Capiox® FX Advance Hollow Fiber Oxygenator w Integrated AF w Hardshell Res. 3CX*FX15RW40CRecalls & reported problems
Terumo Cardiovascular Systems Corporation · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
Quick summary
This Terumo Capiox oxygenator is used in cardiopulmonary bypass. Reports describe leaks, cracks, high pressure, and units damaged before use; some mention blood loss, though many report no patient harm. There are 79 adverse event reports naming this device identifier: 3 deaths, 9 injuries, 67 malfunctions. This device has no recalls.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 79
- Deaths reported
- 3
- Injuries reported
- 9
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 79 adverse event reports that list this exact device (DI 00699753450790), received between May 22, 2018 and Aug 7, 2026 — classified as 3 deaths, 9 injuries, 67 malfunctions.
The most frequently reported specific device problem is “Leak/Splash” (10 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Leak/Splash10
- Use of Device Problem10
- Crack6
- Increase in Pressure6
- Device Damaged Prior to Use5
- Defective Device4
- Manufacturing, Packaging or Shipping Problem4
- Pressure Problem4
Patient problems
- No Clinical Signs, Symptoms or Conditions38
- No Patient Involvement17
- Blood Loss10
- No Known Impact Or Consequence To Patient7
- No Consequences Or Impact To Patient3
- Death2
- Hemorrhage/Blood Loss/Bleeding2
- Injury2
Recent adverse event reports
The 25 most recent of 79 reports, in the reporter's own words as published by the FDA.
DeathAug 7, 2026Use of Device Problem
The user facility reported to Terumo Cardiovascular that during cardiopulmonary bypass there was an oxygenator failure while rewarming after circulatory arrest at 28 Degrees Celsius. As per the subsidiary, it resulted to prolonged hypoxia approximately 20 minutes. There was cerebral desaturation documented by Near-Infrared Spectroscopy (NIRS). There was a significant hemodynamic instability and worsening of the patient's condition intraoperatively and postoperatively. Actions were taken through emergency replacement of the oxygenator, massive blood transfusion, device was not retained for further investigation. The subsidiary also stated that blood loss was difficult to quantify. The oxygenator content was approximately 300 mL. The oxygenator change caused significant hemodilution, requiring massive transfusion (more so than substantial blood loss).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50180446 ↗MalfunctionDec 19, 2025Defective Component; Defective Component
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT DURING CARDIOPULMONARY BYPASS, A FAULTY MANIFOLD ON CARDIOPULMONARY BYPASS CIRCUIT. NO KNOWN CONSEQUENCE OR HEALTH IMPACT TO PATIENT. PRODUCT WAS CHANGED OUT. PROCEDURE WAS COMPLETED SUCCESSFULLY WITH LESS THAN 20 CC OF BLOOD LOSS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23850009 ↗MalfunctionNov 21, 2025Defective Device; Defective Device
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT DURING CARDIOPULMONARY BYPASS, THE OXYGENATOR WAS PRODUCING FOAM. *NO CONSEQUENCE OR HEALTH IMPACT TO PATIENT. *PRODUCT WAS NOT CHANGED OUT. *PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23619819 ↗MalfunctionMar 28, 2025Leak/Splash; Leak/Splash
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT CARDIOPULMONARY BYPASS, THERE WAS A PLASMA LEAKAGE. NO HEALTH CONSEQUENCES OR IMPACT, PRODUCT WAS NOT CHANGED OUT, PROCEDURE COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21720482 ↗MalfunctionOct 11, 2024Increase in Pressure; Increase in Pressure
