CD HORIZON® SOLERA® Spinal System 55720005550Recalls & reported problems
Medtronic Sofamor Danek, Inc. · SCREW 55720005550 5.5/6.0 DRMAS 5.5X50 · Class 2 · Implant
All models of CD HORIZON SOLERA Spinal System (34)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169761612), received between Dec 30, 2025 and Dec 30, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Loosening of Implant Not Related to Bone-Ingrowth” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Loosening of Implant Not Related to Bone-Ingrowth1
Patient problems
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 30, 2025Loosening of Implant Not Related to Bone-Ingrowth; Loosening of Implant Not Related to Bone-Ingrowth
INFORMATION WAS RECEIVED FROM HEALTHCARE PROVIDER (HCP) VIA A MANUFACTURER REPRESENTATIVE REGARDING A PRODUCT USED FOR SPINAL FUSION THERAPY IN A PATIENT WITH CLINICAL ID (B)(6), STUDY NAME AILLIANCE MDT22045CSTAIL. IT WAS REPORTED THAT AT THE 12-MONTH FOLLOW-UP VISIT, IT WAS NOTED THAT THE SUBJECT HAD NOT FULLY FUSED AT ALL TREATED LEVELS AND ALL THE IMPLANTED DEVICES DID NOT APPEAR STABLE AND SECURE. THERE WERE NO FURTHER PATIENT COMPLICATIONS OR SYMPTOMS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT. THERE IS NO ASSESSMENTS MADE BY SPONSOR, INVESTIGATOR AND CEC REGARDING THE RELATEDNESS FOR PRODUCT/THERAPY/PROCEDURE. ADDITIONAL INFORMATION WAS RECEIVED VIA MANUFACTURER REPRESENTATIVE THAT PATIENT IS DOING WELL OVERALL, AND CERTAINLY MUCH BETTER THAN PRE-OP, AND IS QUITE SATISFIED WITH HIS CURRENT STATE. THERE IS NO NEED TO GO THROUGH ANOTHER MAJOR SURGERY, DESPITE THE CT SHOWING PSEUDARTHROSIS (NONUNION) AT THE UPPERMOST FUSION LEVEL L1-2. AS THE L1 SCREWS ARE GROSSLY LOOSENED, THE LIKELIHOOD OF THAT SEGMENT GOING ON TO SOLID UNION IS VERY LOW. AS SUCH, SURGEON DO NOT THINK THAT BONE STIMULATOR IS LIKELY TO BE OF BENEFIT AND EXPLAINED THAT IT IS ESSENTIALLY RIGHT NOW FUNCTIONING
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 23919816 ↗
Other Appliance, fixation, spinal intervertebral body devices
- CD HORIZON® SOLERA® VOYAGER™ Spinal System 6550017Medtronic Sofamor Danek, Inc. · Appliance, fixation, spinal intervertebral body131 reports
- EVEREST® Spinal System 2901-10001VB Spine LLC · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY119 reports
- ZEVO™ Anterior Cervical Plate System 7710015Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall1 report
- XLP 7565050Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430344Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
- ATLANTIS® Anterior Cervical Plate System 876-170Medtronic Sofamor Danek, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- XLP 7565060Nuvasive, Inc. · APPLIANCE, FIXATION, SPINAL INTERVERTEBRAL BODY1 recall0 reports
- Elegance® Anterior Cervical Plate 53430113Clariance · Appliance, Fixation, Spinal Intervertebral Body1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page