Cardiovascular Procedure Kit 73957-02Recalls & reported problems

Terumo Cardiovascular Systems Corporation

All models of Cardiovascular Procedure Kit (227)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 00699753507012), received between Nov 20, 2023 and Nov 20, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Air/Gas in Device” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Air/Gas in Device1
  • Leak/Splash1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 20, 2023Leak/Splash; Air/Gas in Device; Leak/Splash; Air/Gas in Device

    PER CLINICAL REVIEW: THIS COMPLAINT INVOLVED A CP50 CARDIOPLEGIA DELIVERY UNIT THAT LEAKED DURING CARDIOPULMONARY BYPASS. THE LEAK OCCURRED AROUND THE TEMPERATURE THERMISTOR LOCATED ON THE OUTFLOW PORT OF THE CP50 UNIT. THE CP50 UNIT WAS CHANGED OUT. THERE WAS A LOSS OF APPROXIMATELY 200CC OF BLOOD. THE CP50 UNIT WAS RETURNED TO THE MANUFACTURER FOR INVESTIGATION. UPON INSPECTION, THE LEAK WAS CONFIRMED ON THE COMPLAINT UNIT. THE MANUFACTURING RECORDS AT THAT TIME REVEALED NO ANOMALIES IN PRODUCTION. THE MOST LIKELY CAUSE WAS WORKMANSHIP ERROR, POSSIBLY AS A RESULT OF A LOOSE THERMISTOR BEING RE-TIGHTENED BY PRODUCTION ASSOCIATES AND THEN BEING SUBJECTED TO STRESS DURING HEAT STERILIZATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18172664 ↗