ANATOMIC PEEK PTC Cervical Fusion System 5030141Recalls & reported problems
Medtronic Sofamor Danek, Inc. · CAGE 5030141 ANATOMIC PTC 14X11X11MM · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169357624), received between Apr 11, 2024 and Apr 11, 2024 — classified as 1 injury.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Migration1
Patient problems
- Discomfort1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 11, 2024Migration; Migration
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING REVISION SURGERY. PRE-OP DIAGNOSIS WAS CERVICAL KYPHOSIS. IT WAS REPORTED THAT, PATIENT HAD DISCOMFORT DUE TO PLATE DISLODGEMENT. AFTER C5/6 DECOMPRESSION, 11MM CAGE WAS PLACED AND MIGRATION OF C5/6 CAGE ALREADY OCCURRED AFTER COMBINED POSTERIOR FIXATION. AFTER 1 WEEK POSTOPERATIVELY, FURTHER MIGRATION OF THE CAGE AND HEAD SIDE DISLODGEMENT OF THE C4-7 ZEVO PLATE OCCURRED. TOTAL REMOVAL OF PLATE AND REMOVAL OF 11MM CAGE AT C5/6, AUTOLOGOUS ILIAC BONE TRANSPLANTATION BETWEEN C5/6 VERTEBRAE WAS RETRIEVED DURING REVISION SURGERY. THE 13MM SCREW AT C4 AND 15MM SCREW AT C7 WAS FOUND LOOSE AND THEY WERE EXPLANTED. PROCEDURE OR TECHNIQUE PERFORMED DURING INITIAL SURGERY WAS C4-7 ANTERIOR CERVICAL DISCECTOMY AND FUSION. THERE WERE NO PARTICULAR PROBLEMS WITH 5MM CAGE. NO FURTHER COMPLICATIONS REPORTED.
Patient problems: Discomfort
MAUDE report 19094240 ↗
Other Intervertebral fusion device with bone graft, cervical devices
- ROI-C MC1005TLDR Spine Usa, Inc. · Intervertebral Fusion Device With Bone Graft, Cervical54 reports
- EIT CIF cage CUI8070SEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall4 reports
- EIT CIF cage CUI8060LEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall1 report
- CONSTRUX - MINI Ti 37-7212SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8015SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-7206SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8007SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI PTC 37-4211SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.