CoreValve™ Evolut™ PRO EVOLUTPRO-29-US (UDI 00643169954458)Recalls & reported problems
Medtronic Corevalve LLC · VLV EVOLUTPRO-29-US PRO BLNK US · Class 3 · Implant
All models of Medtronic Evolut TAVR (45) · CoreValve Evolut PRO (6)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
Quick summary
This Medtronic CoreValve Evolut PRO is a replacement aortic heart valve placed through a catheter. Of its 275 reports, 240 are injury reports, 18 are malfunction reports, and 17 deaths are listed. Many describe leaks around the valve, the valve shifting out of place, and narrowing years after implantation, sometimes requiring another valve or surgery. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 276
- Deaths reported
- 17
- Injuries reported
- 241
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 276 adverse event reports that list this exact device (DI 00643169954458), received between Apr 27, 2017 and Sep 18, 2026 — classified as 17 deaths, 241 injuries, 18 malfunctions.
The most frequently reported specific device problem is “Perivalvular Leak” (71 reports).
4 other recalls cover devices cleared under the same FDA submission (P130021); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem80
- Perivalvular Leak71
- Device Dislodged or Dislocated62
- Patient Device Interaction Problem34
- Intravalvular regurgitation33
- Device Stenosis22
- Gradient Increase20
- Insufficient Device Problem Information20
Patient problems
- No Known Impact Or Consequence To Patient72
- Aortic Valve Insufficiency/ Regurgitation43
- Non specific EKG/ECG Changes31
- Complete Heart Block28
- Aortic Valve Stenosis23
- No Clinical Signs, Symptoms or Conditions23
- Valvular Insufficiency/ Regurgitation21
- Heart Block14
Recent adverse event reports
The 25 most recent of 276 reports, in the reporter's own words as published by the FDA.
InjurySep 18, 2026Intravalvular regurgitation
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 50829256 ↗InjuryJul 30, 2026Intravalvular regurgitation
It was reported that approximately 7 years and 7 months following the implant of a transcatheter aortic valve, the valve failed due to severe central aortic regurgitation. The patient was scheduled for a valve-in-valve replacement for the same day as the onset of the regurgitation.
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 50086518 ↗InjuryJun 10, 2026Device Stenosis
IT WAS REPORTED THAT APPROXIMATELY 8 YEARS AND 1 MONTH FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, THE VALVE FAILED DUE TO STENOSIS. THE PATIENT IS SCHEDULED FOR A VALVE REPLACEMENT APPROXIMATELY 1 MONTH FOLLOWING THE ONSET OF THE VALVE STENOSIS.
Patient problems: Aortic Valve Stenosis
MAUDE report 25460976 ↗InjuryMay 26, 2026Calcified
IT WAS REPORTED THAT APPROXIMATELY 6 YEARS AND 7 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, THE PATIENT WAS RE-HOSPITALIZED DUE TO VALVE CALCIFICATION. SUBSEQUENTLY, THE VALVE WAS EXPLANTED, AND A SURGICAL AORTIC VALVE WAS IMPLANTED.
Patient problems: Calcium Deposits/Calcification
MAUDE report 25283792 ↗InjuryApr 27, 2026Device Stenosis; Unspecified Valve Regurgitation
IT WAS REPORTED THAT 8 YEARS AND 1 MONTH FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, SEVERE REGURGITATION AND AORTIC STENOSIS WERE IDENTIFIED. SUBSEQUENTLY, THE PATIENT WAS HOSPITALIZED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Aortic Valve Stenosis
MAUDE report 25006203 ↗InjuryApr 3, 2026Device Stenosis
IT WAS REPORTED THAT APPROXIMATELY 8 YEARS AND 7 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, THE VALVE FAILED DUE TO STENOSIS.
Patient problems: Aortic Valve Stenosis
MAUDE report 24779476 ↗MalfunctionApr 1, 2026Thickening of Material
IT WAS REPORTED THAT APPROXIMATELY 8 YEARS AND 1 MONTH FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, THE VALVE FAILED DUE TO GRADE I HYPOATTENUATED LEAFLET THICKENING (HALT). MILD TO MODERATE LEAFLET CALCIFICATION AND RESTRICTED MOBILITY OF THE LEAFLETS WERE ALSO OBSERVED. THE PATIENT IS BEING EVALUATED FOR POTENTIAL TREATMENT OPTIONS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24754028 ↗InjuryMar 25, 2026Material Split, Cut or Torn; Intravalvular regurgitation
IT WAS REPORTED THAT 8 YEARS AND 2 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE (TAV), CENTRAL REGURGITATION AND A TORN LEAFLET WERE IDENTIFIED VIA COMPUTED TOMOGRAPHY ANGIOGRAM (CTA). SUBSEQUENTLY, REPLACEMENT FOR THE TRANSCATHETER AORTIC VALVE WAS PLANNED WITH THE USE OF ANOTHER TRANSCATHETER AORTIC VALVE. ADDITIONAL INFORMATION WAS RECEIVED THAT THE SEVERITY OF THE CENTRAL AORTIC REGURGITATION WAS SEVERE. THE PATIENT HAS NOT BEEN SCHEDULED FOR THE TAV-IN-TAV IN YET.
