Attain Command™ + SureValve™ 6250V-45S (UDI 00643169143265)Recalls & reported problems
Medtronic, Inc. · Catheter 6250V-45S Attain Command · Class 2
All models of Attain Command + SureValve (17)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169143265), received between Jan 15, 2020 and Jan 15, 2020 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Cardiac Perforation1
- Pericardial Effusion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 15, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ONE HOUR POST IMPLANT AND ATRIOVENTRICULAR NODE ABLATION RESULTING IN AN UNDERLYING JUNCTIONAL RHYTHM, THE PATIENT EXPERIENCED RUNS OF VENTRICULAR TACHYCARDIA (VT) AND A SUSTAINED TORSADE'S EPISODE. THE RIGHT VENTRICULAR (RV) LEAD EXHIBITED RISING THRESHOLDS. THE NEXT MORNING THE RV LEAD DISPLAYED UNDERSENSING, WITH HIGH AND UNSTABLE THRESHOLDS AND A MICRO-DISLODGEMENT. AN RV LEAD REVISION WAS PLANNED. IT WAS FURTHER REPORTED THAT THE LEFT VENTRICULAR (LV) LEAD WAS NO LONGER FUNCTIONING AND HAD DISLODGED INTO THE RV. THE RV WAS REVISED TO A NEW LOCATION, REMAINS IN USE, AND HAD MEASUREMENTS ALL WITHIN NORMAL RANGES. THE LV LEAD WAS REMOVED AND WHEN THE PHYSICIAN ATTEMPTED TO REGAIN ACCESS TO THE CORONARY SINUS, THE DELIVERY CATHETER PERFORATED AND "MADE ITS OWN TRACK." AN ECHOCARDIOGRAM WAS PERFORMED AN NOTED A SMALL PERICARDIAL EFFUSION. THE LV LEAD REPLACEMENT WAS ABANDONED AND THE DEVICE WAS DOWNGRADED. THE PATIENT WAS ADMINISTERED ALBUMIN AND NO FURTHER INTERVENTION WAS NEEDED. NO FURTHER PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Cardiac Perforation; Pericardial Effusion
MAUDE report 9593726 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page