NA 42314Recalls & reported problems
Medtronic Ps Medical, Inc. · VALVE 42314 SM CONTOURED MED PRESS IMP · Class 2 · Implant
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00643169466487), received between Jan 6, 2017 and Jun 13, 2019 — classified as 2 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Device Operates Differently Than Expected” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K841442); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Device Operates Differently Than Expected1
- Inaccurate Flow Rate1
Patient problems
- No Known Impact Or Consequence To Patient2
- Abdominal Pain1
- Bacterial Infection1
- Unspecified Infection1
- Vomiting1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
InjuryJun 13, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON (B)(6) 2017, THE PATIENT PRESENTED WITH VOMITING AND ABDOMINAL PAIN AND WITHOUT HEADACHES OR CHANGE IN MENTAL STATUS. THEY WERE FOUND TO HAVE A SMALL-BOWEL OBSTRUCTION AND WAS BROUGHT TO THE OPERATING ROOM TO DETERMINE THE CAUSE OF THE BOWEL OBSTRUCTION AND TO RULE OUT SHUNT INFECTION. THE PATIENT HAD A LAPAROTOMY WHERE 2 PIECES OF THE VENTRICULOPERITONEAL (VP) SHUNT TUBING WERE EXTERIORIZED. ONE WAS DRIPPING CEREBROSPINAL FLUID, AND THE OTHER WAS WITH NO EVIDENCE OF ANY DRAINAGE. THE DOCTOR OBTAINED A STAT CEREBROSPINAL GRAM STAIN AND CULTURE TO EVALUATE FOR INFECTION. THE CEREBROSPINAL FLUID SENT FROM THE OPERATION REVEALED NO EVIDENCE OF INFECTION, WITH A NEGATIVE GRAM STAIN AND CLEAN PROFILE; HOWEVER, ON THE MORNING OF (B)(6) 2017, THE CEREBROSPINAL FLUID FROM THAT SURGERY BEGAN GROWING STAPHYLOCOCCUS. THE PATIENT'S LEFT PARIETAL VP SHUNT WAS REMOVED AND REPLACED WITH A LEFT PARIETAL EXTERNAL VENTRICULAR DRAIN. THEY ALSO UNDERWENT IV ANTIBIOTIC THERAPY AFTER THE PICC LINE WAS PLACED AS WELL AS REQUIRED A PLATELET TRANSFUSION PRIOR TO THE PROCEDURE.
Patient problems: Abdominal Pain; Bacterial Infection; Vomiting
MAUDE report 8697898 ↗InjuryJun 12, 2018Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT EXPERIENCED AN INFECTION POTENTIALLY FROM THE SHUNT. THE DEVICE WAS EXPLANTED AND REPLACED. THE PATIENT'S CURRENT STATUS WAS ALIVE-NO INJURY.
Patient problems: Unspecified Infection
MAUDE report 7593159 ↗MalfunctionAug 24, 2017Device Operates Differently Than Expected; Device Operates Differently Than Expected
IT WAS REPORTED TO MEDTRONIC NEUROSURGERY THAT THE DEVICE DIDN'T WORK.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6818008 ↗MalfunctionJan 6, 2017Inaccurate Flow Rate; Inaccurate Flow Rate
IT WAS REPORTED TO MEDTRONIC NEUROSURGERY THAT THE DEVICE WAS NOT DRAINING PROPERLY INTRA-OPERATIVELY. ACCORDING TO THE REPORT, THE DEVICE WAS SUCCESSFULLY REPLACED DURING THE PROCEDURE. REPORTEDLY, THERE WAS NO PATIENT INJURY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6229376 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K841442. One submission often covers many models, so check the product and lot details in each record.
- Z-1117-2021 · Jan 11, 2021 · Open, ClassifiedMedtronic PS Medical Cerebro Spinal Fluid (CSF)-Flow Control Valves for the following CFNs: 22011 L- SHUNT 22011 L INTL ONLY ULTRA SM LOW 22011 LL - SHUNT 22011 LL INTL ONLY
- Z-0397-2014 · Nov 18, 2013 · TerminatedCSF-Unitized Shunt, Contoured Regular, Low Pressure, Catalog No. 46022; CSF-Unitized Shunt, Contoured Regular, Medium Pressure, Catalog No. 46024; CSF-Unitized Shunt, Contoured Reg
Other Shunt, central nervous system and components devices
- NATUS EDS3 DRAINAGE SYSTEM NT821731CNatus Medical Incorporated · Shunt, Central Nervous System And Components1 recall208 reports
- Exacta™ 46700Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall2 deaths163 reports
- Strata® 42866Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 death160 reports
- proGAV 2.0® FX410TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components119 reports
- PROGAV 2.0 FX643TAesculap AG · Shunt, central nervous system and components100 reports
- Becker® 46128Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall50 reports
- M.BLUE PLUS FX804TAesculap AG · Shunt, central nervous system and components82 reports
- proSA® FV701TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components82 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.