CD HORIZON® SOLERA® Spinal System 641100040Recalls & reported problems
Medtronic Sofamor Danek, Inc. · ROD 641100040 40MM PERC ROD 4.75 CCM ST · Class 2 · Implant
All models of CD HORIZON SOLERA Spinal System (34)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169501447), received between Apr 15, 2019 and Apr 15, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Migration1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 15, 2019Migration; Migration
PRE-OPERATIVE DIAGNOSIS- LUMBAR FORAMINAL STENOSIS WITH DISC DISORDER PROCEDURE- POSTERIOR LUMBAR INTERBODY FUSION(PLIF) LEVELS IMPLANTED- L5/S IT WAS REPORTED THAT THE ROD WAS INSERTED WITH PERCUTANEOUS PEDICLE SCREW TECHNIQUE, BUT THE POSTOPERATIVE X-RAY IMAGE SHOWED THAT THE ROD WHICH WAS ON THE RIGHT CRANIAL SIDE CAME OFF FROM THE SCREW AND REVISION SURGERY WAS PERFORMED IMMEDIATELY. THERE WAS A DELAY OF LESS THAN A 60 MINUTES AS A RESULT OF THIS EVENT. NO PATIENT COMPLICATIONS WERE REPORTED DURING THIS EVENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8513541 ↗
Other Pedicle screw spinal system, adolescent idiopathic scoliosis devices
- CD HORIZON® Spinal System 5540030Medtronic Sofamor Danek, Inc. · Pedicle screw spinal system, adolescent idiopathic scoliosis230 reports
- CD HORIZON® Spinal System 7578302Medtronic Sofamor Danek, Inc. · Pedicle screw spinal system, adolescent idiopathic scoliosis122 reports
- EXPEDIUM 179762480Medos International Sàrl · Pedicle screw spinal system, adolescent idiopathic scoliosis114 reports
- ReLine 13550000Nuvasive, Inc. · Pedicle screw spinal system, adolescent idiopathic scoliosis55 reports
- CD HORIZON® Spinal System 5440030Medtronic Sofamor Danek, Inc. · Pedicle screw spinal system, adolescent idiopathic scoliosis50 reports
- EXPEDIUM 179712640Medos International Sàrl · Pedicle screw spinal system, adolescent idiopathic scoliosis28 reports
- EXPEDIUM 179788635Medos International Sàrl · Pedicle screw spinal system, adolescent idiopathic scoliosis18 reports
- EXPEDIUM VIPER 196789300Depuy Spine, LLC · Pedicle screw spinal system, adolescent idiopathic scoliosis18 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page