ADVANTA SLIDER GDS 22115Recalls & reported problems

Atrium Medical Corporation · 4-7MMX45CM, SW, SH, ADVANTA VXT, GDS · Class 2 · Implant

All models of ADVANTA SLIDER GDS (51)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
9
Deaths reported
0
Injuries reported
2
Recalls naming it
1

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 00650862221152), received between Mar 19, 2017 and Nov 5, 2024 — classified as 2 injuries, 7 malfunctions.

The most frequently reported specific device problem is “Material Deformation” (5 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. May 3, 2024Open, Classified

    Complaints of reported separation of the Slider GDS Swivel Rod from the Swivel Core and of a notable gap between the two pieces.

    Z-1994-2024 · Root cause: Equipment maintenance · Recall details · FDA record ↗

Most reported problems

Device problems

  • Material Deformation5
  • Adverse Event Without Identified Device or Use Problem1
  • Break1
  • Material Integrity Problem1
  • Material Split, Cut or Torn1

Patient problems

  • No Clinical Signs, Symptoms or Conditions8
  • Fluid Discharge1
  • Insufficient Information1

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 5, 2024Material Split, Cut or Torn; Material Split, Cut or Torn

    AFTER AN ARTERIOVENOUS GRAFT (AVG) SURGERY OF THE LEFT ARM, ABNORMAL BLOOD FLOW LEVELS WERE OBSERVED. UPON CUTTING IT OPEN, IT WAS DISCOVERED THAT THE MIDDLE PART OF THE GRAFT WAS TORN. BY VISUAL INSPECTION OF THE GRAFT, BOTH OF THE INNER AND OUTER SURFACE SEEMS TO BE TORN. TO VERIFY THE GRAFT, THE END OF VXT 22115, WHICH HAD BEEN REMOVED, WAS REPLACED WITH VXT 22012, AND THE GRAFT WAS RECONNECTED. THE SURGERY WAS DELAYED BY 30 MINUTES TO 1 HOUR WITH NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20615495 ↗
  • MalfunctionMar 7, 2024Break; Break

    N/A

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18860894 ↗
  • MalfunctionMay 1, 2023Material Deformation; Material Deformation

    N/A.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16843212 ↗
  • MalfunctionApr 30, 2023Material Deformation; Material Deformation

    N/A.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16841453 ↗
  • MalfunctionApr 3, 2023Material Deformation; Material Deformation

    AFTER OPENING, THE THICKNESS OF THE GRAFT WAS NOT CONSISTENT, WE REQUESTED A RETURN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16667702 ↗
  • MalfunctionApr 3, 2023Material Deformation; Material Deformation

    AFTER OPENING, THE THICKNESS OF THE GRAFT WAS NOT CONSISTENT, WE REQUESTED A RETURN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16667696 ↗
  • MalfunctionFeb 21, 2023Material Deformation; Material Deformation

    THE HOSPITAL CONSISTENTLY USES THE SAME MODEL GRAFT, AND UNLIKE USUAL USE, IT IS SAID THAT THE UPPER PART WAS THIN AND THE LOWER PART WAS THICK BASED ON THE BLUE LINE OF THE GRAFT. HE WANTS TO ASK THE MANUFACTURER IF THERE IS ANY PROBLEM WITH USING THE NEEDLE WHEN THE THIN PART IS DIALYSIS. THERE WAS NO PROBLEM WITH THE OPERATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16410291 ↗
  • MalfunctionApr 19, 2022Material Integrity Problem; Material Integrity Problem

    IT WAS REPORTED THAT DURING RINSING BEFORE AVF SURGERY, AND AS A RESULT OF PRELIMINARY EXPERIMENTS THROUGH BLOOD VESSELS BY EXTRACTING THE PATIENT'S BLOOD BEFORE SURGERY AT THAT TIME, STENOSIS OCCURRED DUE TO THE REMARKABLY THIN BLOOD VESSEL THICKNESS ON ONE SIDE. ONE SIDE OF THE THIN SIDE IS NOT MAINTAINED IN THE FORM OF A TUBE, AND THE OTHER SIDE IS SHRUNK. PROCEDURE COMPLETED WITH ANOTHER DEVICE SAME MODEL.

    Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions

    MAUDE report 14140816 ↗
  • InjuryMar 19, 2017Adverse Event Without Identified Device or Use Problem

    GRAFT WAS WEEPING CLEAR FLUID NOT BLOOD AFTER IMPLANTATION. THE CLEAR SERUM FLUID WAS SWEATING THROUGH THE GRAFT CONTINUALLY. THE GRAFT HAD TO BE EXPLANTED AND NEW GRAFT WAS USED.

    Patient problems: Fluid Discharge

    MAUDE report 6416357 ↗

Other PROSTHESIS, VASCULAR GRAFT, OF LESS THEN 6MM DIAMETER devices

All PROSTHESIS, VASCULAR GRAFT, OF LESS THEN 6MM DIAMETER devices →