Becker® 46129 (UDI 00673978228761)Recalls & reported problems
Medtronic Ps Medical, Inc. · EDMS 46129 EURO BECKER II BLUE PT LN · Class 2
All models of Becker (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00673978228761), received between Mar 17, 2017 and Feb 2, 2018 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Occlusion Within Device” (1 report).
6 other recalls cover devices cleared under the same FDA submission (K984053); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Appropriate Device Problem Term/Code Not Available1
- Occlusion Within Device1
Patient problems
- No Known Impact Or Consequence To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 2, 2018Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
IT WAS REPORTED THAT AT 2100 HOURS ON (B)(6) 2017, THE CEREBROSPINAL FLUID (CSF) WAS OSCILLATING, BUT NOT DRAINING INTO THE CHAMBER. THE INTRACRANIAL PRESSURE (ICP) WAVEFORM WAS GOOD. FIFTEEN MINUTES LATER, THE DOCTOR WITHDREW THE EXTERNAL VENTRICULAR DRAIN (EVD) BY 1 CM AND RE-STITCHED. THE CSF WAS STILL OSCILLATING AND NOT DRAINING. THE DOCTOR THEN TRIED ASPIRATING AND FLUSHING FROM THE 3-WAY CONNECTOR TO THE CHAMBER AND WAS SUCCESSFUL. HOWEVER, WHEN THEY TURNED THE 3-WAY CONNECTOR TO DRAIN FROM PATIENT, THE PRESSURE WAS HIGH, AND CSF WAS FLOWING OUT AT A HIGH FLOW RATE. THE DOCTOR MANAGED TO ASPIRATE ABOUT 15 ML FROM THE PATIENT AT THE 3-WAY CONNECTOR. WHEN TURNING THE 3-WAY (PATIENT TO CHAMBER), CSF WAS BACKFLOWING. WHEN THE EVD WAS BROUGHT AT A LOWER HEIGHT, THE CSF WAS OSCILLATING AND NOT DRAINING. THE DOCTOR SUSPECTED THE EVD SYSTEM WAS FAULTY AND REQUESTED THE NURSES TO CHANGE THE DRAINAGE BAG. BETWEEN 2130-2145 HOURS, THE EVD DRAINAGE BAG WAS CHANGED, BUT THE SYSTEM WAS STILL NOT DRAINING CSF INTO THE CHAMBER. THE ISSUE WAS ATTEMPTED TO BE RECTIFIED BY SCRUBBING, THEN ASPIRATING FROM THE Y-SITE CONNECTOR BELOW THE CHAMBER. THEY COULD ASPIRATE SLIGHTLY, HOWEVER CSF WAS STIL
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7236062 ↗MalfunctionMar 17, 2017Occlusion Within Device; Occlusion Within Device
IT WAS REPORTED TO MEDTRONIC NEUROSURGERY THAT THE SYSTEM DID NOT DRAIN INTRA-OPERATIVELY. ACCORDING TO THE REPORT, THE SYSTEM WAS CHANGED OUT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6415492 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K984053. One submission often covers many models, so check the product and lot details in each record.
- Z-2412-2023 · Jun 28, 2023 · Open, ClassifiedMedtronic REF 46915 Duet External Drainage and Monitoring system, Interlink Injection sites, Ventricular Catheter, STERILE EO, Rx Only
- Z-1921-2014 · Jun 9, 2014 · TerminatedMedtronic Duet External Drainage and Monitoring System, SmartSite Injection Sites, Catalog No. 46914. Intended to allow drainage and measurement of cerebrospinal fluid (CSF) and o
- Z-1920-2014 · Jun 9, 2014 · TerminatedMedtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Catalog No. 46913. Intended to allow drainage and measurement of cerebrospinal fluid (CSF) and o
- Z-1924-2014 · Jun 9, 2014 · TerminatedMedtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Lumbar Catheter, Catalog No. 46917. Intended to allow drainage and measurement of cerebrospinal
- Z-1922-2014 · Jun 9, 2014 · TerminatedMedtronic Duet External Drainage and Monitoring System, Interlink Injection Sites, Ventricular Catheter, Catalog No. 46915. Intended to allow drainage and measurement of cerebrosp
- Z-1923-2014 · Jun 9, 2014 · TerminatedMedtronic Duet External Drainage and Monitoring System, SmartSite Injection Sites, Ventricular Catheter, Catalog No. 46916. Intended to allow drainage and measurement of cerebrosp
Other Shunt, central nervous system and components devices
- NATUS EDS3 DRAINAGE SYSTEM NT821731CNatus Medical Incorporated · Shunt, Central Nervous System And Components1 recall208 reports
- Exacta™ 46700Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall2 deaths163 reports
- Strata® 42866Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 death160 reports
- proGAV 2.0® FX410TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components119 reports
- Becker® 46128Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall50 reports
- PROGAV 2.0 FX643TAesculap AG · Shunt, central nervous system and components100 reports
- M.BLUE PLUS FX804TAesculap AG · Shunt, central nervous system and components82 reports
- proSA® FV701TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components82 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page