EverCross™ AB35W06120135 (UDI 00643169973978)Recalls & reported problems

Ev3, Inc · PTA AB35W06120135 EVERCROSS 035 V08 · Class 2

All models of EverCross (114)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00643169973978), received between Nov 1, 2024 and Nov 1, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Burst Container or Vessel” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Burst Container or Vessel1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 1, 2024Burst Container or Vessel; Burst Container or Vessel

    TWO EVERCROSS PTA BALLOONS WERE USED DURING TREATMENT OF A 150MM CALCIFIED LESION WITH 60% STENOSIS IN THE PROXIMAL REGION OF THE LEFT IN THE SUPERFICIAL FEMORAL ARTERY. THE ARTERY WAS 6MM IN DIAMETER WITH MODERATE CALCIFICATION AND TORTUOSITY. A 6FR NON MEDTRONIC SHEATH AND A 0.035" NON MEDTRONIC GUIDEWIRE WAS USED. EMBOLIC PROTECTION WAS NOT USED. THE VESSEL WAS PRE-DILATED WITH A 4X100 NANOCROSS AND A TURBOHAWK PLUS. THERE WAS NO RESISTANCE DURING ADVANCEMENT. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. AN UNKNOWN INFLATION DEVICE WAS USED WITH 50/50 CONTRAST. IT WAS REPORTED FOR BOTH BALLOONS ON THE FIRST INFLATION, THE BALLOON BURST AT 8ATM. THE BALLOON DID NOT DETACH. THE TYPE OF BALLOON BURST IS NOT KNOWN. THE DEVICE WAS SAFELY REMOVED FROM THE PATIENT. A 6X80MM EVERCROSS WAS USED TO COMPLETE THE CASE. NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20585683 ↗