ZEVO™ Anterior Cervical Plate System G7703513Recalls & reported problems
Medtronic Sofamor Danek, Inc. · SCREW G7703513 ZEVO VAR SD 3.5MM X 13MM · Class 2 · Implant
All models of ZEVO Anterior Cervical Plate System (39)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 00643169398504), received between Jun 27, 2020 and May 8, 2024 — classified as 5 injuries.
The most frequently reported specific device problem is “Expulsion” (4 reports).
1 other recall cover devices cleared under the same FDA submission (K141632); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Expulsion4
- Device Dislodged or Dislocated1
Patient problems
- Pain4
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryMay 8, 2024Device Dislodged or Dislocated; Device Dislodged or Dislocated
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A REPEAT SURGERY. THE INITIAL SURGERY WAS A C4-7 CERVICAL SPINE ANTERIOR FUSION SURGERY. IT WAS REPORTED THAT A DV SCREW WAS USED IN C4 (LEFT AND UNKNOWN FOR LEFT/RIGHT BUT PERHAPS RIGHT) AND C7 (RIGHT) FOR EACH OF THEM WITH A FORWARD FIXED ZEVO PLATE. THE DV SCREW AND THE ZV SCREW WERE MISTAKENLY DELIVERED TO NURSES AND WERE INSERTED WITH A ZV SCREWDRIVER. AS A RESULT, ONLY C7 ON THE ZEVO PLATE COULD NOT CLOSE THE LOCKING CAP, AND IT WAS SUGGESTED THAT FOR SEALS, THE SCREW SHOULD BE INSERTED DEEPER OR THE ANGLE (ORBIT) OF THE INSIDE/OUTSIDE SHOULD BE CHANGED. SINCE THE "SCREW LIFTED OFF," THE WOUND CLOSURE/SURGICAL INCISION CLOSURE WAS MADE WITHOUT TURNING THE LOCKING CAP AT THE DOCTOR'S DISCRETION. THE CAUSE MIGHT BE THAT THE DV SCREW WAS USED. THE WOUND CLOSURE/SURGICAL INCISION CLOSURE WAS DONE AND SCREW WAS NOT REPLACED. THERE WAS NO PATIENT SYMPTOM REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19266219 ↗InjuryJun 27, 2020Expulsion; Expulsion
IT WAS REPORTED THAT THE PATIENT PRESENTED WITH CERVICAL SPONDYLOTIC MYELOPATHY; AND UNDERWENT ANTERIOR CERVICAL DISCECTOMY AND FUSION AT C4-C6 AND CORPECTOMY WAS PERFORMED AT C5. ON AN UNKNOWN DATE, POST-OP, THE ALLEGED SCREW ALONG WITH 3 MORE SCREWS BACKED-OUT. SINKING OF A TITANIUM MESH IMPLANT WAS ALSO OBSERVED. THE PATIENT SOMETIMES EXPERIENCED RIGHT SHOULDER PAIN AROUND THE TIME WHEN SINKING OF THIS MESH IMPLANT WAS REPORTED. HENCE, THE PATIENT UNDERWENT A REVISION SURGERY, IN WHICH ALL THE 4 BACKED-OUT SCREWS WERE REMOVED AND WERE REPLACED WITH LONGER SCREWS. THE ANTERIOR PLATE (THAT WAS INSERTED IN THE PREVIOUS SURGERY) CAME OFF TOGETHER WITH THE SCREWS AND WAS USED AGAIN BY PERFORMING FIXATION WITH LONGER SCREWS. ALTHOUGH THERE WAS SINKING OF MESH IMPLANT, IT APPEARED TO BE FIT IN ITS POSITION; HENCE, IT WAS NOT REMOVED AND WAS LEFT IMPLANTED IN THE PATIENT'S BODY. "LMS" WAS INSERTED FROM POSTERIOR SIDE INTO C4-C6 AND WAS FASTENED WITH ROD AND CROSSLINK.
Patient problems: Pain
MAUDE report 10204283 ↗InjuryJun 27, 2020Expulsion; Expulsion
IT WAS REPORTED THAT THE PATIENT PRESENTED WITH CERVICAL SPONDYLOTIC MYELOPATHY; AND UNDERWENT ANTERIOR CERVICAL DISCECTOMY AND FUSION AT C4-C6 AND CORPECTOMY WAS PERFORMED AT C5. ON AN UNKNOWN DATE, POST-OP, THE ALLEGED SCREW ALONG WITH 3 MORE SCREWS BACKED-OUT. SINKING OF A TITANIUM MESH IMPLANT WAS ALSO OBSERVED. THE PATIENT SOMETIMES EXPERIENCED RIGHT SHOULDER PAIN AROUND THE TIME WHEN SINKING OF THIS MESH IMPLANT WAS REPORTED. HENCE, THE PATIENT UNDERWENT A REVISION SURGERY, IN WHICH ALL THE 4 BACKED-OUT SCREWS WERE REMOVED AND WERE REPLACED WITH LONGER SCREWS. THE ANTERIOR PLATE (THAT WAS INSERTED IN THE PREVIOUS SURGERY) CAME OFF TOGETHER WITH THE SCREWS AND WAS USED AGAIN BY PERFORMING FIXATION WITH LONGER SCREWS. ALTHOUGH THERE WAS SINKING OF MESH IMPLANT, IT APPEARED TO BE FIT IN ITS POSITION; HENCE, IT WAS NOT REMOVED AND WAS LEFT IMPLANTED IN THE PATIENT'S BODY. "LMS" WAS INSERTED FROM POSTERIOR SIDE INTO C4-C6 AND WAS FASTENED WITH ROD AND CROSSLINK.