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 24689943 ↗InjuryMar 13, 2026Insufficient Device Problem Information; Patient Device Interaction Problem; Intravalvular regurgitation; Unspecified Valve Regurgitation
ADDITIONAL INFORMATION WAS RECEIVED THAT THE VALVE FAILED DUE TO SEVERE AORTIC REGURGITATION, WHICH WAS IDENTIFIED IN RECENT ECHOCARDIOGRAM REPORTS. IT WAS PLANNED TO TREAT THE FAILED VALVE WITH A NON-MEDTRONIC TRANSCATHETER VALVE.
Patient problems: Heart Failure/Congestive Heart Failure; Hemodynamic instability; Valvular Insufficiency/ Regurgitation
MAUDE report 24594087 ↗MalfunctionFeb 18, 2026Perivalvular Leak; Insufficient Device Problem Information
IT WAS REPORTED THAT APPROXIMATELY 8 YEARS AND 8 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, THE VALVE FAILED DUE TO AN UNSPECIFIED CAUSE. ADDITIONAL INFORMATION WAS RECEIVED THAT THE VALVE FAILED DUE TO MODERATE PARAVALVULAR LEAK (PVL). THERE WAS NO REPORTED INTERVENTION/TREATMENT.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Insufficient Information
MAUDE report 24377388 ↗InjuryFeb 16, 2026Patient Device Interaction Problem; Thickening of Material; Unspecified Valve Regurgitation
IT WAS REPORTED THAT APPROXIMATELY 7 YEARS AND 7 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER VALVE, THE VALVE FAILED DUE TO AN UNKNOWN REASON. THREE MONTHS LATER, A COMPUTED TOMOGRAPHY (CT) SCAN WAS PERFORMED THAT REVEALED POSSIBLE THROMBUS/PANNUS FORMATION INSIDE OF THE VALVE FRAME. SUBSEQUENTLY, INTERVENTION WAS PLANNED BUT HAS NOT BEEN DETERMINED YET. ADDITIONAL INFORMATION WAS RECEIVED THAT THIS TRANSCATHETER VALVE WAS IMPLANTED IN THE PATIENT'S NATIVE ANNULUS AT A FINAL IMPLANT DEPTH OF 4.2 MILLIMETERS (MM) ON THE LEFT CORONARY CUSP (LCC) AND 3.5 MM ON THE RIGHT CORONARY CUSP (RCC). THE MODE OF FAILURE OF THE VALVE WAS AORTIC INSUFFICIENCYOF UNKNOWN TYPE AND SEVERITY. HOWEVER, THERE WAS NO THROMBUS FORMATION. APPROXIMATELY 7 YEARS AND 8 MONTHS FOLLOWING THE IMPLANT OF THIS VALVE, A 23 MM NON-MEDTRONIC TRANSCATHETER VALVE WAS IMPLANTED VALVE-IN-VALVE WITH WIRE PROTECTION AT THE RIGHT CORONARY ARTERY.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Foreign Body Reaction; Thrombosis/Thrombus
MAUDE report 24344407 ↗InjuryJan 8, 2026Intravalvular regurgitation
ADDITIONAL INFORMATION WAS RECEIVED THAT THE SEVERITY OF THE CENTRAL AORTIC REGURGITATION WAS MODERATE TO SEVERE.
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 24012541 ↗InjuryJan 5, 2026Calcified; Fluid/Blood Leak; Gradient Increase; Device Stenosis
ADDITIONAL INFORMATION WAS RECEIVED THAT THE PATIENT WAS DISCHARGED HOME THE DAY AFTER THE VALVE-IN-VALVE PROCEDURE.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Insufficient Information; Transvalvular Pressure Gradient Increased; Tricuspid Valve Insufficiency/ Regurgitation
MAUDE report 23970808 ↗InjuryJan 5, 2026Patient Device Interaction Problem
IT WAS REPORTED THAT 1 DAY FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED DUE TO ASYSTOLE.
