Skip to content

CAPSTONE PTC™ Spinal System 3992612Recalls & reported problems

Medtronic Sofamor Danek, Inc. · SPACER 3992612 26MM X 12MM · Class 2 · Implant

All models of CAPSTONE PTC Spinal System (21)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00643169187405), received between Apr 18, 2022 and Sep 30, 2026 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1
  • Difficult to Advance1
  • Mechanics Altered1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 30, 2026Mechanics Altered

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50954594 ↗
  • MalfunctionMar 25, 2025Use of Device Problem; Use of Device Problem

    INFORMATION WAS RECEIVED FROM HEALTH CARE PROVIDER VIA MANUFACTURING REPRESENTATIVE REGARDING A PATIENT UNDERGONE SPINE SURGERY. IT WAS REPORTED THAT IMPLANT WAS EXPIRED. EXPIRED ON (B)(6) 2024. IMPLANT REMAINS IN PATIENT. NO PATIENT SYMPTOMS OR COMPLICATIONS ASSOCIATED WITH THIS EVENT. THE GRAFT WAS NOT RECEIVED FROM MEDTRONIC IN EXPIRED CONDITION, IT WAS EXPIRED IN IMPLANT SUITCASE AND WAS USER ERROR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21690311 ↗
  • MalfunctionApr 18, 2022Detachment of Device or Device Component; Difficult to Advance; Detachment of Device or Device Component; Difficult to Advance

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A SPACER USED IN UNKNOWN SPINAL THERAPY. IT WAS REPORTED THAT THERE WAS DEVICE DETACHMENT OUTSIDE THE PATIENT AFTER REMOVAL.  THERE WAS RESISTANCE ENCOUNTERED WHEN ADVANCING THE DEVICE. THERE WAS NO PATIENT SYMPTOM REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. UPDATED INFORMATION RECEIVED ON 08-APR-2022: THE USER FELT UNSTABLE BETWEEN CAPSTONE PEEK AND THREADED INSERTER WHEN HE IMPACT THE CAPSTONE PEEK INTERBODY SPACER, AND FIND OUT THE CAPSTONE PEEK SPLIT AFTER THEY IMPACT THE CAPSTONE PEEK INTERBODY SPACER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14133384 ↗

Other Intervertebral fusion device with bone graft, lumbar devices

All Intervertebral fusion device with bone graft, lumbar devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page