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT DURING CARDIOPULMONARY BYPASS THERE WAS A HIGH PRESSURE EXCURSION. AS PER THE SUBSIDIARY UPON OPENING THE PERICARDIUM, THE PATIENT WENT INTO IRRETRACTABLE VENTRICULAR TACHYCARDIA (VTACH), WITH NO PULSE. AFTER CANNULA WERE PLACED, BYPASS WAS INITIATED. PERFUSIONIST UNABLE TO REACH FULL FLOWS WITH MAXIMUM REVOLUTIONS PER MINUTE (RPM) (LESS THAN 3.0 LITERS PER MINUTE (LPM), AT 3500 RPM, CENTRIFUGAL PUMP HEAD). NO KINKS NOTED IN ANY BYPASS CIRCUIT LINES. ARTERIAL LINE OCCULDER FULLY WITHDRAWN. TRANSESOPHAGEAL ECHOCARDIOGRAM (TEE) CONFIRMED NO AORTIC DISSECTION. CANNULA PLACEMENT ADJUSTED FOR FLOW DIRECTION. PROBLEM STILL REMAINED. FEMORAL ARTERIAL LINE PLACED TO VERIFY MEAN ARTERIAL PRESSURE (MAP) OF 35. AS TIME WENT ON ABOUT 20 MINUTES, FLOWS IMPROVED UNTIL PERFUSIONIST ABLE TO FLOW 5.0 LPM AT ~2800 RPM. NO CHANGES MADE TO BYPASS CIRCUIT. NO KNOWN CONSEQUENCE OR HEALTH IMPACT TO PATIENT , PRODUCT WAS NOT CHANGED OUT , PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20431053 ↗MalfunctionMar 6, 2024Pressure Problem; Pressure Problem
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT DURING CARDIOPULMONARY BYPASS THERE WAS A SEVERE PRESSURE EXCURSION ON THE OXYGENATOR. THERE WAS A 15 MINUTE - MINUTE DELAY TO OPEN, PRIME AND ACTIVATE ANOTHER OXYGENATOR. NO CONSEQUENCE OR IMPACT TO PATIENT *PRODUCT WAS CHANGED OUT *PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18850146 ↗MalfunctionJan 31, 2024Connection Problem; Connection Problem
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT PRIOR TO CARDIOPULMONARY BYPASS, DURING SET UP, THE VENOUS PROBE COULD NOT GET INTO THE CONNECTOR. THEY COMPLETED THE CASE WITHOUT A VENOUS BLOOD TEMPERATURE; AS THEY DID NOT CHANGED IT OUT. *NO KNOWN CONSEQUENCE OR IMPACT TO PATIENT *PRODUCT WAS NOT CHANGED OUT *PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18614399 ↗MalfunctionJan 26, 2024Particulates; Particulates
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT PRIOR TO CARDIOPULMONARY BYPASS, DURING PRIME, BLACK SPOTS DEBRIS WERE FOUND ALL OVER THE BOTTOM PART OF CARDIOTOMY RESERVOIR. *NO PATIENT INVOLVEMENT *PRODUCT WAS CHANGED OUT *PROCEDURE COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18588045 ↗MalfunctionJan 5, 2024Scratched Material; Scratched Material
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT PRIOR CARDIOPULMONARY BYPASS, DURING SETUP, A LINE/SCRATCH ON THE OXYGENATOR WAS NOTED. *NO KNOWN CONSEQUENCE AND IMPACT TO PATIENT. *THE PRODUCT WAS NOT CHANGED OUT. *PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18458118 ↗MalfunctionJan 2, 2024Dent in Material; Dent in Material
DENTED VENOUS INLET PORT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18428910 ↗MalfunctionNov 17, 2023Blocked Connection; Blocked Connection
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT PRIOR TO CARDIOPULMONARY BYPASS, DURING PRIME, THE VENOUS SAMPLING MANIFOLD RETURN LINE WAS OCCLUDED WITH A DEBRIS AT THE CONNECTION HOUSING TO THE RESERVOIR. AS PER THE SUBSIDIARY, TO MITIGATE THE ISSUE, THE USER FACILITY HAS REROUTED THE SAMPLING LINE OUTLET TO ONE OF THE LUER CONNECTORS GOING TO RESERVOIR. NO KNOWN CONSEQUENCE OR HEALTH IMPACT TO PATIENT. PRODUCT WAS NOT CHANGED OUT. PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18161640 ↗MalfunctionOct 12, 2023Pressure Problem; Pressure Problem
PRE OXYGENATOR MEMBRANE PRESSURE SLOWLY RISING AND THEN SPIKED TO ABOVE ALLOWABLE LEVELS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17926776 ↗MalfunctionSep 6, 2023Defective Component; Defective Component
RUBBER GASKET ISSUE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17694598 ↗MalfunctionSep 1, 2023Increase in Pressure; Increase in Pressure
HIGH PRE-MEMBRANE PRESSURE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17673769 ↗MalfunctionSep 1, 2023Crack; Crack
CRACKED RESERVOIR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17673761 ↗MalfunctionSep 1, 2023Crack; Crack
CRACKED RESERVOIR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17673031 ↗MalfunctionJul 18, 2023Contamination; Contamination
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT PRIOR TO CARDIOPULMONARY BYPASS, DURING PRIME, THE CUSTOMER NOTICED A SMALL FOREIGN MATTER (BLACK SPOT) IN THE OXYGENATOR RESERVOIR. NO PATIENT INVOLVEMENT. PRODUCT WAS CHANGED OUT. PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17341108 ↗MalfunctionJun 26, 2023Coagulation in Device or Device Ingredient; Coagulation in Device or Device Ingredient
OXYGENATOR RESERVOIR HAVE CLOTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17199333 ↗MalfunctionMay 26, 2023Leak/Splash; Leak/Splash
