Skip to content

EverCross™ AB35W06200135 (UDI 00643169974012)Recalls & reported problems

Ev3, Inc · PTA AB35W06200135 EVERCROSS 035 V08 · Class 2

All models of EverCross (114)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
1
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 00643169974012), received between Jan 4, 2021 and Feb 1, 2024 — classified as 1 death, 3 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Burst Container or Vessel” (6 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Burst Container or Vessel6
  • Detachment of Device or Device Component2
  • Difficult to Remove1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Hemorrhage/Blood Loss/Bleeding1
  • Perforation1
  • Perforation of Vessels1
  • Unspecified Tissue Injury1

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 1, 2024Burst Container or Vessel; Burst Container or Vessel

    IT WAS REPORTED THAT AN ATTEMPT WAS MADE TO USE A EVERCROSS TO TREAT A CALCIFIED LESION IN THE MID SUPERFICIAL FEMORAL ARTERY. DEGREE OF TORTUOSITY WAS LITTLE. DEGREE OF CALCIFICATION WAS MODERATE. A 6F DESTINATION SHEATH WAS USED. A .035 STIFF GLIDE GUIDEWIRE WAS USED. EMBOLIC PROTECTION WAS NOT USED. AN INFLATION DEVICE WAS USED. DEVICE WAS PREPPED PER IFU. THERE WAS A LONGITUDINAL BALLOON BURST ON THE FIRST INFLATION AT 8ATMS. AFTER LOADING ONTO THE PRIMARY GUIDEWIRE, THE PHYSICIAN NOTED THAT CONTRAST WAS SEEN EXITING THE BALLOON AFTER THE TECH USED AN INFLATION DEVICE TO TAKE IT TO NOMINAL. AFTER THE BURST BALLOON WAS REMOVED, THE PHYSICIAN ASKED FOR A SECOND 6X200 EVERCROSS TO BE OPENED. AFTER IFU PREP AND INSPECTION, THE PHYSICIAN WAS ABLE TO INFLATE THIS PTA BALLOON TO NOMINAL PRESSURE AND WAS ABLE TO COMPLETE PROCEDURE WITH NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18623875 ↗
  • InjuryOct 13, 2023Burst Container or Vessel; Difficult to Remove; Detachment of Device or Device Component; Burst Container or Vessel; Difficult to Remove; Detachment of Device or Device Component

    PHYSICIAN ATTEMPTED TO USE AN EVERCROSS PTA BALLOON DURING TREATMENT OF A CALCIFIED LESION IN THE PATIENTS RIGHT PROXIMAL SUPERFICIAL FEMORAL ARTERY (SFA). MODERATE VESSEL TORTUOSITY AND SEVERE VESSEL CALCIFICATION ARE REPORTED. LESION EXHIBITED 90% STENOSIS. EMBOLIC PROTECTION WAS NOT USED. A NON-MEDTRONIC (COOK) INFLATION DEVICE WAS USED FOR BALLOON INFLATION. THERE WAS NO DAMAGE NOTED TO PACKAGING, I.E. SHELF CARTON, HOOP/TRAY. NO ISSUES WERE NOTED WHEN REMOVING THE DEVICE FROM THE HOOP/TRAY. IFU WAS FOLLOWED AND THE DEVICE WAS PREPPED WITHOUT ISSUE. 50 CONTRAST/ 50 SALINE WAS USED. THE VESSEL WAS PRE-DILATED WITH A 5X120 CHOCOLATE BALLOON. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. NO RESISTANCE WAS NOTED DURING ADVANCEMENT OF THE DEVICE. PHYSICIAN BALLOONED THE SFA AND UPON DEFLATION FROM RBP TO 0 THE BALLOON BURST. ISSUE OCCURRED ON FIRST INFLATION. AS THE PHYSICIAN WAS REMOVING THE BALLOON FROM THE CONTRALATERAL SHEATH IN THE GROIN, THE CATHETER THAT THE BALLOON WAS MOUNTED ON BROKE OFF IN THE PATIENT. PHYSICIAN WAS ABLE TO REMOVE BALLOON (FULLY INTACT ON THE CATHETER THAT THE BALLOON IS MOUNTED ON) AND THE CATHETER BY GOING UP THE LEG DISTALLY BY STICKING

