NA 42312Recalls & reported problems
Medtronic Ps Medical, Inc. · VALVE 42312 SM CONTOURED LOW PRES IMP · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00643169466494), received between Mar 10, 2017 and May 23, 2019 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K841442); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem2
- Break1
Patient problems
- Erosion1
- Fluid Discharge1
- No Known Impact Or Consequence To Patient1
- Wound Dehiscence1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryMay 23, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON (B)(6) 2017, THE PATIENT WAS ADMITTED TO THE HOSPITAL FOR A WOUND LEAK AT THE SURGICAL SITE. THE DOCTOR REPAIRED THE SURGICAL INCISION. IT WAS NOTED THE WOUND WAS OVERSEWN WITH 3-0 MONOCRYL AT THE PATIENT'S BEDSIDE AFTER LOCAL INJECTION. IT WAS ALSO STATED THAT THERE WAS A SLIGHT WORSENING OF HYDROCEPHALUS; HOWEVER, THERE WAS NO EVIDENCE OF SHUNT MALFUNCTION. THE PATIENT WAS RELEASED THE FOLLOWING DAY, AND THE PARENTS WERE INSTRUCTED TO A PUMP REGIMEN OF 10 TIMES EVERY 2 HOURS.
Patient problems: Fluid Discharge
MAUDE report 8636152 ↗InjuryMay 22, 2019Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT DURING THE PATIENT'S MAY ADMISSION FOR CHEMOTHERAPY, THEIR SHUNT TUBING WAS VISIBLE, AND THERE WAS WOUND DEHISCENCE. ON (B)(6) 2017, THE PATIENT'S DOCTORS ATTEMPTED TO SUTURE IT BY CLOSING THE WOUND WITH NYLON SUTURE, BACITRACIN, AND ANTIBIOTICS WERE GIVEN. DUE TO WOUND HEALING PROBLEMS AND INFECTION AS A RESULT OF THE IMMUNOCOMPROMISED STATE OF AN INFANT ON CHEMOTHERAPY, THAT PROVED UNSUCCESSFUL. ON (B)(6) 2017, THE PATIENT WAS ADMITTED TO REVISE THEIR SHUNT DUE TO FURTHER SHUNT COMPLICATIONS. THE SHUNT WAS TAPPED AT THE PATIENT'S BEDSIDE. ON (B)(6), THE DOCTOR REMOVED THEIR SHUNT, DEBRIDED THEIR SCALP TISSUE, AND PLACED AN EXTERNAL VENTRICULAR DRAIN (EVD). ON (B)(6) 2017, THE DOCTOR PLACED A NEW SHUNT AT ANOTHER LOCATION ON THE OTHER SIDE OF THE PATIENT'S HEAD.
Patient problems: Erosion; Wound Dehiscence
MAUDE report 8634039 ↗MalfunctionMar 10, 2017Break; Break
IT WAS REPORTED TO MEDTRONIC NEUROSURGERY THAT THERE WAS A FISSURE ON THE RESERVOIR INTRA-OPERATIVELY. REPORTEDLY, THERE WAS NO INJURY TO THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6395765 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K841442. One submission often covers many models, so check the product and lot details in each record.
- Z-1117-2021 · Jan 11, 2021 · Open, ClassifiedMedtronic PS Medical Cerebro Spinal Fluid (CSF)-Flow Control Valves for the following CFNs: 22011 L- SHUNT 22011 L INTL ONLY ULTRA SM LOW 22011 LL - SHUNT 22011 LL INTL ONLY
- Z-0397-2014 · Nov 18, 2013 · TerminatedCSF-Unitized Shunt, Contoured Regular, Low Pressure, Catalog No. 46022; CSF-Unitized Shunt, Contoured Regular, Medium Pressure, Catalog No. 46024; CSF-Unitized Shunt, Contoured Reg
Other Shunt, central nervous system and components devices
- NATUS EDS3 DRAINAGE SYSTEM NT821731CNatus Medical Incorporated · Shunt, Central Nervous System And Components1 recall208 reports
- Exacta™ 46700Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall2 deaths163 reports
- Strata® 42866Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 death160 reports
- proGAV 2.0® FX410TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components119 reports
- Becker® 46128Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall50 reports
- PROGAV 2.0 FX643TAesculap AG · Shunt, central nervous system and components100 reports
- proSA® FV701TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components82 reports
- M.BLUE PLUS FX804TAesculap AG · Shunt, central nervous system and components82 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page