NIM® 8253402Recalls & reported problems

Medtronic Xomed, Inc. · MAINFRAME 8253402 NEURO 3.0 INTL EL ROHS · Class 2

Quick summary

This is a Medtronic Xomed NIM 3.0 nerve stimulator mainframe, the console used during surgery to check that nerves still respond to electrical stimulation. The 31 reports mostly describe the unit not powering up, not responding to stimulation, or one channel dropping out during pre-op checks, along with inaccurate or false readings and occasional software freezes. No deaths or injuries were reported, and most events happened before or during surgery with no patient harm described. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
31
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 31 adverse event reports that list this exact device (DI 00643169547087), received between May 16, 2025 and Sep 11, 2026 — classified as 31 malfunctions.

The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (19 reports).

3 other recalls cover devices cleared under the same FDA submission (K083124); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 3 reportsJul 2025: 3 reportsAug 2025: 3 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 4 reportsJan 2026: 4 reportsFeb 2026: 1 reportsMar 2026: 2 reportsApr 2026: 3 reportsMay 2026: 4 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 1 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Incorrect, Inadequate or Imprecise Result or Readings19
  • False Negative Result7
  • Failure to Power Up3
  • Inappropriate Audible Prompt/Feedback3
  • Application Program Freezes or Fails to Launch2
  • Break1
  • Computer Software Problem1
  • Signal Artifact/Noise1

Patient problems

  • No Clinical Signs, Symptoms or Conditions30
  • Insufficient Information1

Recent adverse event reports

The 25 most recent of 31 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 11, 2026Incorrect, Inadequate or Imprecise Result or Readings

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50726075 ↗
  • MalfunctionAug 16, 2026Incorrect, Inadequate or Imprecise Result or Readings

    It was reported that intra-op, the NIM 3.0 device was not working - any signal from stimulation; not even negative; they tried to use a lot of different probes. There was no patient impact.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50266288 ↗
  • MalfunctionJun 24, 2026Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT PRIOR TO USE, MAINFRAME WAS NOT WORKING PROPERLY. THERE WAS NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25605738 ↗
  • MalfunctionMay 26, 2026Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT PRE-OP, THE MAINFRAME WAS NOT WORKING PROPERLY. THERE IS NO PATIENT INVOLVED IN THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25274727 ↗
  • MalfunctionMay 25, 2026False Negative Result; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT DURING PRE-OP, THE NIM HAD NO STIM RESPONSE. SOMETIMES THE CHANNEL FUNCTION DOESN'T WORK PROPERLY AND THERE IS NO RESPONSE TO STIMULATION. ONE CHANNEL'S STIMULATION FEEDBACK IS 0, WHILE THE OTHERS ARE NORMAL. CHANNEL 1 HAS NO WAVEFORM AND NO STIMULATION FEEDBACK SOUND. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25273445 ↗
  • MalfunctionMay 19, 2026False Negative Result

    IT WAS REPORTED THAT PRE-OP, THERE WAS NO STIMULATION RESPONSE. PROCEDURE WAS COMPLETED USING OTHER EQUIPMENT. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25212443 ↗
  • MalfunctionMay 7, 2026Use of Device Problem

    IT WAS REPORTED THAT DURING PRE-OP, THE MAINFRAME WAS NOT WORKING. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25108387 ↗
  • MalfunctionApr 29, 2026Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT PRE-OP, THE MAINFRAME WAS NOT WORKING PROPERLY. THERE IS NO PATIENT INVOLVED IN THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25030402 ↗
  • MalfunctionApr 13, 2026Signal Artifact/Noise; Inappropriate Audible Prompt/Feedback

    IT WAS REPORTED THAT DURING INTRA-OP, THE NIM 3.0 HAD INTERFERENCE LEVELS EXCESSIVELY HIGH, TO THE POINT THAT STIMULUS DETECTION WAS NOT POSSIBLE. THE SIGNAL WAS COMPARABLE TO A MONOPOLAR ELECTRODE WITHOUT A SILENCER, PRESENTING CONSTANT HIGH-AMPLITUDE OSCILLATIONS AND A CONTINUOUSLY REPETITIVE PATTERN, ALONG WITH A PERSISTENT STIMULATION ALERT TONE. THIS CONDITION REMAINED CONSTANT THROUGHOUT THE ENTIRE PROCEDURE. THERE WAS NO KNOWN PATIENT IMPACT.

