Medtronic Ps Medical, Inc. · CATH 23047 PERIT STD OE W/SLITS 120 · Class 2 · Implant

Adverse event reports
4
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 00643169483545), received between Jan 14, 2019 and Dec 8, 2022 — classified as 2 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Migration” (3 reports).

1 other recall cover devices cleared under the same FDA submission (K792005); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Most reported problems

Device problems

  • Migration3
  • Break2
  • Complete Blockage2
  • Fracture2
  • Insufficient Device Problem Information2
  • Infusion or Flow Problem1

Patient problems

  • Unspecified Infection2
  • Bowel Perforation1
  • Hydrocephalus1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 8, 2022Break; Complete Blockage; Fracture; Insufficient Device Problem Information; Migration; Break; Complete Blockage; Fracture; Insufficient Device Problem Information; Migration

    DEL BIGIO, M.R., SIDHU, R.K., KAZINA, C.J., SERLETIS, D. INFLAMMATION AND OBSTRUCTION OF DISTAL CATHETER SLITS IN VENTRICULOPERITONEAL SHUNTS: LIKELY ROLE OF GRAPHITE. J NEUROSURG. 2020. 133 (1495¿1502) DOI: 10.3171/2019.6.JNS191082 OBJECTIVE TISSUE REACTIONS THAT CONTRIBUTE TO OBSTRUCTION OF PERITONEAL CATHETERS IN VENTRICULOPERITONEAL SHUNT SYSTEMS ARE NOT WELL CHARACTERIZED. SEVERAL RECENT RAPID OBSTRUCTIONS IN CHILDREN PROMPTED A RETROSPECTIVE QUALITY ASSURANCE REVIEW. METHODS THE AUTHORS CONDUCTED A DETAILED INVESTIGATION OF 22 SURGICALLY EXPLANTED PERITONEAL SHUNT CATHETERS AND 8 AUTOPSY CASES WITH DOCUMENTED DISTAL SHUNT OBSTRUCTION. PATIENTS¿ MEDICAL HISTORIES WERE REVIEWED, AND THE CATHETERS AND/OR TISSUES WERE SUBJECTED TO CONVENTIONAL HISTOLOGICAL AND IMMUNOHISTOCHEMICAL EVALUATIONS. IN ADDITION, 3 CASES WERE SUBJECTED TO ELECTRON MICROSCOPIC EXAMINATION INCLUDING ELEMENTAL ANALYSIS. RESULTS THE MAJORITY OF SYMPTOMATIC OBSTRUCTIONS WERE ASSOCIATED WITH DISTAL SLIT CATHETERS (17 SLIT, 3 OPEN-END, AND 2 UNKNOWN TYPE). AMONG THE AUTOPSY CASES, DEATHS WERE ATTRIBUTED TO SHUNT FAILURE IN 2 CASES OF SLIT CATHETER OBSTRUCTION, 1 CASE OF OPEN-END CATHETER OBSTRUCTION, AND 1 CASE

    Patient problems: Unspecified Infection

    MAUDE report 15945024 ↗
  • MalfunctionDec 8, 2022Break; Complete Blockage; Fracture; Insufficient Device Problem Information; Migration; Break; Complete Blockage; Fracture; Insufficient Device Problem Information; Migration

    DEL BIGIO, M.R., SIDHU, R.K., KAZINA, C.J., SERLETIS, D. INFLAMMATION AND OBSTRUCTION OF DISTAL CATHETER SLITS IN VENTRICULOPERITONEAL SHUNTS: LIKELY ROLE OF GRAPHITE. J NEUROSURG. 2020. 133 (1495¿1502) DOI: 10.3171/2019.6.JNS191082 OBJECTIVE TISSUE REACTIONS THAT CONTRIBUTE TO OBSTRUCTION OF PERITONEAL CATHETERS IN VENTRICULOPERITONEAL SHUNT SYSTEMS ARE NOT WELL CHARACTERIZED. SEVERAL RECENT RAPID OBSTRUCTIONS IN CHILDREN PROMPTED A RETROSPECTIVE QUALITY ASSURANCE REVIEW. METHODS THE AUTHORS CONDUCTED A DETAILED INVESTIGATION OF 22 SURGICALLY EXPLANTED PERITONEAL SHUNT CATHETERS AND 8 AUTOPSY CASES WITH DOCUMENTED DISTAL SHUNT OBSTRUCTION. PATIENTS¿ MEDICAL HISTORIES WERE REVIEWED, AND THE CATHETERS AND/OR TISSUES WERE SUBJECTED TO CONVENTIONAL HISTOLOGICAL AND IMMUNOHISTOCHEMICAL EVALUATIONS. IN ADDITION, 3 CASES WERE SUBJECTED TO ELECTRON MICROSCOPIC EXAMINATION INCLUDING ELEMENTAL ANALYSIS. RESULTS THE MAJORITY OF SYMPTOMATIC OBSTRUCTIONS WERE ASSOCIATED WITH DISTAL SLIT CATHETERS (17 SLIT, 3 OPEN-END, AND 2 UNKNOWN TYPE). AMONG THE AUTOPSY CASES, DEATHS WERE ATTRIBUTED TO SHUNT FAILURE IN 2 CASES OF SLIT CATHETER OBSTRUCTION, 1 CASE OF OPEN-END CATHETER OBSTRUCTION, AND 1 CASE

    Patient problems: Unspecified Infection

    MAUDE report 15944515 ↗
  • InjuryDec 18, 2020Infusion or Flow Problem; Infusion or Flow Problem

    ADDITIONAL INFORMATION RECEIVED REPORTED THAT THERE WERE NO ENVIRONMENTAL/EXTERNAL/PATIENT FACTORS THAT MAY HAVE LED OR CONTRIBUTED TO THE ISSUE.

    Patient problems: Hydrocephalus

    MAUDE report 11037261 ↗
  • InjuryJan 14, 2019Migration; Migration

    IT WAS REPORTED THAT DURING A FOLLOW UP APPOINTMENT FOR A PATIENT WITH POST-HEMORRHAGIC ASYMMETRICAL HYDROCEPHALUS, THE DOCTOR REALIZED THAT THE PERITONEAL CATHETER HAD EXITED THROUGH THE ANUS OF THE PATIENT. IT WAS STATED THE CATHETER HAD PERFORATED THE INTESTINE. THE PATIENT WAS WELL HOWEVER. THE CATHETER WAS EXPLANTED AND THE PATIENT WAS CONNECTED TO AN EXTERNAL DRAINAGE SYSTEM WHILE LIQUID ANTIBIOTICS WERE ADMINISTERED. WHILE THE PATIENT WAS CONNECTED TO THE EXTERNAL DRAINAGE SYSTEM, THEY COULD NOT STAND UP SINCE THE VALVE DID NOT PREVENT OVERDRAINAGE. THE VALVE WAS ALSO REPLACED. THE PATIENT¿S STATUS WAS NOTED AS ALIVE; NO INJURY.

    Patient problems: Bowel Perforation

    MAUDE report 8243398 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K792005. One submission often covers many models, so check the product and lot details in each record.

  • Z-0397-2014 · Nov 18, 2013 · Terminated
    CSF-Unitized Shunt, Contoured Regular, Low Pressure, Catalog No. 46022; CSF-Unitized Shunt, Contoured Regular, Medium Pressure, Catalog No. 46024; CSF-Unitized Shunt, Contoured Reg

Other Shunt, central nervous system and components devices

All Shunt, central nervous system and components devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.