VALIANT® Captivia VAMC4646C100TURecalls & reported problems
Medtronic, Inc. · STENT GRAFT VAMC4646C100TU VALCAP CLOSE · Class 3 · Implant
All models of VALIANT Captivia (95)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00643169346642), received between May 12, 2017 and Mar 23, 2018 — classified as 2 injuries.
The most frequently reported specific device problem is “Leak/Splash” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Leak/Splash2
- Migration or Expulsion of Device1
Patient problems
- Injury1
- Pain1
- Rupture1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryMar 23, 2018Leak/Splash; Leak/Splash
AN ENDURANT II STENT GRAFT SYSTEM AND A VALIANT STENT GRAFT WERE IMPLANTED IN A PATIENT FOR THE ENDOVASCULAR TREATMENT OF AN UNKNOWN SIZE ABDOMINAL AND THORACIC AORTIC ANEURYSMAL DISEASE. THE PATIENT'S PARTNER REPORTED THAT THE STENT GRAFTS HAD LEAKED AND A TOTAL BYPASS AND REPAIR WAS PERFORMED. NO ADDITIONAL CLINICAL SEQUELAE WERE REPORTED AND THE PATIENT IS FINE.
Patient problems: Injury
MAUDE report 7365445 ↗InjuryMay 12, 2017Leak/Splash; Migration or Expulsion of Device; Leak/Splash; Migration or Expulsion of Device
A VALIANT CAPTIVIA STENT GRAFT SYSTEM WAS IMPLANTED IN A PATIENT FOR THE ENDOVASCULAR TREATMENT OF A 9.2 CM IN DIAMETER THORACIC AORTIC ANEURYSM. IT WAS REPORTED THAT THE PATIENT PRESENTED EMERGENTLY WITH BACK PAIN. THE CT SHOWED THAT THE DISTAL VALIANT STENT GRAFT HAD MIGRATED PROXIMALLY AWAY FROM THE CELIAC ARTERY WITH A DISTAL TYPE I ENDOLEAK AND ANEURYSM RUPTURE. THE PHYSICIAN ELECTED TO SNORKEL THE SMA AND RIGHT RENAL. ANOTHER MANUFACTURER¿S STENT WERE IMPLANTED INTO THE SMA AND RIGHT RENAL AND ANOTHER VALIANT STENT GRAFT WAS IMPLANTED. THE FINAL ANGIOGRAM SHOW THAT THE SNORKELS WERE PATENT AND THE MIGRATION AND DISTAL TYPE I ENDOLEAK WERE RESOLVED. PER THE PHYSICIAN, THE CAUSE OF THE MIGRATION AND DISTAL TYPE I ENDOLEAK IS RELATED TO THE PATIENT¿S ANATOMY, EXPANSION OF THE DISTAL THORACIC AORTA. NO ADDITIONAL CLINICAL SEQUELAE WERE REPORTED AND THE PATIENT IS FINE.
Patient problems: Pain; Rupture
MAUDE report 6563945 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page