T2 STRATOSPHERE™ Expandable Corpectomy System 4360308Recalls & reported problems

Medtronic Sofamor Danek, Inc. · ENDCAP 4360308 30MM 8 DEGREE · Class 2 · Implant

All models of T2 STRATOSPHERE Expandable Corpectomy System (52)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169651029), received between Jul 18, 2022 and Jul 18, 2022 — classified as 1 injury.

The most frequently reported specific device problem is “Migration” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Migration1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 18, 2022Migration; Migration

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING L5 CORPECTOMY F ROM AN ANTERIOR APPROACH. IT WAS REPORTED THAT STRATOSPHERE CAGE WAS PLACED WITH A PYRAMID 3 HOLE PLATE PLACED AT THE PROMONTORY OF S1. AFTER THIS STAGE PATIENT WAS FLIPPED TO PRONE AND A L2-IL PROCEDURE WAS PERFORMED USING SOLERA MAS SCREWS AND BALLAST CMAS SCREWS. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT. ADDITIONAL INFORMATION WAS RECEIVED: PRE-OP DIAGNOSIS/MEDICAL HISTORY: L5 BURST FRACTURE PROCEDURE INVOLVED: L5 CORPECTOMY WITH EXPANDABLE CAGE PLACEMENT FROM L4 ENDPLATE TO S1 ENDPLATE. PLATE IMPLANTED ANTERIORLY AT S1. THE EXPOSURE SURGEON IN THE ROOM FOR THE REMOVAL NOTED THE PATIENT ACKNOWLEDGED A FALL AFTER SURGERY (TIMEFRAME UNKNOWN). THE FRONT OF S1 BROKE OFF CAUSING THE PLATE AND 2 SCREWS TO BREAK OFF THE BONE. THE CAGE ALSO KICKED OUT ANTERIORLY AFTER THIS INCIDENT AND AT THIS POINT WAS NOT ADDING ANY STRUCTURAL SUPPORT TO THE CONSTRUCT. THE PATIENT HAD POSTERIOR HARDWARE IN WHICH ALL STAYED INTACT. AFTER THE FRACTURE AT S1 AND THE HARDWARE KICKED OUT ANTERIORLY THE PATIENT WAS NO LONGER STRUCTURALLY SUPPORTED UP FR

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15037666 ↗

FDA clearance and classification

Cleared through 510(k) K173125 on Dec 20, 2017 (decision: Substantially Equivalent). Submitted by Medtronic Sofamor Danek as “T2 STRATOSPHERE™ Expandable Corpectomy System”. The FDA review took 82 days. FDA record ↗

The FDA regulates product code MQP (spinal vertebral body replacement device) under 21 CFR 888.3060 as a Class II device. 21 CFR 888.3060 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the T2 STRATOSPHERE™ Expandable Corpectomy System 4360308

Has the T2 STRATOSPHERE™ Expandable Corpectomy System 4360308 been recalled?

No FDA recall record in our data names this exact device identifier (DI 00643169651029), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the T2 STRATOSPHERE™ Expandable Corpectomy System 4360308?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jul 18, 2022. That report lists device problem “Migration” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the T2 STRATOSPHERE™ Expandable Corpectomy System 4360308?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the T2 STRATOSPHERE™ Expandable Corpectomy System 4360308 FDA approved?

It was cleared through 510(k) K173125 on Dec 20, 2017. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the T2 STRATOSPHERE™ Expandable Corpectomy System 4360308 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the T2 STRATOSPHERE™ Expandable Corpectomy System 4360308, and is it still sold?

The FDA's device database lists Medtronic Sofamor Danek, Inc. as the company responsible for it (brand T2 STRATOSPHERE™ Expandable Corpectomy System, model 4360308). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Spinal vertebral body replacement device devices

All Spinal vertebral body replacement device devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page