Open Pivot™ 500DM25 (UDI 00643169335042)Recalls & reported problems
Medtronic, Inc. · MHV 500DM25 STD MITRAL · Class 3 · Implant
All models of Open Pivot (42)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 1
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00643169335042), received between Jun 26, 2017 and Mar 4, 2021 — classified as 1 death, 4 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (3 reports).
2 other recalls cover devices cleared under the same FDA submission (P990046); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Insufficient Device Problem Information3
- Adverse Event Without Identified Device or Use Problem2
- Inadequacy of Device Shape and/or Size1
- Off-Label Use1
Patient problems
- No Information3
- Death1
- Heart Block1
- Non specific EKG/ECG Changes1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryMar 4, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MEDTRONIC RECEIVED INFORMATION THAT 3 DAYS POST IMPLANT OF THIS 25MM MECHANICAL MITRAL VALVE, A PERMANENT PACEMAKER WAS IMPLANTED IN THE PATIENT. THE REASON FOR THE PERMANENT PACEMAKER IMPLANT WAS REPORTED AS COMPLETE HEART BLOCK WITH SICK SINUS SYNDROME. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Heart Block; Non specific EKG/ECG Changes
MAUDE report 11416735 ↗InjuryAug 19, 2019Off-Label Use; Insufficient Device Problem Information; Off-Label Use; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT THIS 25MM MITRAL ANNULOPLASTY BAND WAS IMPLANTED AND EXPLANTED DURING THE PROCEDURE FOR UNKNOWN REASONS. IT WAS REPLACED WITH A 25MM MITRAL MECHANICAL VALVE. THREE DAYS LATER THE PATIENT ALSO HAD A TRICUSPID BIOPROSTHETIC VALVE IMPLANTED AND LATER THAT DAY PASSED AWAY. NO CAUSE OF DEATH HAS BEEN RECEIVED AT THIS TIME.
Patient problems: No Information
MAUDE report 8906136 ↗InjuryJan 6, 2019Inadequacy of Device Shape and/or Size; Insufficient Device Problem Information; Inadequacy of Device Shape and/or Size; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT THIS 25MM MITRAL MECHANICAL VALVE WAS IMPLANTED AND EXPLANTED DURING THE SAME PROCEDURE. THE DEVICE WAS REPLACED WITH A 24MM MECHANICAL VALVE FOR UNKNOWN REASONS. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information
MAUDE report 8220646 ↗DeathAug 15, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS 29 MM MECHANICAL VALVE IN A PATIENT WITH RHEUMATIC VALVE DISEASE, DUE TO ANNULAR RUPTURE, THE VALVE WAS EXPLANTED AND REPLACED WITH A 25 MM VALVE OF THE SAME MODEL. SUBSEQUENTLY THE PATIENT DIED. IT WAS REPORTED THAT THE DEATH WAS NOT RELATED TO THE VALVE OR ITS FUNCTION NOR WAS THERE ANY ALLEGATION THAT THE VALVE CONTRIBUTED TO THE PATIENT'S DEATH.
Patient problems: Death
MAUDE report 6793984 ↗InjuryJun 26, 2017Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT FOUR MONTHS FOLLOWING THE IMPLANT OF THIS MECHANICAL VALVE IN THE MITRAL POSITION, THIS DEVICE WAS EXPLANTED AND REPLACED WITH A BIOPROSTHETIC MITRAL VALVE. NO FAILURE MECHANISM AND NO OTHER ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Information
MAUDE report 6668700 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P990046. One submission often covers many models, so check the product and lot details in each record.
- Z-1533-2020 · Feb 11, 2020 · TerminatedMedtronic Open Pivot Aortic Valve Graft, REF 502AG25, SIZE 25 mm
- Z-0634-04 · Feb 18, 2004 · TerminatedATS Open Pivot Mechanical Heart Valve
Other HEART-VALVE, MECHANICAL devices
- On-X Mitral Heart Valve with Conform-X Sewing Ring ONXMC-25/33On-X Life Technologies, Inc. · Heart-Valve, Mechanical1 recall1 death34 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths70 reports
- SJM Regent™ AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL5 deaths66 reports
- SJM Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths44 reports
- CARBOMEDICS SUPRA-ANNULAR (TOP HAT) S5-021Corcym Srl · HEART-VALVE, MECHANICAL7 deaths37 reports
- Regent™ 21AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL3 deaths35 reports
- Regent™ 23AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL2 deaths33 reports
- Regent™ 19AGFN-756St. Jude Medical, Inc. · HEART-VALVE, MECHANICAL31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page