EverCross™ AB35W07150135Recalls & reported problems
Ev3, Inc · PTA AB35W07150135 EVERCROSS 035 V08 · Class 2
All models of EverCross (114)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00643169974203), received between Mar 14, 2025 and Sep 30, 2026 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Burst Container or Vessel” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Burst Container or Vessel2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 30, 2026Burst Container or Vessel
It was reported that during a procedure using an Evercross PTA balloon catheter, for the treatment of a plaque lesion in the mid section of the right superficial femoral artery (vessel diameter; 6.5 mm), the balloon experienced a pinhole type balloon burst (Balloon Burst AT, BELOW, or UNKNOWN Rated Burst Pressure) on the first inflation. The vessel was post- dilated. The device did not pass through a previously deployed stent. No resistance was encountered when advancing the device. The balloon was inflated with a (Cook Medical) inflation device and 50/50 contrast inflation fluid was used. No damage was noted to the packaging and no issues were noted when removing the device from the hoop/tray. The instructions for use were followed without issue. It is not known at what pressure the balloon burst. The balloon did not detach during the procedure. The device was safely removed from the patient. The procedure was completed using a new (Medtronic) device. The patient was reported as alive, with no injury. No injury or intervention was associated with this event. No patient symptoms or complications have been reported as a result of this event. It was reported that there was a 3 minute
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50947116 ↗MalfunctionMar 14, 2025Burst Container or Vessel; Burst Container or Vessel
A PHYSICIAN WAS USING AN EVERCROSS PTA BALLOON FOR TREATMENT OF A SEVERELY CALCIFIED LESION IN THE MID RIGHT SUPERFICIAL FEMORAL ARTERY. A 6FR NON-MEDTRONIC SHEATH AND A 0.035 NON-MEDTRONIC GUIDEWIRE WERE USED. THE VESSEL WAS NOT PRE-DILATED. THE BALLOON PASSED THROUGH A PREVIOUSLY DEPLOYED EVERFLEX STENT. NO RESISTANCE WAS MET. A NON-MEDTRONIC INFLATION DEVICE WAS USED WITH 50/50 CONTRAST. IT WAS REPORTED DURING THE SECOND INFLATION THE BALLOON BURST LONGITUDINALLY. IT IS NOT KNOWN AT WHAT PRESSURE THE BALLOON BURST. THE BALLOON DID NOT DETACH AND IT WAS SAFELY REMOVED FROM THE PATIENT. ANOTHER EVERCROSS BALLOON WAS USED TO COMPLETE THE CASE. NO PATIENT INJURY WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21604247 ↗
Other Catheter, percutaneous devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page