    Patient problems: Insufficient Information

    MAUDE report 24854680 ↗
  • MalfunctionApr 10, 2026Incorrect, Inadequate or Imprecise Result or Readings; Inappropriate Audible Prompt/Feedback

    IT WAS REPORTED THAT DURING USE, NIM CONSOLE HAD INTERMITTENT SYSTEM FAILURES STARTUP ERRORS, EXCESSIVE INTERFERENCE, AND DISABLED EMG MONITORING DESPITE CONSISTENTLY PASSING ALL TESTS AND CHECKS. DURING THE PROCEDURE, IT WAS NOT POSSIBLE TO DETECT ANY TYPE OF SIGNAL, NEITHER NEURAL ACTIVITY NOR INTERFERENCE, INCLUDING NO SIGNAL FROM THE UNSILENCED ELECTRODE. A FULL SYSTEM CHECK WAS PERFORMED MULTIPLE TIMES, INCLUDING REPEATED TEST FUNCTION VERIFICATION, CONSISTENTLY CONFIRMING PROPER SYSTEM PERFORMANCE. CONNECTIONS, CONFIGURATIONS, AND OTHER PARAMETERS WERE REVIEWED WITHOUT SUCCESS. DURING THE FINAL 15 MINUTES OF THE PROCEDURE, THE PHYSICIAN DECIDED TO USE A PERSONAL PORTABLE DEVICE. UPON STIMULATION WITH THAT DEVICE, A SIGNAL WAS DETECTED ON OUR SYSTEM (WITHOUT ANY CHANGES MADE SINCE THE LAST TEST, DURING WHICH NO SIGNALS HAD BEEN DETECTED). AT THAT POINT, I SUGGESTED THAT THE PHYSICIAN ATTEMPT NERVE STIMULATION AGAIN, RESULTING IN A POSITIVE RESPONSE, ALTHOUGH WITH LOW AMPLITUDE (100 V). THIS EVENT WAS RECORDED AND SUBSEQUENTLY SAVED TO A USB DRIVE. THE SYSTEM HAD PASSED THE TEST FUNCTION SUCCESSFULLY. FOLLOWING THE ISSUE, STANDARD TROUBLESHOOTING STEPS WERE PERFORMED, INCLUDING

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24842395 ↗
  • MalfunctionMar 30, 2026Application Program Freezes or Fails to Launch

    IT WAS REPORTED THAT AFTER THE OPERATION, THE NIM SYSTEM CRASHED EVERY TIME. THE PROTOCOL WAS SAVED TO A USB STICK. NO LOG COULD BE SAVED. SINCE THERE WAS NO INTERNAL MEMORY ON THE DEVICE, THE DATA COULD NO LONGER BE SAVED EITHER.THE ISSUE WAS NOT RESOLVED BY TROUBLESHOOTING. THERE WAS NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24725700 ↗
  • MalfunctionMar 9, 2026Incorrect, Inadequate or Imprecise Result or Readings

    ADDITIONAL INFORMATION RECEIVED STATING THAT THE DEVICE WAS UNABLE TO START/OPERATE NORMALLY, WHICH LED TO INTERRUPTION IN INTENDED USAGE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24542619 ↗
  • MalfunctionFeb 8, 2026Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED DURING SETUP THE DEVICE WAS NOT WORKING. THERE WAS NO PATIENT INVOLVED IN THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24288689 ↗
  • MalfunctionJan 30, 2026Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT DURING PRE-OP, THE MAINFRAME HAD NO STIMULATION RESPONSE. THE STIMULUS RETURN DISPLAYED AS "0," AND ¿STIMULUS DELIVERY¿ TONE WAS NOT HEARD WHEN ATTEMPTING TO STIMULATE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24220802 ↗
  • MalfunctionJan 26, 2026Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT DURING POST-OP, THE NIM MAINFRAME WAS NOT WORKING. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24186162 ↗
  • MalfunctionJan 26, 2026Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT THE MAINFRAME WAS NOT WORKING. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24186059 ↗
  • MalfunctionJan 2, 2026Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT PRIOR TO USE, THE DEVICE WAS NOT WORKING. THERE WAS NO PATIENT INVOLVED IN THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23941246 ↗
  • MalfunctionDec 30, 2025Inappropriate Audible Prompt/Feedback; Inappropriate Audible Prompt/Feedback