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17929886 ↗
  • DeathMay 12, 2022Burst Container or Vessel; Detachment of Device or Device Component; Burst Container or Vessel; Detachment of Device or Device Component

    A PHYSICIAN USED AN EVERCROSS PTA BALLOON DURING TREATMENT OF A CALCIFIED CTO (CHRONIC TOTAL OCCLUSION-100%) IN THE PATIENT'S MID SUPERFICIAL FEMORAL ARTERY (SFA). SEVERE VESSEL CALCIFICATION IS REPORTED. AN INFLATION DEVICE WAS USED FOR BALLOON INFLATION. IT IS REPORTED THE BALLOON BURST AND CAME OFF THE SHAFT OF THE DEVICE. HAEMORRHAGE/BLEED IS REPORTED. DURING THE ATTEMPT TO RETRIEVE THE BALLOON THE ILIAC ARTERY WAS PERFORATED. THE PATIENT IS REPORTED TO BE DECEASED.

    Patient problems: Hemorrhage/Blood Loss/Bleeding; Perforation of Vessels

    MAUDE report 14375453 ↗
  • InjuryAug 24, 2021Burst Container or Vessel; Burst Container or Vessel

    PHYSICIAN WAS ATTEMPTING TO USE AN EVERCROSS PTA BALLOON ALONG WITH A 6FR SHEATH DURING PROCEDURE TO TREAT A MODERATELY CALCIFIED LESION IN THE MID SUPERFICIAL FEMORAL ARTERY (SFA). THE VESSEL WAS MODERATELY TORTUOUS. AN INFLATION DEVICE WAS USED FOR BALLOON INFLATION. THERE WAS NO DAMAGE NOTED TO PACKAGING. THERE WAS NO ISSUE NOTED WHEN REMOVING THE DEVICE FROM HOOP/TRAY. THE DEVICE WAS PREPPED PER IFU WITH NO ISSUES IDENTIFIED. THE DEVICE DID NOT PASS THROUGH A PREVIOUSLY DEPLOYED STENT. THERE WAS NO RESISTANCE ENCOUNTERED WHEN ADVANCING THE DEVICE. IT WAS REPORTED THAT DURING BALLOON INFLATION, BALLOON BURST OCCURRED AT 11ATM (RBP). 1 PRIOR INFLATION WAS APPLIED TO THE DEVICE FOR 40 SECONDS PRIOR TO THE ISSUE OCCURRING. PHYSICIAN SNARED THE BALLOON AFTER TWO ATTEMPTS. IT IS REPORTED AORTIC INJURY OCCURRED WHILE SNARING THE BALLOON MATERIAL THAT RUPTURED. VESSEL PERFORATION IS REPORTED. PHYSICIAN CARRIED OUT AAA REPAIRS WITH COVERED STENT DAMAGED AORTA WHICH WAS CAUSED WHILE RETRIEVING THE PTA MATERIAL THAT BROKE OFF. ALL FRAGMENTS OF THE BALLOON WERE RETRIEVED. NO FURTHER INJURY REPORTED.