Patient problems: Asystole
MAUDE report 23959559 ↗MalfunctionJan 2, 2026Gradient Increase; Patient Device Interaction Problem; Intravalvular regurgitation
IT WAS REPORTED THAT APPROXIMATELY 8 YEARS AND 1 MONTH FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, THE VALVE FAILED DUE TO MODERATE CENTRAL AORTIC REGURGITATION. THE PATIENT SUFFERED HEART FAILURE AND HEMODYNAMIC INSTABILITY AS RESULT.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Heart Failure/Congestive Heart Failure; Hemodynamic instability; Transvalvular Pressure Gradient Increased
MAUDE report 23944777 ↗InjuryDec 30, 2025Intravalvular regurgitation; Intravalvular regurgitation
IT WAS REPORTED THAT 7 YEARS AND 10 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, CENTRAL REGURGITATION OF SEVERE SEVERITY WAS IDENTIFIED. SUBSEQUENTLY, A 23 MM NON-MEDTRONIC WAS IMPLANTED VALVE-IN-VALVE.
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 23921702 ↗InjuryDec 26, 2025Patient Device Interaction Problem; Patient Device Interaction Problem
IT WAS REPORTED THAT 2 DAYS FOLLOWING THE IMPLANT OF THIS TRANSCATHETER BIOPROSTHETIC VALVE, A PERMANENT PACEMAKER WAS IMPLANTED DUE TO COMPLETE HEART BLOCK (CHB).
Patient problems: Heart Block
MAUDE report 23897066 ↗InjuryDec 21, 2025Calcified; Gradient Increase; Device Stenosis; Calcified; Gradient Increase; Device Stenosis
IT WAS REPORTED APPROXIMATELY EIGHT YEARS FOLLOWING THE IMPLANT OF THIS 29MM TRANSCATHETER AORTIC BIOPROSTHETIC VALVE (TAV), VALVE FAILURE WAS REPORTED. THE PRIMARY MODE OF VALVE FAILURE WAS STRUCTURAL VALVE DETERIORATION: PREDOMINANT AORTIC STENOSIS (AS) WITH SEVERE HEMODYNAMIC VALVE DETERIORATION. THIS WAS CHARACTERIZED BY AN INCREASE IN MEAN GRADIENT OF >=20MM HG FROM BASELINE AND A MEAN GRADIENT OF >=30MM HG. THE PATIENT WAS ENROLLED IN A CLINICAL STUDY WITH EXISTING, BASELINE VALVE FAILURE TO DETERMINE WHETHER A REDO-TAV REPLACEMENT PROCEDURE, TAV-IN-TAV, WAS APPROPRIATE. NO PATIENT SYMPTOMS PRIOR TO WERE REPORTED AS A RESULT OF THIS EVENT.
Patient problems: Insufficient Information; Mitral Valve Insufficiency/ Regurgitation; Tricuspid Valve Insufficiency/ Regurgitation
MAUDE report 23860468 ↗InjuryDec 17, 2025Perivalvular Leak; Intravalvular regurgitation; Perivalvular Leak; Intravalvular regurgitation
ADDITIONAL INFORMATION WAS RECEIVED THAT THE SEVERITY OF THE PARAVALVULAR LEAK (PVL) WAS MODERATE.
Patient problems: Valvular Insufficiency/ Regurgitation
MAUDE report 23831243 ↗InjuryDec 12, 2025Perivalvular Leak; Patient Device Interaction Problem; Perivalvular Leak; Patient Device Interaction Problem
IT WAS REPORTED THAT APPROXIMATELY 8 YEARS AND 1 MONTH FOLLOWING THE IMPLANT OF A TRANSCATHETER VALVE, THE VALVE FAILED DUE TO SEVERE PARAVALVULAR LEAK (PVL) AND THE PATIENT WAS HOSPITALIZED. ADDITIONALLY, CONGESTIVE HEART FAILURE (CHF) OCCURRED AND WAS ATTRIBUTED TO THE VALVE. SUBSEQUENTLY, A SECOND TRANSCATHETER VALVE WAS IMPLANTED VALVE-IN-VALVE.
Patient problems: Heart Failure/Congestive Heart Failure; Valvular Insufficiency/ Regurgitation
MAUDE report 23793886 ↗InjuryDec 8, 2025Intravalvular regurgitation; Intravalvular regurgitation
IT WAS REPORTED THAT APPROXIMATELY 8 YEARS AND 3 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, MODERATE CENTRAL AORTIC REGURGITATION WAS OBSERVED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 23743291 ↗InjuryNov 20, 2025Device Stenosis; Intravalvular regurgitation; Device Stenosis; Intravalvular regurgitation
IT WAS REPORTED THAT APPROXIMATELY 7 YEARS AND 11 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, MODERATE-SEVERE CENTRAL AORTIC REGURGITATION AND AORTIC STENOSIS WERE OBSERVED. SUBSEQUENTLY, A SECOND MEDTRONIC TRANSCATHETER VALVE WAS IMPLANTED VALVE-IN-VALVE. THE PATIENT WAS DOING WELL POST-OPERATIVELY.
