Skip to content

SPRINTER® LEGEND SPL12510XRecalls & reported problems

Medtronic, Inc. · BLN SPL12510X SPR LEG 1.25X10 RX US M · Class 2

All models of SPRINTER LEGEND (19)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00643169271753), received between Nov 6, 2017 and Nov 13, 2025 — classified as 3 injuries, 1 malfunction.

The most frequently reported specific device problem is “Burst Container or Vessel” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Burst Container or Vessel2
  • Detachment of Device or Device Component2
  • Adverse Event Without Identified Device or Use Problem1
  • Difficult to Remove1
  • Material Deformation1

Patient problems

  • Device Embedded In Tissue or Plaque2
  • Aneurysm1
  • No Consequences Or Impact To Patient1
  • Patient Problem/Medical Problem1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 13, 2025Difficult to Remove; Detachment of Device or Device Component; Material Deformation; Difficult to Remove; Detachment of Device or Device Component; Material Deformation

    IT WAS REPORTED THAT DURING A PROCEDURE INVOLVING ONE SPRINTER LEGEND RX BALLOON, THE BALLOON DETACHED DURING REMOVAL OF THE DEVICE FROM THE PATIENT. THE LESION BEING TREATED WAS A MODERATELY TORTUOUS, SEVERELY CALCIFIED WITH 100% CHRONIC TOTAL OCCLUSION (CTO) INTHE DISTAL OBTUSE MARGINAL (OM). THE DEVICE WAS INSPECTED PRIOR TO USE WITH NO ISSUES NOTED. NEGATIVE PREP WAS PERFORMED WITH NO ISSUES NOTED. THE LESION WAS NOT PRE-DILATED. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. RESISTANCE WAS ENCOUNTERED WHEN ADVANCING THE DEVICE. EXCESSIVE FORCE WAS NOT USED DURING DELIVERY. THE DEVICE WAS NOT KINKED AND RE-STRAIGHTENED DURING USE. THE SPRINTER LEGEND BALLOON WAS ADVANCED TO THE LESION SITE USING A TELESCOPE GUIDE EXTENSION CATHETER (GEC). THERE WERE MULTIPLE INFLATIONS TO 12ATM PERFORMED. UPON RETRIEVAL, THE SPRINTER LEGEND BALLOON SHEARED AT THE MARKER, RESULTING IN A PORTION OF THE MID MARKER AND SOME BALLOON MATERIAL REMAINING IN THE DISTAL END OF THE OBTUSE MARGINAL BRANCH. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 23542349 ↗
  • InjuryMay 15, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A SPRINTER LEGEND BALLOON CATHETER WAS USED TO PRE-DILATE A NON-TORTUOUS, NON-CALCIFIED LESION IN THE MID OM. THERE WAS NO DAMAGE NOTED TO THE DEVICE PACKAGING. THERE WERE NO ISSUES WHEN REMOVING THE DEVICE FROM THE HOOP/TRAY. THE DEVICE WAS INSPECTED WITH NO ISSUES. (B)(6) PREP WAS PERFORMED WITH NO ISSUES. THE LESION WAS PRE-DILATED. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED ST ENT. RESISTANCE WAS NOT ENCOUNTERED WHEN ADVANCING THE DEVICE. EXCESSIVE FORCE WAS NOT USED DURING DELIVERY. IT IS REPORTED THAT AS THE PHYSICIAN INFLATED THE BALLOON THEY NOTICED AN ANEURYSM HAD DEVELOPED PROXIMAL TO THE LESION. IT IS UNKNOWN IF THE BALLOON WAS THE CAUSE. THE PATIENT IS REPORTED AS BEING ALIVE WITHOUT INJURY.