NEW INFORMATION RECEIVED INDICATED THAT THE EVENT OCCURRED DURING PRE-CARDIOPULMONARY BYPASS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17011057 ↗MalfunctionMay 24, 2023Low Readings; Low Readings
THE PO2 IN CDI SHOWED GRADUAL DECREASED (FROM 32- 11 KPA).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16995655 ↗MalfunctionMar 21, 2023Air/Gas in Device; Air/Gas in Device
THE ARTERIAL LINE HAS SMALL BUBBLES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16582596 ↗MalfunctionFeb 23, 2023Break; Break
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT DURING OUT OF BOX, THE MANIFOLD CAME OUT DAMAGE. *NO PATIENT INVOLVEMENT
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16427652 ↗MalfunctionFeb 8, 2023Device Contamination with Chemical or Other Material; Device Contamination with Chemical or Other Material
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT PRIOR TO CARDIOPULMONARY BYPASS, DURING SETUP, THEY HAVE NOTICED A BLACK MARK PARTICLE IN THE PLASTIC OF THE RESERVOIR. NO PATIENT INVOLVEMENT. THE PRODUCT WAS CHANGED OUT. THE SURGERY WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16323291 ↗InjuryFeb 1, 2023Use of Device Problem; Use of Device Problem
ADDITIONAL INFORMATION FROM THE CLINICAL SPECIALIST STATES THAT, A PARTIAL PUMP RECORD AND ONE BLOOD GAS RESULT WAS PROVIDED BY THE CUSTOMER. FROM THIS RECORD, IT CAN BE SEEN THAT AFTER INITIATING BYPASS AT 17:38, AND WITH A SUBOPTIMUM PUMP BLOOD FLOW OF ONLY 3.5 L/MIN (AT TARGET CARDIAC INDEX OF 2.5M2 THE BLOOD FLOW SHOULD HAVE BEEN 4.75L/MIN), A BLOOD GAS RESULT WAS TAKEN AT 17:41. THIS REVEALED THE FOLLOWING: PH 7.27, PCO2 50MMHG, PO2 112MMHG. WITH GAS SWEEP OF 6 LITERS AND FIO2 SETTING OF 100%. IT IS INTERESTING TO NOTE FROM THE ONE BLOOD GAS RESULT, THAT THE ARTERIAL BLOOD SATURATION WAS 98 %, WHICH IS WITHIN AN ACCEPTABLE RANGE.
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 16276917 ↗MalfunctionJan 23, 2023Increase in Pressure; Increase in Pressure
THE USER FACILITY REPORTED TO TERUMO CARDIOVASCULAR THAT DURING CARDIOPULMONARY BYPASS, THE PRE-OXYGENATOR PRESSURE CONTINUED TO RISE TO THE POINT OF BEING AT A DANGEROUS LEVEL. AS PER THE SUBSIDIARY, THE USER FACILITY INFORMED THEM THAT THEY INITIALLY WENT ON CARDIOPULMONARY BYPASS WITH AS EXPECTED PRESSURES AND GAS EXCHANGE OF THE OXYGENATOR. THROUGHOUT THE CASE THE PRE OXYGENATOR (PRE MEMBRANE) PRESSURE CONTINUED TO RISE TO THE POINT OF BEING AT A DANGEROUS LEVEL. IT GOT TO THE POINT THAT THEY HAD TO TURN THE LINK ALARM OFF, AS TO NOT CAUSE THE ARTERIAL PUMP TO TURN OFF AND THEREFORE NO LONGER BE SUPPORTING THE PATIENT. THE POST OXYGENATOR PRESSURE STAYED CONSISTENT AND DID NOT INCREASE IN UNISON WITH THE PRE MEMBRANE PRESSURE. NO KNOWN CONSEQUENCE OR IMPACT TO PATIENT. PRODUCT WAS NOT CHANGED OUT. PROCEDURE WAS COMPLETED SUCCESSFULLY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16223573 ↗
Other Reservoir, Blood, Cardiopulmonary Bypass devices
- Capiox® FX Advance Hollow Fiber Oxygenator w Integrated AF w Hardshell Res. 3CX*FX25RWCTerumo Cardiovascular Systems Corporation · Reservoir, Blood, Cardiopulmonary Bypass1 recall11 deaths286 reports
- Affinity Fusion® BB841Medtronic, Inc. · RESERVOIR, BLOOD, CARDIOPULMONARY BYPASS2 recalls36 reports
- NX19 Oxygenator w/4-liter reservoir; right-side outlet port 3CX*NX19RETerumo Cardiovascular Systems Corporation · Reservoir, Blood, Cardiopulmonary Bypass2 recalls27 reports
- Capiox® FX Advance Hollow Fiber Oxygenator w Integrated AF w Hardshell Res. 3CX*FX15RW30CTerumo Cardiovascular Systems Corporation · Reservoir, Blood, Cardiopulmonary Bypass3 deaths57 reports
- Better-Bladder BB14Circulatory Technology Inc · RESERVOIR, BLOOD, CARDIOPULMONARY BYPASS1 recall5 reports
- Affinity Pixie™ BBP241Medtronic, Inc. · RESERVOIR, BLOOD, CARDIOPULMONARY BYPASS1 recall2 reports
- Affinity Fusion™ BB841Medtronic, Inc. · Reservoir, blood, cardiopulmonary bypass44 reports
- NX19 Oxygenator w/4-liter reservoir; left-side outlet port 3CX*NX19RWTerumo Cardiovascular Systems Corporation · Reservoir, Blood, Cardiopulmonary Bypass3 deaths31 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page