CoreValve™ Evolut™ MCS-P3-31-AOA-USRecalls & reported problems
Medtronic Corevalve LLC · VALVE MCS-P3-31-AOA-US TAV 31 US COMM MX · Class 3 · Implant
All models of Medtronic Evolut TAVR (45) · CoreValve Evolut (9)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This Medtronic CoreValve Evolut is a replacement aortic valve delivered through a catheter to replace a damaged heart valve without open surgery. Most of the 66 reports describe valve trouble years after implantation — leaking around or through the valve, narrowing or failure of the valve, or the valve being positioned incorrectly — often leading to a second valve or surgical valve being placed. Reports include 60 injuries and no deaths. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 65
- Deaths reported
- 0
- Injuries reported
- 59
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 65 adverse event reports that list this exact device (DI 00643169448551), received between Jun 22, 2015 and Mar 20, 2026 — classified as 59 injuries, 6 malfunctions.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (14 reports).
4 other recalls cover devices cleared under the same FDA submission (P130021); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem28
- Insufficient Device Problem Information14
- Perivalvular Leak10
- Device Stenosis8
- Patient Device Interaction Problem8
- Malposition of Device5
- Device Dislodged or Dislocated3
- Gradient Increase3
Patient problems
- Non specific EKG/ECG Changes12
- Insufficient Information10
- No Clinical Signs, Symptoms or Conditions8
- Aortic Valve Stenosis7
- No Known Impact Or Consequence To Patient6
- Aortic Valve Insufficiency/ Regurgitation5
- Heart Block5
- Complete Heart Block4
Recent adverse event reports
The 25 most recent of 65 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 20, 2026Insufficient Device Problem Information
IT WAS REPORTED THAT APPROXIMATELY 10 YEARS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, THE VALVE FAILED DUE TO AN UNSPECIFIED CAUSE. THE PATIENT IS BEING EVALUATED FOR POTENTIAL TREATMENT OPTIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24650479 ↗InjuryMar 17, 2026Insufficient Device Problem Information
IT WAS REPORTED THAT APPROXIMATELY 10 YEARS AND 3 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, THE VALVE WAS INACTIVATED FOR AN UNSPECIFIED REASON. SUBSEQUENTLY, A SECOND VALVE WAS IMPLANTED.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 24617743 ↗InjuryJan 30, 2026Insufficient Device Problem Information
IT WAS REPORTED APPROXIMATELY 8 YEARS AND 1 MONTH FOLLOWING THE IMPLANT OF THIS TRANSCATHETER AORTIC VALVE, THE VALVE WAS EXPLANTED FOR AN UNKNOWN REASON. SUBSEQUENTLY, A SURGICAL TISSUE VALVE WAS IMPLANTED.
Patient problems: Insufficient Information
MAUDE report 24225398 ↗MalfunctionNov 24, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT APPROXIMATELY 10 YEARS AND 2 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, UNSPECIFIED VALVE FAILURE WAS OBSERVED. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23631485 ↗InjuryAug 28, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
MEDTRONIC RECEIVED INFORMATION THAT DURING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, VENTRICULAR FIBRILLATION WAS REPORTED AND CARDIOVERSION WAS PERFORMED ONCE. FOLLOWING THE VALVE IMPLANT PROCEDURE, LEFT BUNDLE BRANCH BLOCK (LBBB) AND SINUS BRADYCARDIA WERE NOTED. A TEMPORARY PACING WIRE WAS PLACED AND MEDICATION WAS ADJUSTED. HYPOTENSION WAS REPORTED DUE TO VOLUME DEPLETION AND PRESSORS WERE PRESCRIBED. NO FURTHER ADVERSE PATIENT EFFECTS WERE REPORTED. ADDITIONAL INFORMATION WAS REPORTED THAT NO TREATMENT WAS PROVIDED FOR THE LBBB. PER THE PHYSICIAN, THE LBBB WAS RELATED TO THE VALVE AND VALVE IMPLANT PROCEDURE. APPROXIMATELY SIX MONTHS FOLLOWING ONSET, THE LBBB RESOLVED, WITHOUT SEQUELAE. ADDITIONAL INFORMATION WAS REPORTED THAT A PERMANENT PACEMAKER WAS IMPLANTED THREE DAYS FOLLOWING THE IMPLANT OF THE VALVE FOR BRADYCARDIA. BRADYCARDIA RESOLVED WITH NO SEQUELAE ONE DAY FOLLOWING THE IMPLANT OF THE PERMANENT PACEMAKER. PER THE PHYSICIAN, THE BRADYCARDIA EVENT WAS RELATED TO THE VALVE AND THE VALVE IMPLANT PROCEDURE.
