ECRE_2) RESULT ON A MALE PATIENT SAMPLE ON AN ATELLICA CH 930 ANALYZER. THE DISCORDANT RESULT WAS REPORTED TO THE PHYSICIAN(S). IT IS UNKNOWN IF THE PHYSICIAN QUESTIONED THE RESULT. THE SAMPLE WAS REPEATED ON AN ALTERNATE ATELLICA CH 930 ANALYZER AND THE RESULT WAS HIGHER THAN THE ERRONEOUS RESULT. THIS REPEAT RESULT WAS CONSIDERED AS CORRECT BY THE PHYSICIAN(S). A DIFFERENT SAMPLE FROM THE SAME PATIENT WAS REPEATED ON ATELLICA CH 930 ANALYZER WHICH ALSO GAVE A HIGHER RESULT COMPARED TO THE INTIAL RESULT. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE FALSELY DEPRESSED ECRE_2 RESULT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16823163 ↗
  • MalfunctionApr 19, 2023Low Test Results; Low Test Results

    THE CUSTOMER OBSERVED A FALSELY DEPRESSED ENZYMATIC CREATININE_2 (ECRE_2) RESULT ON A FEMALE PATIENT SAMPLE ON AN ATELLICA CH 930 ANALYZER. THE DISCORDANT RESULT WAS REPORTED TO THE PHYSICIAN(S), WHO QUESTIONED THE RESULT. THE SAMPLE WAS REPEATED ON ALTERNATE ATELLICA CH 930 ANALYZERS. THE REPEAT RESULTS WERE HIGHER THAN THE DISCORDANT RESULT. THE REPEAT RESULTS WERE CONSIDERED AS THE CORRECT RESULTS BY THE PHYSICIAN(S). THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE FALSELY DEPRESSED ECRE_2 RESULT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16769960 ↗
  • MalfunctionSep 30, 2020Low Test Results; Low Test Results

    SIEMENS INVESTIGATED THE IMPACT OF THE DRUG ETAMSYLATE ON THE ATELLICA CH ENZYMATIC CREATININE 2 (ECRE 2) ASSAY. SIEMENS PROCESSED SAMPLES AT VARYING CONCENTRATIONS (1.50 MG/DL, 3.00 MG/DL, 4.50 MG/DL, AND 6.00 MG/DL) OF ETAMSYLATE FOR ECRE 2 AND COMPARED THESE RESULTS WITH THE RESULTS OBTAINED A SAMPLE WITH NO ETAMSYLATE. SIEMENS OBSERVED THAT THE BIAS WAS GREATEST FOR THE SAMPLE WITH THE ETAMSYLATE CONCENTRATION OF 6.00 MG/DL. THERE ARE NO KNOWN REPORTS OF PATIENT INTERVENTION OR ADVERSE HEALTH CONSEQUENCES DUE TO THE NEGATIVE BIAS OBSERVED IN ECRE 2 RESULTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 10606551 ↗
  • MalfunctionDec 23, 2019Low Test Results; Low Test Results

    SIEMENS HEALTHCARE DIAGNOSTICS HAS BECOME AWARE OF THE POTENTIAL OF FALSELY DEPRESSED CREATININE RESULTS FOR PATIENTS UNDERGOING PHENINDIONE THERAPY WHEN USING THE ENZYMATIC METHODOLOGY. ADVIA ECRE_2 RESULTS ON A PATIENTS' SAMPLES SHOWED INTERFERENCE WITH THE PHENINDIONE DRUG AND/OR ITS METABOLITES. THE ATELLICA CH ECRE_2 ASSAY USES THE SAME REAGENTS, CALIBRATORS, AND ASSAY CONDITION AS ADVIA ECRE_2, AND IS EXPECTED TO SHOW A SIMILAR NEGATIVE INTERFERENCE IN SAMPLES FROM PATIENTS ON PHENINDIONE THERAPY. PHENINDIONE IS NOT LISTED AS AN INTERFERING SUBSTANCE IN THE ATELLICA CH ENZYMATIC CREATININE_2 (ECRE_2) INSTRUCTIONS FOR USE (IFU).

    Patient problems: No Patient Involvement

    MAUDE report 9512754 ↗

FDA clearance and classification

Cleared through 510(k) K070727 on Aug 3, 2007 (decision: Substantially Equivalent). Submitted by Siemens Medical Solutions Diagnostics as “Advia Chemistry Enzymatic Creatinine_2”. The FDA review took 141 days. FDA record ↗

The FDA regulates product code JFY (enzymatic method, creatinine) under 21 CFR 862.1225 as a Class II device. 21 CFR 862.1225 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K070727. One submission often covers many models, so check the product and lot details in each record.

  • Z-2282-2020 · May 4, 2020 · Terminated
    ADVIA Chemistry Enzymatic Creatinine_2, Siemens Material Number 10335869, UDI Number 00630414526690 - Product Usage: use in the quantitative determination of creatinine in human se
  • Z-2283-2020 · May 4, 2020 · Terminated
    Atellica CH Enzymatic Creatinine_2, Siemens Material Number 11097533, UDI Number 00630414595795 - Product Usage: use in the quantitative determination of creatinine in human serum,
  • Z-1230-2020 · Dec 18, 2019 · Terminated
    ADVIA Chemistry Enzymatic Creatinine (ECRE_2) reagent, SMN 10335869
  • Z-1654-2016 · Mar 17, 2016 · Terminated
    ADVIA CHEMISTRY ENZYMATIC CREATININE_2

Common questions about the Atellica CH ECre_2 11097533

Has the Atellica CH ECre_2 11097533 been recalled?

Yes. 1 FDA recall record names this device's identifier, and the FDA has closed (terminated) it. The recall, Z-1231-2020 (Class II), began on Dec 18, 2019: There is a potential for falsely depressed creatinine results for patients on phenindione therapy when using the enzymatic methodology. Interference has not been observed with the creatinine Jaffe methodology. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

What problems have been reported with the Atellica CH ECre_2 11097533?

The FDA's MAUDE database lists 6 adverse event reports for this device, received between Dec 23, 2019 and Sep 3, 2024. In those reports, the most common specific device problem is “Low Test Results” (6). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Atellica CH ECre_2 11097533?

None of the reports are classified as deaths, 0 as injuries and 6 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Atellica CH ECre_2 11097533 FDA approved?

It was cleared through 510(k) K070727 on Aug 3, 2007. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Atellica CH ECre_2 11097533, and is it still sold?

The FDA's device database lists Siemens Healthcare Diagnostics Inc. as the company responsible for it (brand Atellica CH ECre_2, model 11097533). Its record shows it as no longer in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other ENZYMATIC METHOD, CREATININE devices

All ENZYMATIC METHOD, CREATININE devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page