CD HORIZON® Spinal System X0212549Recalls & reported problems
Medtronic Sofamor Danek, Inc. · SCR X0212549 SOL 5.5-6.0 UAS CC 6.5X40 · Class 2 · Implant
All models of CD HORIZON Spinal System (342)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00643169607095), received between May 30, 2022 and May 30, 2022 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Mechanical Jam” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Mechanical Jam2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 30, 2022Mechanical Jam; Mechanical Jam
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH PRE-OPERATIVE DIAGNOSIS FOR SPINAL STENOSIS. PROCEDURE OR TECHNIQUE USED WAS OPEN PLF. LEVELS IMPLANTED L3-5. IT WAS REPORTED THAT AFTER IMPLANTING THE SCREWS, SURGEON TRIED TO SEAT THE RODS. TWO HEADS OF THE SCREWS WERE NOT ROTATING. AFTER BACKING THE SCREWS OUT SLIGHTLY (ABOUT A HALF TO A FULL TURN) TO GET THE POLYAXIAL HEAD TO LOOSEN SO IT COULD ROTATE ENOUGH TO SEAT THE ROD. HOWEVER AFTER DOING THAT WITH EACH SCREW, THE TWO SCREW HEADS WERE STILL ONLY MOVING CEPHALAD/ CAUDAL. SO SURGEON REMOVED EACH SCREW AND RE-IMPLANTED WITH TWO LONGER SCREWS (6.5X45). THERE WERE NO SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. THE SCREW WOULDN¿T MOVE MEDIAL/LATERAL BUT OTHER THAN THAT NO REAL ISSUE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14539297 ↗MalfunctionMay 30, 2022Mechanical Jam; Mechanical Jam
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT WITH PRE-OPERATIVE DIAGNOSIS FOR SPINAL STENOSIS. PROCEDURE OR TECHNIQUE USED WAS OPEN PLF. LEVELS IMPLANTED L3-5. IT WAS REPORTED THAT AFTER IMPLANTING THE SCREWS, SURGEON TRIED TO SEAT THE RODS. TWO HEADS OF THE SCREWS WERE NOT ROTATING. AFTER BACKING THE SCREWS OUT SLIGHTLY (ABOUT A HALF TO A FULL TURN) TO GET THE POLYAXIAL HEAD TO LOOSEN SO IT COULD ROTATE ENOUGH TO SEAT THE ROD. HOWEVER AFTER DOING THAT WITH EACH SCREW, THE TWO SCREW HEADS WERE STILL ONLY MOVING CEPHALAD/ CAUDAL. SO SURGEON REMOVED EACH SCREW AND RE-IMPLANTED WITH TWO LONGER SCREWS (6.5X45). THERE WERE NO SYMPTOMS REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. THE SCREW WOULDN¿T MOVE MEDIAL/LATERAL BUT OTHER THAN THAT NO REAL ISSUE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14539295 ↗
Other APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- XLP 7565050Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430344Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- ATLANTIS® Anterior Cervical Plate System 876-170Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- XLP 7565060Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430113Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page