Patient problems: Bradycardia; Low Blood Pressure/ Hypotension; Non specific EKG/ECG Changes; Ventricular Fibrillation
MAUDE report 22915018 ↗InjuryJun 13, 2025Fluid/Blood Leak; Gradient Increase; Perivalvular Leak; Fluid/Blood Leak; Gradient Increase; Perivalvular Leak
ADDITIONAL INFORMATION RECEIVED INDICATED THAT UNSPECIFIED REGURGITATION WAS ALSO PRESENT. AN UNSPECIFIED VALVE INTERVENTION OCCURRED APPROXIMATELY 2 MONTHS FOLLOWING ONSET OF THIS EVENT. HOSPITALIZATION WAS REQUIRED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Dyspnea; Transvalvular Pressure Gradient Increased
MAUDE report 22202491 ↗MalfunctionJun 2, 2025Device Stenosis; Device Stenosis
IT WAS REPORTED THAT APPROXIMATELY 10 YEARS AND 1 MONTH FOLLOWING THE IMPLANT OF A TRANSCATHETER VALVE, THE VALVE FAILED DUE TO STENOSIS. SUBSEQUENTLY, THE PATIENT WAS BEING EVALUATED FOR A TAV-IN-TAV OR EXPLANT PROCEDURE. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Stenosis
MAUDE report 22125938 ↗InjuryJan 8, 2025Device Stenosis; Device Stenosis
IT WAS REPORTED THAT APPROXIMATELY 9 YEARS AND 4 MONTHS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, VALVE STENOSIS WAS NOTED. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT. ADDITIONAL INFORMATION WAS RECEIVED THAT A NON-MEDTRONIC VALVE WAS IMPLANTED VALVE-IN-VALVE AS TREATMENT FOR THE STENOSIS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21106207 ↗MalfunctionJan 7, 2025Thickening of Material; Device Stenosis; Thickening of Material; Device Stenosis
MEDTRONIC RECEIVED INFORMATION THAT SEVEN YEARS AND EIGHT MONTHS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, THE PATIENT WAS EVALUATED FOR A TRANSCATHETER VALVE REPLACEMENT. IT WAS NOTED THE VALVE WAS FAILING DUE TO STENOSIS AND LIKELY HYPOATTENUATING LEAFLET THICKENING. NO TREATMENT WAS REPORTED. NO ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis
MAUDE report 21093704 ↗InjuryJan 2, 2025Device Stenosis; Device Stenosis
IT WAS REPORTED THAT APPROXIMATELY 8 YEARS AND 8 MONTHS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER AORTIC VALVE, VALVE STENOSIS WAS NOTED. A TRANSCATHETER AORTIC VALVE-IN-VALVE PROCEDURE WITH A NON-MEDTRONIC VALVE WAS PLANNED AS TREATMENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21057820 ↗InjuryNov 19, 2024Device Stenosis; Device Stenosis
ADDITIONAL INFORMATION WAS RECEIVED THAT THE VALVE WAS EXPLANTED DUE TO SEVERE AORTIC STENOSIS. A SURGICAL VALVE WAS SUBSEQUENTLY IMPLANTED.
Patient problems: Aortic Valve Stenosis; Heart Failure/Congestive Heart Failure
MAUDE report 20727643 ↗InjuryOct 2, 2024Perivalvular Leak; Patient Device Interaction Problem; Perivalvular Leak; Patient Device Interaction Problem
ADDITIONAL INFORMATION WAS RECEIVED THAT INDICATED THE PHYSICIAN ASSESSED THE SECOND VALVE¿S MILD TO MODERATE PVL AS RELATED TO THE VALVE AND NOT RELATED TO THE VALVE IMPLANT PROCEDURE.
Patient problems: Atrial Fibrillation; Heart Failure/Congestive Heart Failure; Non specific EKG/ECG Changes; Pulmonary Dysfunction; Swelling/ Edema; Tachycardia; Thrombocytopenia; Valvular Insufficiency/ Regurgitation
MAUDE report 20352612 ↗InjurySep 12, 2024Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem; Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem
MEDTRONIC RECEIVED INFORMATION THAT SEVEN DAYS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, A BIVENTRICULAR DEFIBRILLATOR WAS IMPLANTED DUE TO A LOW EJECTION FRACTION AND DYSSYNCHRONY WITH A WIDE QRS INTERVAL. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Non specific EKG/ECG Changes
MAUDE report 20199844 ↗InjurySep 6, 2024Intravalvular regurgitation; Intravalvular regurgitation
MEDTRONIC RECEIVED INFORMATION THAT AN UNKNOWN AMOUNT OF TIME FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, THE VALVE FAILED. THE MECHANISM OF FAILURE WAS CENTRAL AORTIC REGURGITATION (AR). A SECOND VALVE WAS PLACED AS TREATMENT. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 20155351 ↗InjurySep 6, 2024Insufficient Device Problem Information; Device Stenosis; Insufficient Device Problem Information; Device Stenosis
MEDTRONIC RECEIVED INFORMATION THAT 8 YEARS 8 MONTHS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, THE VALVE FAILED. THE MECHANISM OF FAILURE WAS NOT REPORTED. NO ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions; Stenosis
MAUDE report 20155292 ↗InjuryApr 10, 2024Device Stenosis; Device Stenosis
ADDITIONAL INFORMATION WAS RECEIVED THAT THE VALVE WAS EXPLANTED APPROXIMATELY EIGHT YEARS POST VALVE IMPLANT.
