Medtronic Sofamor Danek, Inc. · DRIVER 6630904 T8/T10 DRIVER · Class 1

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00643169363496), received between Jan 9, 2019 and Mar 4, 2025 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Break” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 3 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break5

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Device Embedded In Tissue or Plaque1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 4, 2025Break; Break

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY. IT WAS REPORTED THAT TIP OF DRIVER BROKE WHILE LOCKING A SCREW. THERE WAS NO PATIENT SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21512261 ↗
  • MalfunctionFeb 12, 2025Break; Break

    INFORMATION WAS RECEIVED FROM HEALTH CARE PROVIDER VIA MANUFACTURING REPRESENTATIVE REGARDING A PRODUCT IDENTIFIED DURING AN EVENT. IT WAS REPORTED THAT DRIVERS WERE STRIPPED. NO PATIENT SYMPTOMS WERE REPORTED. NO FURTHER COMPLICATIONS WERE REPORTED/ANTICIPATED. (B)(6) 2023 E1 (REP): PRODUCT CAME IN CONTACT WITH PATIENT, PROCEDURE WAS C3-5 ACDF CORPECTOMY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21362288 ↗
  • MalfunctionFeb 4, 2025Break; Break

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY FOR UNKNOWN INDICATION. IT WAS REPORTED THAT THE PART OF THE TIP OF ONE OF THE REPORTED DRIVERS BROKE OFF WHILE THE SURGEON WAS TRYING TO LOCK THE PLATE. THE PIECE WAS RECOVERED AND DISCARDED. NO PART OF THE INSTRUMENT REMAINS IN THE PATIENT. THE OTHER TWO DRIVERS WERE STRIPPED. THE PROCEDURE WAS COMPLETED WITH NEW DRIVERS. THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21301338 ↗
  • MalfunctionFeb 3, 2025Break; Break

    INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER (HCP) VIA A MEDTRONIC REPRESENTATIVE REGARDING THE DRIVERS USED IN THE C5-7 ANTERIOR CERVICAL DISCECTOMY AND FUSION (ACDF) SURGERY FOR DEGENERATIVE DISC DISEASE AT C5-7. IT WAS REPORTED THAT THE TIP OF THE T8 DRIVER WAS BROKEN OFF DURING AN ATTEMPT TO LOCK THE ZEVO LOCK PLATE. THE TIP WAS NOT RECOVERED BUT MOST LIKELY WAS SUCKED UP INTO THE SUCTION. NO PIECE OF THE DRIVER WAS FOUND IN THE PATIENT. THE ZEVO DRIVERS WAS STRIPPED AND NO LONGER USABLE WHILE IMPLANTING ZEVO SCREWS. NO ADVERSE EVENT OCCURRED TO PATIENT. THERE WERE NO FURTHER COMPLICATIONS THAT WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21293491 ↗
  • MalfunctionJan 9, 2019Break; Break

    IT WAS REPORTED THAT THE PATIENT WAS PRE-OPERATIVELY DIAGNOSED WITH DEGENERATIVE DISC DISEASE. DURING SURGERY, THE TIP OF THE DRIVER BROKE. THE TIP OF THE DRIVER IS STILL IN THE PLATE, LOCATED IN THE PATIENT. THE SURGEON WAS NOT ABLE TO REMOVE THE BROKEN TIP DURING THE PROCEDURE. THERE WILL NOT BE ANY SUBSEQUENT SURGERY TO RECOVER THE BROKEN TIP AS IT IS LODGED DIRECTLY INTO THE IMPLANT.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 8230136 ↗

Other SCREWDRIVER devices

All SCREWDRIVER devices →