Patient problems: Aortic Valve Insufficiency/ Regurgitation; Aortic Valve Stenosis
MAUDE report 23605352 ↗MalfunctionNov 18, 2025Intravalvular regurgitation; Intravalvular regurgitation
IT WAS REPORTED THAT APPROXIMATELY EIGHT YEARS AND TWO MONTHS FOLLOWING THE IMPLANT OF THIS VALVE, IT WAS IDENTIFIED THAT THE VALVE FAILED. STRUCTURAL VALVE DETERIORATION WITH MODERATE HEMODYNAMIC VALVE DETERIORATION (HVD) SPECIFIED AS A NEW OCCURRENCE OR INCREASE OF >=1 GRADE OF INTRA-PROSTHETIC AORTIC REGURGITATION (AR) RESULTING IN >=MODERATE AR. NO INTERVENTION WAS REPORTED.
Patient problems: Aortic Valve Insufficiency/ Regurgitation
MAUDE report 23585724 ↗MalfunctionNov 17, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT APPROXIMATELY 7 YEARS AND 1 MONTH FOLLOWING THE IMPLANT OF A TRANSCATHETER AORTIC VALVE, AN UNSPECIFIED VALVE FAILURE WAS OBSERVED. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23570619 ↗InjuryNov 12, 2025Patient Device Interaction Problem; Thickening of Material; Intravalvular regurgitation; Patient Device Interaction Problem; Thickening of Material; Intravalvular regurgitation
IT WAS REPORTED THAT APPROXIMATELY 7 YEARS AND 4 MONTHS FOLLOWING THE IMPLANT OF A TRANSCATHETER VALVE, THE VALVE FAILED DUE TO SEVERE CENTRAL AORTIC REGURGITATION. A COMPUTED TOMOGRAPHY (CT) SCAN WAS PERFORMED THAT REVEALED POSSIBLE THROMBUS/PANNUS FORMATION INSIDE THE VALVE FRAME. SUBSEQUENTLY, THE PATIENT WAS EVALUATED FOR A POSSIBLE TRANSCATHETER AORTIC VALVE-IN-TRANSCATHETER AORTIC VALVE REPLACEMENT OR EXPLANT, AND WAS TRANSFERRED TO A DIFFERENT HOSPITAL.
Patient problems: Foreign Body Reaction; Thrombosis/Thrombus; Valvular Insufficiency/ Regurgitation
MAUDE report 23534966 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under P130021. One submission often covers many models, so check the product and lot details in each record.
- Z-0559-2021 · Oct 23, 2020 · TerminatedEvolut (TM) R System. With the following model numbers: a. EVOLUTR-23, Labeled as VLV EVOLUTR-23 VT IR 6L COMM OUS, VLV EVOLUTR-23 TAV EVOLUT R CE 29L MX, VLV EVOLUTR-23 TAV
- Z-0560-2021 · Oct 23, 2020 · TerminatedEvolut (TM) PRO System. With the following model numbers: a. EVOLUTPRO-23, Labeled as: VLV EVOLUTPRO-23 PRO COMM 29L OUS, VLV EVOLUTPRO-23 BLUE 29L COMM OUS, VLV EVOLUTPRO-23
- Z-0561-2021 · Oct 23, 2020 · TerminatedEvolut (TM) PRO+ System. With the following model numbers: a. EVPROPLUS-23US, Labeled as VLV EVPROPLUS-23US COMM JPN, VLV EVPROPLUS-23 COMM US; b. EVPROPLUS-26US, Labele
- Z-2264-2015 · Jul 15, 2015 · TerminatedEnVeo R Loading System, Model No. LS-EnVeoR-23, LS-EnVeoR-2629, LS-EnVeoR-23-C, LS-EnVeoR-2629-C. Cardiovascular valve delivery system for use with the Medtronic CoreValve Evol
Other Aortic valve, prosthesis, percutaneously delivered devices
- Evolut™ PRO+ EVPROPLUS-29USMedtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered57 deaths869 reports
- Evolut™ PRO+ EVPROPLUS-34USMedtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered43 deaths613 reports
- CoreValve™ Evolut™ PRO EVOLUTPRO-29-USMedtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered30 deaths596 reports
- Evolut™ PRO+ EVPROPLUS-26USMedtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered66 deaths578 reports
- Evolut™ FX EVOLUTFX-29Medtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered47 deaths564 reports
- Evolut™ FX EVOLUTFX-34Medtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered22 deaths563 reports
- Evolut™ FX D-EVOLUTFX-2329Medtronic Corevalve LLC · Aortic valve, prosthesis, percutaneously delivered79 deaths555 reports
- Navitor™ NVRO-27St. Jude Medical, Inc. · Aortic valve, prosthesis, percutaneously delivered1 recall35 deaths471 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page