Patient problems: Aortic Valve Stenosis; No Clinical Signs, Symptoms or Conditions
MAUDE report 19077050 ↗MalfunctionMar 27, 2024Insufficient Device Problem Information; Device Stenosis; Insufficient Device Problem Information; Device Stenosis
ADDITIONAL INFORMATION WAS RECEIVED THAT THE VALVE FAILURE WAS AORTIC STENOSIS.
Patient problems: Aortic Valve Stenosis; Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 18988267 ↗InjuryDec 21, 2023Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem; Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem
MEDTRONIC RECEIVED INFORMATION THAT 4 DAYS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, THE PATIENT HAD ATRIAL ARRHYTHMIA WHICH NECESSITATED THE IMPLANT OF A PERMANENT PACEMAKER. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Arrhythmia
MAUDE report 18377000 ↗InjuryDec 8, 2023Fluid/Blood Leak; Patient Device Interaction Problem; Fluid/Blood Leak; Patient Device Interaction Problem
MEDTRONIC RECEIVED INFORMATION THAT APPROXIMATELY 7 YEARS, 11 AND A HALF MONTHS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, THE PATIENT PRESENTED TO THE EMERGENCY DEPARTMENT WITH COMPLAINT OF SHORTNESS OF BREATH AND FATIGUE. DIAGNOSTIC TESTING INCLUDED A SCHEDULED NON-CONTRAST COMPUTED TOMOGRAPHY AND A TRANSTHORACIC ECHOCARDIOGRAM TO RULE OUT STENOSIS AND THROMBOSIS OF THE DISLODGED VALVE. REVIEW OF THE TRANSTHORACIC ECHOCARDIOGRAM SHOWED LT VENTRICLE: MODERATE CONCENTRIC HYPERTROPHY. ESTIMATED EJECTION FRACTION WAS (B)(4). VENTRICULAR PACING FROM THE PERMANENT PACEMAKER. LEFT ATRIUM: SEVERELY DILATED. RT ATRIUM: MODERATELY DILATED. MILD TRICUSPID REGURGITATION. TRIVIAL MITRAL REGURGITATION. TRANSVALVULAR VELOCITY WAS WITHIN NORMAL VALVE LIMITS. THE AORTIC VALVE STRUCTURE AND FUNCTION WERE NORMAL, NO EVIDENCE OF STENOSIS; THERE WAS NO VALVULAR INSUFFICIENCY OR PARAVALVULAR LEAK. LABORATORY RESULTS FROM BLOOD TESTS SHOWED THE WHITE BLOOD CELL (WBC) COUNT, BLOOD UREA NITROGEN (BUN), CREATININE, ASPARTATE AMINOTRANSFERASE (AST), INTERNATIONAL NORMALIZED RATIO (INR), CREATINE KINASE (CK), AND TROPONIN WERE ABOVE NORMAL LIMITS AT ADMISSION. SUBSEQUENTLY, THE PATIENT
Patient problems: Cardiac Enzyme Elevation; Dyspnea; Fatigue; Heart Failure/Congestive Heart Failure; High Blood Pressure/ Hypertension; Mitral Valve Insufficiency/ Regurgitation; Myocardial Hypertrophy; Tricuspid Valve Insufficiency/ Regurgitation
MAUDE report 18293173 ↗InjuryNov 8, 2023Patient Device Interaction Problem; Intravalvular regurgitation; Patient Device Interaction Problem; Intravalvular regurgitation
ADDITIONAL INFORMATION WAS RECEIVED THAT THE PATIENT DEVELOPED SEVERE CENTRAL AORTIC REGURGITATION, AND THE PATIENT WAS SUBSEQUENTLY PLACED ON A VENTILATOR. IT WAS NOTED THAT THE ONSET WAS ABRUPT. THE PATIENT WENT FROM NO REGURGITATION TO SEVERE REGURGITATION. NO INTERVENTION WAS PERFORMED, AND THE PATIENT WAS PLACED IN HOSPICE CARE. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Heart Failure/Congestive Heart Failure
MAUDE report 18092011 ↗MalfunctionOct 17, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT EIGHT YEARS AND ONE MONTH FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, THE PATIENT IS BEING EVALUATED FOR A TRANSCATHETER AORTIC VALVE (TAV)-IN-TAV PROCEDURE. THE REASON FOR REPLACEMENT WAS NOT REPORTED. NO ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 17953065 ↗InjuryOct 10, 2023Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem; Adverse Event Without Identified Device or Use Problem; Patient Device Interaction Problem
