N/A 945EEX901Recalls & reported problems
Medtronic Sofamor Danek, Inc. · EXTENDER 945EEX901 STIMULATOR · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00643169071865), received between Nov 12, 2018 and Apr 24, 2026 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Use of Device Problem” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Use of Device Problem3
- Device Sensing Problem2
- Break1
- Intermittent Continuity1
- Noise, Audible1
- Unable to Obtain Readings1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Insufficient Information1
- No Consequences Or Impact To Patient1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 24, 2026Device Sensing Problem
IT WAS REPORTED THAT INTRA-OP, LEFT PORT IN ROW 1 STOPPED WORKING AND PROGRAMMING WAS CHANGED TO ROW 2 AND WORKED FOR SEVERAL MINUTES THEN ALL PORTS STOPPED WORKING. A SECOND STIM BOX WAS REPLACED AND ONLY ABOUT 10 MIN OF THE SURGERY WERE SSEPS NOT MONITORED. THERE WAS NO PATIENT IMPACT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24975655 ↗MalfunctionNov 17, 2025Use of Device Problem; Use of Device Problem
IT WAS REPORTED THAT THE DEVICE FAILED THE SELF STIM AND THE RIGHT PORT WAS DAMAGED. THERE WAS NO KNOWN PATIENT IMPACT.
Patient problems: Insufficient Information
MAUDE report 23566207 ↗MalfunctionFeb 25, 2025Unable to Obtain Readings; Unable to Obtain Readings
IT WAS REPORTED THAT PRIOR TO USE, IT WAS FOUND THAT THERE WAS NO SIGNAL AND 2 R BAD. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21455703 ↗MalfunctionJul 29, 2022Use of Device Problem; Use of Device Problem
IT IS REPORTED THAT DEVICE EXPERIENCING COMPLETE FAILURE. THERE IS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15136227 ↗MalfunctionSep 12, 2019Break; Intermittent Continuity; Device Sensing Problem; Noise, Audible; Break; Intermittent Continuity; Device Sensing Problem; Noise, Audible
A HEALTH CARE PROVIDER REPORTED THAT THE DEVICE GET INTERMITTENT MILD NOISE AGAIN AND THE MEP (MOTOR EVOKED POTENTIALS) FUNCTION DOES NOT SEEM TO WORK ALL THE TIME. SWITCHED PORT FOR MEP FROM THE LEFT TO RIGHT BUT HAVEN'T MONITORED ENOUGH CASES NEEDING MOTORS TO DETERMINE IF THAT IS REALLY THE PROBLEM. AT THE START OF CASES, ABLE TO ELICIT MEPS BUT AT THE END NOTHING WAS RECORDED. NOW, THE HCP WAS HEARING SOMETHING INSIDE THE BOX RATTLING; SOMETHING WAS BROKEN. THE PROBLEM HAS OCCURRED INTERMITTENTLY. THERE WAS NO IMPACT ON PATIENT OR SURGEON. ADDITIONAL INFORMATION RECEIVED STATED THAT THE PORT WAS CHANGED.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9005697 ↗MalfunctionNov 12, 2018Use of Device Problem; Use of Device Problem
A HEALTH CARE PROFESSIONAL (HCP) REPORTED THAT THE AMPLIFIER AND STIMULATORS WERE NOT WORKING. THERE WAS NO KNOWN PATIENT IMPACT REPORTED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8061505 ↗
Other STIMULATOR, ELECTRICAL, EVOKED RESPONSE devices
- NIM Vital™ NIM4CM01Medtronic Xomed, Inc. · STIMULATOR, ELECTRICAL, EVOKED RESPONSE3 recalls795 reports
- NIM Vital™ NIM4CPB1Medtronic Xomed, Inc. · STIMULATOR, ELECTRICAL, EVOKED RESPONSE3 recalls331 reports
- NIM Vital NIM4CPB1Medtronic Xomed, Inc. · Stimulator, electrical, evoked response2 recalls208 reports
- POWEREASE™ Instruments 2300000Medtronic Sofamor Danek, Inc. · STIMULATOR, ELECTRICAL, EVOKED RESPONSE1 recall203 reports
- NIM Vital™ NIM4CM01Medtronic Xomed, Inc. · STIMULATOR, ELECTRICAL, EVOKED RESPONSE3 recalls47 reports
- NIM-Response® 8253200Medtronic Xomed, Inc. · STIMULATOR, ELECTRICAL, EVOKED RESPONSE113 reports
- NA DAQ916Medtronic Xomed, Inc. · STIMULATOR, ELECTRICAL, EVOKED RESPONSE80 reports
- Neuromaster G1 DC-200BNihon Kohden Corporation · STIMULATOR, ELECTRICAL, EVOKED RESPONSE73 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page