    Patient problems: Perforation

    MAUDE report 12357948 ↗
  • InjuryFeb 9, 2021Burst Container or Vessel; Burst Container or Vessel

    IT WAS REPORTED THAT A PHYSICIAN WAS ATTEMPTING TO USE AN EVERCROSS PTCA BALLOON TO TREAT A LESION THE RIGHT PROXIMAL SUPERFICIAL FEMORAL ARTERY IN A PATIENT. THE LESION WAS FIBROUS, WITH LITTLE TORTUOSITY, AND LITTLE CALCIFICATION. A NON-MEDTRONIC SHEATH WAS USED WITH A NON-MEDTRONIC GUIDEWIRE AND NON-MEDTRONIC. A SPIDER EMBOLIC PROTECTION DEVICE WAS USED. NO DAMAGE WAS NOTED TO PACKAGING, I.E. SHELF CARTON, HOOP/TRAY. NO ISSUES WERE NOTED WHEN REMOVING THE DEVICE FROM THE HOOP/TRAY. THE DEVICE WAS PREPPED AS PER IFU. IT WAS REPORTED THAT A CIRCUMFERENTIAL/RADIAL BALLOON BURST DURING INFLATION AT 14 ATM. THE BALLOON WAS INFLATED IN THE STENT AND IT BURST. THE BALLOON ENCOUNTERED RESISTANCE WHEN REMOVED AND APPEARED TO HAVE PARACHUTED DOWN THE CATHETER. THE CATHETER WAS REMOVED FROM THE PATIENT WITH A PORTION OF THE BALLOON MATERIAL REMAINING ON THE WIRE INSIDE THE PATIENT NEAR THE TIP OF THE SHEATH NOW IN THE LEFT COMMON FEMORAL. THIS WAS THEN ATTEMPTED TO BE REMOVED BY TWO SNARES. SUCCESSFUL REMOVAL OF THE MATERIAL OCCURRED USING A SINGLE USE RADIAL JAW BIOPSY FORCEPS. ALL FRAGMENTS WERE REMOVED FROM THE PATIENT. NO FURTHER PATIENT INJURY WAS REPORTED FOR THIS EVENT

    Patient problems: Unspecified Tissue Injury

    MAUDE report 11300844 ↗
  • MalfunctionJan 4, 2021Burst Container or Vessel; Burst Container or Vessel

    PHYSICIAN INTENDED TO USE AN EVERCROSS PTA BALLOON WITH A 5FR/6FR SHEATH AND 2 NON-MEDTRONIC 0.035 GUIDEWIRES DURING TREATMENT OF A 250MM CALCIFIED CTO (CHRONIC TOTAL OCCLUSION-100%) IN THE PATIENT¿S MID LEFT SUPERFICIAL FEMORAL ARTERY (SFA). SEVERE VESSEL CALCIFICATION AND TORTUOSITY IS REPORTED. ARTERY DIAMETER REPORTED AS 6MM. THERE WAS NO DAMAGE NOTED TO THE PRODUCT PACKAGING PRIOR TO USE. NO ISSUES WERE NOTED WHEN REMOVING THE DEVICE FROM THE PACKAGING. A NON-MEDTRONIC INFLATION DEVICE WAS USED FOR BALLOON INFLATION. THE DEVICE WAS PASSED THROUGH A PREVIOUSLY DEPLOYED STENT AND RESISTANCE WAS NOTED. A CIRCUMFERENTIAL BALLOON BURST IS REPORTED AT NOMINAL PRESSURE (8ATM). NO BALLOON FRAGMENTS REMAINED IN THE PATIENT. A SECOND EVERCROSS PTA BALLOON WAS OPENED AND PREPPED WITHOUT ISSUE. THERE WAS NO DAMAGE NOTED TO THE PRODUCT PACKAGING PRIOR TO USE. NO ISSUES WERE NOTED WHEN REMOVING THE DEVICE FROM THE PACKAGING. A NON-MEDTRONIC INFLATION DEVICE WAS USED FOR BALLOON INFLATION. THE DEVICE WAS PASSED THROUGH A PREVIOUSLY DEPLOYED STENT AND RESISTANCE WAS NOTED. A CIRCUMFERENTIAL BALLOON BURST IS REPORTED AT 10ATM. NO BALLOON FRAGMENTS REMAINED IN THE PATIENT. A NON-M EDTRONIC BALL

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11108092 ↗

Other Catheter, percutaneous devices

All Catheter, percutaneous devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page