MEDTRONIC RECEIVED INFORMATION THAT FOUR DAYS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED DUE TO AN UNSPECIFIED/INCOMPLETE ATRIO-VENTRICULAR BLOCK. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Non specific EKG/ECG Changes
MAUDE report 17904041 ↗InjuryJul 19, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
MEDTRONIC RECEIVED INFORMATION THAT EIGHT YEARS AND SIX MONTHS POST IMPLANT OF THIS AORTIC BIOPROSTHETIC VALVE, THE PATIENT WAS EVALUATED FOR A TRANSCATHETER VALVE REPLACEMENT. THE REASON FOR EVALUATION WAS DUE TO AN UNSPECIFIED VALVE FAILURE. A NON-MEDTRONIC VALVE WAS SUBSEQUENTLY IMPLANTED VALVE IN VALVE. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Insufficient Information
MAUDE report 17350515 ↗InjuryApr 12, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
MEDTRONIC RECEIVED INFORMATION THAT FIVE DAYS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED DUE TO COMPLETE HEART BLOCK. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Heart Block
MAUDE report 16724418 ↗InjurySep 8, 2022Degraded; Degraded
MEDTRONIC RECEIVED INFORMATION THAT 5 YEARS 11 MONTHS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, THE PATIENT WAS IMAGED FOR SEVERE STENOSIS. THE VALVE WAS REPLACED, VALVE IN VALVE WITH A 31 MM NON-MEDTRONIC TRANSCATHETER VALVE. NO ADDITIONAL ADVERSE PATIENT EFFECTS WERE REPORTED.
Patient problems: Aortic Valve Stenosis
MAUDE report 15383951 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P130021. One submission often covers many models, so check the product and lot details in each record.
- Z-0560-2021 · Oct 23, 2020 · TerminatedEvolut (TM) PRO System. With the following model numbers: a. EVOLUTPRO-23, Labeled as: VLV EVOLUTPRO-23 PRO COMM 29L OUS, VLV EVOLUTPRO-23 BLUE 29L COMM OUS, VLV EVOLUTPRO-23 B
- Z-0561-2021 · Oct 23, 2020 · TerminatedEvolut (TM) PRO+ System. With the following model numbers: a. EVPROPLUS-23US, Labeled as VLV EVPROPLUS-23US COMM JPN, VLV EVPROPLUS-23 COMM US; b. EVPROPLUS-26US, Labeled as
- Z-0559-2021 · Oct 23, 2020 · TerminatedEvolut (TM) R System. With the following model numbers: a. EVOLUTR-23, Labeled as VLV EVOLUTR-23 VT IR 6L COMM OUS, VLV EVOLUTR-23 TAV EVOLUT R CE 29L MX, VLV EVOLUTR-23 TAV CE
- Z-2264-2015 · Jul 15, 2015 · TerminatedEnVeo R Loading System, Model No. LS-EnVeoR-23, LS-EnVeoR-2629, LS-EnVeoR-23-C, LS-EnVeoR-2629-C. Cardiovascular valve delivery system for use with the Medtronic CoreValve Evol
Other Aortic valve, prosthesis, percutaneously delivered devices
- Evolut™ PRO+ EVPROPLUS-29USMedtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered57 deaths869 reports
- Evolut™ PRO+ EVPROPLUS-34USMedtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered43 deaths613 reports
- CoreValve™ Evolut™ PRO EVOLUTPRO-29-USMedtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered30 deaths596 reports
- Evolut™ PRO+ EVPROPLUS-26USMedtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered66 deaths578 reports
- Evolut™ FX EVOLUTFX-29Medtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered47 deaths564 reports
- Evolut™ FX EVOLUTFX-34Medtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered22 deaths563 reports
- Evolut™ FX D-EVOLUTFX-2329Medtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered79 deaths555 reports
- Navitor™ NVRO-27St. Jude Medical, Inc. · Aortic valve, prosthesis, percutaneously delivered1 recall35 deaths471 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page