Patient problems: Pain
MAUDE report 10204281 ↗InjuryJun 27, 2020Expulsion; Expulsion
IT WAS REPORTED THAT THE PATIENT PRESENTED WITH CERVICAL SPONDYLOTIC MYELOPATHY; AND UNDERWENT ANTERIOR CERVICAL DISCECTOMY AND FUSION AT C4-C6 AND CORPECTOMY WAS PERFORMED AT C5. ON AN UNKNOWN DATE, POST-OP, THE ALLEGED SCREW ALONG WITH 3 MORE SCREWS BACKED-OUT. SINKING OF A TITANIUM MESH IMPLANT WAS ALSO OBSERVED. THE PATIENT SOMETIMES EXPERIENCED RIGHT SHOULDER PAIN AROUND THE TIME WHEN SINKING OF THIS MESH IMPLANT WAS REPORTED. HENCE, THE PATIENT UNDERWENT A REVISION SURGERY, IN WHICH ALL THE 4 BACKED-OUT SCREWS WERE REMOVED AND WERE REPLACED WITH LONGER SCREWS. THE ANTERIOR PLATE (THAT WAS INSERTED IN THE PREVIOUS SURGERY) CAME OFF TOGETHER WITH THE SCREWS AND WAS USED AGAIN BY PERFORMING FIXATION WITH LONGER SCREWS. ALTHOUGH THERE WAS SINKING OF MESH IMPLANT, IT APPEARED TO BE FIT IN ITS POSITION; HENCE, IT WAS NOT REMOVED AND WAS LEFT IMPLANTED IN THE PATIENT'S BODY. "LMS" WAS INSERTED FROM POSTERIOR SIDE INTO C4-C6 AND WAS FASTENED WITH ROD AND CROSSLINK.
Patient problems: Pain
MAUDE report 10204279 ↗InjuryJun 27, 2020Expulsion; Expulsion
IT WAS REPORTED THAT THE PATIENT PRESENTED WITH CERVICAL SPONDYLOTIC MYELOPATHY; AND UNDERWENT ANTERIOR CERVICAL DISCECTOMY AND FUSION AT C4-C6 AND CORPECTOMY WAS PERFORMED AT C5. ON AN UNKNOWN DATE, POST-OP, THE ALLEGED SCREW ALONG WITH 3 MORE SCREWS BACKED-OUT. SINKING OF A TITANIUM MESH IMPLANT WAS ALSO OBSERVED. THE PATIENT SOMETIMES EXPERIENCED RIGHT SHOULDER PAIN AROUND THE TIME WHEN SINKING OF THIS MESH IMPLANT WAS REPORTED. HENCE, THE PATIENT UNDERWENT A REVISION SURGERY, IN WHICH ALL THE 4 BACKED-OUT SCREWS WERE REMOVED AND WERE REPLACED WITH LONGER SCREWS. THE ANTERIOR PLATE (THAT WAS INSERTED IN THE PREVIOUS SURGERY) CAME OFF TOGETHER WITH THE SCREWS AND WAS USED AGAIN BY PERFORMING FIXATION WITH LONGER SCREWS. ALTHOUGH THERE WAS SINKING OF MESH IMPLANT, IT APPEARED TO BE FIT IN ITS POSITION; HENCE, IT WAS NOT REMOVED AND WAS LEFT IMPLANTED IN THE PATIENT'S BODY. "LMS" WAS INSERTED FROM POSTERIOR SIDE INTO C4-C6 AND WAS FASTENED WITH ROD AND CROSSLINK.
Patient problems: Pain
MAUDE report 10204277 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K141632. One submission often covers many models, so check the product and lot details in each record.
- Z-1750-2018 · Mar 23, 2018 · TerminatedMedtronic ZEVO(TM) Anterior Cervical Plate System SLOT SCREW, REF 7710015, Size 4.5mm x 15mm Product Appliance, fixation, spinal intervertebral body
Other APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- XLP 7565050Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430344Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- ATLANTIS® Anterior Cervical Plate System 876-170Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- XLP 7565060Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430113Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page