CAPSTONE CONTROL™ Spinal System 4011022Recalls & reported problems
Medtronic Sofamor Danek, Inc. · SPACER 4011022 12 DEG 10X22 · Class 2 · Implant
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00643169109056), received between Jan 13, 2017 and Jan 19, 2025 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break2
- Migration or Expulsion of Device1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Code Available1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 19, 2025Break; Break
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY FOR SPINAL STENOSIS. IT WAS REPORTED THAT, THE CAGE WAS BROKEN. THE PROCEDURE OR TECHNIQUE PERFORMED WAS TRANSFORAMINAL LUMBAR INTERBODY FUSION. THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS REPORTED AND NO ADDITIONAL TREATMENT OR SURGERY PERFORMED. THERE WERE NO BROKEN FRAGMENTS OF IMPLANT REMAINS IN PATIENT BODY. THERE WAS NO DELAY IN PROCEDURE REPORTED AS A RESULT AND THE REPORTED PRODUCT WAS LOST AFTER SENDING IT FOR WASH. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21187830 ↗MalfunctionFeb 15, 2018Break; Break
IT WAS REPORTED THAT THE PATIENT WAS PRE-OPERATIVELY DIAGNOSED WITH FAILURE OF BONE FUSION OCCURRED DUE TO LOOSENING OF THE POSTERIOR SCREW AND UNDERWENT OBLIQUE LUMBAR INTERBODY FUSION (OLIF) AT L3,L4,L5. DURING SURGERY, WHEN REMOVING THE CAGE BY PERFORMING OLIF, THE MARKER OF CAGE WAS BROKEN. FRAGMENTS OF THE BROKEN PART REMAINED INSIDE THE PATIENT. NO PATIENT COMPLICATIONS WERE REPORTED AS THE RESULT OF THE EVENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7272521 ↗InjuryJan 13, 2017Migration or Expulsion of Device; Migration or Expulsion of Device
IT WAS REPORTED THAT PATIENT WITH DEGENERATIVE SCOLIOSIS UNDERWENT UNDERWENT OBLIQUE LUMBAR INTERBODY FUSION SURGERY AT L2/3/4/5 ON (B)(6) 2016 AND POSTERIOR LUMBAR INTERBODY FUSION AT L5/6 AND L6/S AS TWO-STAGE SURGERY ON (B)(6) 2016. ON AN UNKNOWN DATE, POST-OP, THE CAGE INSERTED AT L6/S IN PLIF SURGERY BACKED OUT. LOWER LIMB SYMPTOM WAS OBSERVED AS CAGE BACKED OUT AT L6/S. PATIENT UNDERWENT REVISION SURGERY ON (B)(6) 2016 IN WHICH SPACER WAS EXPLANTED AND DISCARDED AND NERVE SYMPTOM WAS RESOLVED.
Patient problems: No Code Available
MAUDE report 6248753 ↗
Other Intervertebral fusion device with bone graft, lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.