ARTiC-L™ 3D Ti Spinal System with TiONIC™ Technology 5330009 (UDI 00643169762077)Recalls & reported problems
Medtronic Sofamor Danek, Inc. · INSERTER 5330009 ARTICULATING INR SHAFT · Class 2
All models of ARTiC-L 3D Ti Spinal System with TiONIC Technology (16)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169762077), received between Mar 23, 2022 and Mar 23, 2022 — classified as 1 injury.
The most frequently reported specific device problem is “Material Deformation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Material Deformation1
- Mechanics Altered1
- Use of Device Problem1
Patient problems
- Paralysis1
- Spinal Cord Injury1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 23, 2022Use of Device Problem; Material Deformation; Mechanics Altered; Use of Device Problem; Material Deformation; Mechanics Altered
INFORMATION WAS RECEIVED FROM A HEALTHCARE PROVIDER VIA A MANUFACTURER REPRESENTATIVE REGARDING AN INSERTER AND CAGE USED FOR SPINAL SURGERY. PRE-OP DIAGNOSIS WAS LUMBAR HERNIA. PROCEDURE PERFORMED IN THE EVENT WAS TLIF. LEVELS IMPLANTED WAS L1/2. IT WAS REPORTED THAT INTRA-OPERATIVELY, WHEN THE ARCTIC-L WAS INSERTED, THE CAGE ROTATED AT THE INTERVERTEBRAL FORAMINA. THERE IS A POSSIBILITY THAT THE DURA INJURY OCCURRED DURING THAT TIME. AFTER THE SURGERY, THE PATIENT SUFFERED FROM PARALYSIS IN THE RIGHT LOWER LIMB. THERE WAS A DELAY OF LESS THAN 60 MINUTES. THE CAGE (8*25 MM) WAS INSTALLED ON THE REPORTED INSERTER, BUT WHEN ATTEMPTED TO INSERT INTO INTERVERTEBRAL SPACE, THE ANGLE OF THE CAGE CHANGED. THE INTERVERTEBRAL FORAMINA HAD OSTEOPETROSIS. THEREFORE, AFTER SCRAPING THE OUTER BONE, THE CAGE WAS RE-INSTALLED ON THE SAME INSERTER AND INSERTED AGAIN. BEFORE INSERTING THE CAGE, THE TRAIL WAS NOT USED/TRIED; AND A ROTATE DISTRACTOR OF 8 MM WAS IMPLEMENTED. WHEN INSTALLING THE CAGE TO THE INSERTER, IT WAS INSTALLED STRAIGHTLY ACCORDING TO THE PROCEDURE MANUAL, AND TIGHTENED THE THUMB WHEEL MORE, AND WAS PROPERLY INSTALLED. THE PARALYSIS ON THE PATIENT PREDICTED POST-OPERATIVELY, BUT
Patient problems: Paralysis; Spinal Cord Injury
MAUDE report 13862242 ↗
Other Intervertebral fusion device with bone graft, lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page