    IT WAS REPORTED THAT PRE-OP, THE DEVICE HAD A LOT OF INTERFERENCE. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23920290 ↗
  • MalfunctionDec 22, 2025False Negative Result; False Negative Result

    IT WAS REPORTED THAT PRIOR TO USE, NIM EQUIPMENT IS UNDER BREAKDOWN AND IS NOT DETECTING SIGNALS. THERE IS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23862286 ↗
  • MalfunctionDec 22, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    EVENT OCCURRED DURING INTRA-OP THAT THE DEVICE IS NOT ACCURATE AND INDICATED IT WAS NERVE WITH OTHER TISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23861992 ↗
  • MalfunctionDec 2, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT PRIOR TO PROCEDURE THE NIM 3.0 MAINFRAME WAS NOT WORKING. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23690866 ↗
  • MalfunctionAug 28, 2025False Negative Result; False Negative Result

    IT WAS REPORTED THAT PRE OP, DEVICE HAD NO SOUND. THERE IS NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22911249 ↗
  • MalfunctionAug 19, 2025Break; False Negative Result; Incorrect, Inadequate or Imprecise Result or Readings; Break; False Negative Result; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT DURING DEMO OR INSTALLATION, WHEN USER STIMULATE, NIM 3.0 EQUIPMENT DON¿T RECOGNIZE THE SIGNAL. ALSO, DON¿T MUTE THE ELECTRONIC INTERFERENCES. THE MUTE CONNECTOR IS BROKEN OR LOOSE. WHEN THEY USE PATIENT SIMULATOR AND HAVE THE SAME RESPONSE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22838088 ↗
  • MalfunctionAug 6, 2025Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings

    IT WAS REPORTED THAT THE MAINFRAME WAS SLOW TO OPERATE DURING IGNITION AND ALSO CHECKED THE PATIENT INTERFACE WHERE THE ELECTRODES ARE INSERTED AS PROBLEMS HAVE OCCURRED IN THE RETURN OF THE GROUNDING. DESPITE THE FORKLIFT REMOTE CONTROL, THE MACHINE IS ALWAYS SLOW AND HAS TURNED OFF DURING THE INTERVENTION. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22734787 ↗
  • MalfunctionJul 30, 2025Computer Software Problem; Failure to Power Up; Computer Software Problem; Failure to Power Up

    IT WAS REPORTED THAT PRIOR TO PROCEDURE THE NIM 3.0 MAINFRAME DID NOT TURN ON. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22666593 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K083124. One submission often covers many models, so check the product and lot details in each record.

  • Z-2344-2012 · Sep 27, 2010 · Terminated
    Interfaces subject to recall: Medtronic NIM (Nerve Integrity Monitor) 3.0 Patient Interfaces REF 8253210 (Pulse). LABELING: Box Label: REF 8253210 x1***NIM-Response 3.0 Patie
  • Z-2343-2012 · Sep 27, 2010 · Terminated
    Interfaces subject to recall: Medtronic NIM (Nerve Integrity Monitor) 3.0 Patient Interfaces REF 8253410 (Neuro). LABELING: Box Label: REF 8253410 x1***NIM-Response 3.0 Patie
  • Z-2342-2012 · Sep 27, 2010 · Terminated
    Interfaces subject to recall: Medtronic NIM (Nerve Integrity Monitor) 3.0 Patient Interfaces 8253200 (Response) LABELING: Box Label: REF 8253200 x1***NIM-Response 3.0 Patient

Other STIMULATOR, NERVE devices

All STIMULATOR, NERVE devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.