T2 STRATOSPHERE™ Expandable Corpectomy System 436020BRecalls & reported problems

Medtronic Sofamor Danek, Inc. · CENTERPIECE 436020B 20MM B-SIZE · Class 2 · Implant

All models of T2 STRATOSPHERE Expandable Corpectomy System (52)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00643169663176), received between Jun 15, 2021 and Dec 14, 2023 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Mechanics Altered” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Mechanics Altered2
  • Mechanical Jam1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 14, 2023Mechanics Altered; Mechanics Altered

    INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PATIENT HAVING SPINAL THERAPY FOR UNKNOWN INDICATION. IT WAS REPORTED THAT CAGE COULD NOT BE OPENED DURING SURGERY.  THERE WAS NO PATIENT SYMPTOM REPORTED. THERE WERE NO FURTHER COMPLICATIONS REPORTED REGARDING THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18324916 ↗
  • MalfunctionJun 15, 2021Mechanical Jam; Mechanics Altered; Mechanical Jam; Mechanics Altered

    INFORMATION WAS RECEIVED FROM A HEALTH CARE PROVIDER VIA A MANUFACTURER REPRESENTATIVE REGARDING A CENTERPIECE AND INSERTER USED FOR SPINAL SURGERY. PRE-OP DIAGNOSIS WAS FRACTURE LWS1. PROCEDURE PERFORMED IN THE EVENT WAS VERTEBRAL BODY REPLACEMENT. IT WAS REPORTED THAT INTRA-OPERATIVELY, THE IMPLANT WAS INSERTED, A CORRECTION TO THE BONE WAS NECESSARY SO THAT THE IMPLANT WAS REMOVED AGAIN, REINSERTION WAS NO LONGER POSSIBLE BECAUSE THE IMPLANT COULD NO LONGER BE DISTRACTED AND NO LONGER HELD FIRMLY TO THE INSERTER. DURING FIRST INSERTION, THE INSERTER AND IMPLANT FUNCTIONED WITHOUT ANY PROBLEMS, AND PRELIMINARY DISTRACTION WITH A RING ON THE INSERTER WAS ALSO PROBLEM-FREE. SINCE REWORKING OF THE BONE WAS REQUIRED, THE IMPLANT WAS REMOVED AGAIN. AFTER THAT, IT COULD NO LONGER BE EXTRACTED, AND IT WAS STUCK. IN ADDITION, IT NO LONGER SAT PROPERLY ON THE INSERTER. IT IS UNCLEAR WHETHER THE INSERTER BENT WHEN THE IMPLANT WAS REMOVED AFTER THE FIRST TEMPORARY INSERTION. THE PRODUCTS CAME IN CONTACT WITH PATIENT. THERE WERE NO PATIENT SYMPTOMS OR COMPLICATIONS AS A RESULT OF THIS EVENT. THERE WAS NO TREATMENT OR ADDITIONAL SURGERY PERFORMED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11997489 ↗

Other Spinal vertebral body replacement device devices

All Spinal vertebral body replacement device devices →