    Patient problems: Aneurysm

    MAUDE report 7513478 ↗
  • InjuryMar 14, 2018Burst Container or Vessel; Detachment of Device or Device Component; Burst Container or Vessel; Detachment of Device or Device Component

    AN ATTEMPT WAS MADE TO USE A SPRINTER LEGEND RX BALLOON TO TREAT A CALCIFIED AND MODERATELY TORTUOUS LESION IN THE PROXIMAL LEFT CIRCUMFLEX WITH 90 % LESION STENOSIS. NO DAMAGE NOTED TO THE DEVICE PACKAGING. NO ISSUES WERE NOTED WHEN REMOVING THE DEVICE FROM THE HOOP/TRAY. THE DEVICE WAS INSPECTED AND NEGATIVE PREP WAS PERFORMED. THE LESION WAS PRE-DILATED. A ROTOBLATOR WAS USED IN THE DISTAL LEFT MAIN INTO LAD TO TREAT THE CALCIFIED LESION FOLLOWED BY A 2.0 MM AND A 3.0 MM NON-MEDTRONIC BALLOONS. THE NON-MEDTRONIC BALLOONS WERE USED PRIOR TO USING THE SPRINTER LEGEND 1.25 MM, BUT BOTH NON-MEDTRONIC BALLOONS DID NOT CROSS. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. IT WAS REPORTED THAT A BALLOON BURST/LEAK OCCURRED. THE BALLOON BURST IN THE PROXIMAL LEFT CIRCUMFLEX AT 18 ATM. IT WAS REPORTED THAT THE MARKER BAND DISLODGED AFTER DEPLOYMENT IN THE PROXIMAL LEFT CIRCUMFLEX. IT WAS OBSERVED THAT THE MARKER BAND MIGRATED FROM THE PROXIMAL LEFT CIRCUMFLEX TO A BRANCH OF THE LEFT CIRCUMFLEX. AN ATTEMPT WAS MADE TO RECOVER THE DISLODGED MARKER BAND. A NON-MEDTRONIC CATHETER WAS ADVANCED OVER THE TIP OF THE BALLOON CATHETE R, IN THE LEFT CX, THEN THE NON-MEDTRONIC CATHET

    Patient problems: Device Embedded In Tissue or Plaque; Patient Problem/Medical Problem

    MAUDE report 7337095 ↗
  • MalfunctionNov 6, 2017Burst Container or Vessel; Burst Container or Vessel

    THE PHYSICIAN INTENDED TO USE A SPRINTER LEGEND BALLOON CATHETER TO TREAT A MODERATELY TORTUOUS, SEVERELY CALCIFIED LESION WITH 95% STENOSIS IN THE MID LAD. THERE WAS NO DAMAGE NOTED TO PACKAGING AND NO ISSUES NOTED WHEN REMOVING THE DEVICE FROM THE HOOP/TRAY. THE DEVICE WAS NOT INSPECTED AND NEGATIVE PREP WAS PERFORMED WITH NO ISSUES. THE LESION WAS NOT PRE-DILATED. RESISTANCE WAS NOT ENCOUNTERED WHEN ADVANCING THE DEVICE AND EXCESSIVE FORCE WAS NOT USED DURING DELIVERY. THERE WERE NO ABNORMALITIES IN ANATOMY. IT IS REPORTED THAT A BALLOON BURST OR LEAK OCCURRED ON THE FIRST INFLATION AFTER 12 ATM OF PRESSURE HAD BEEN APPLIED. THE BALLOON BURST WHILE BEING EXPANDED IN THE PATIENT WITH HEAVY CALCIUM. THE DEVICE WAS BEING USED TO PRE-DILATE THE LESION. THE DEVICE WAS NOT MOVED OR RE-POSITIONED PRIOR TO THE BURST. THE DEVICE WAS REPLACED BY ANOTHER MANUFACTURERS PRODUCT. NO PATIENT INJURY IS REPORTED.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7002961 ↗

Other Catheters, transluminal coronary angioplasty, percutaneous devices

All Catheters, transluminal coronary angioplasty, percutaneous devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page