Cardiovascular Procedure Kit 75564-01Recalls & reported problems

Terumo Cardiovascular Systems Corporation

All models of Cardiovascular Procedure Kit (227)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 00699753516069), received between Oct 28, 2025 and Oct 31, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Crack” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 3 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Crack3
  • Leak/Splash3
  • Pressure Problem3

Patient problems

  • No Clinical Signs, Symptoms or Conditions3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 31, 2025Crack; Leak/Splash; Pressure Problem; Crack; Leak/Splash; Pressure Problem

    IT WAS REPORTED THAT DURING USE OF THE DEVICE FOR CARDIOPULMONARY BYPASS (CPB), THE MALE CONNECTOR ON LINE 11 LEAKED DUE TO A CRACK IN THE CONNECTOR AND COULD NOT PROVIDE ENOUGH PRESSURE TO UTILIZE THE CARDIOPLEGIA LINE. AS MITIGATION, THE TEAM REPLACED THE LINE WITH AN EIGHT-FOOT PRESSURE LINE. THE SURGICAL PROCEDURE WAS COMPLETED SUCCESSFULLY. THERE WAS NO DELAY, NO BLOOD LOSS, NOR ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23437402 ↗
  • MalfunctionOct 31, 2025Crack; Leak/Splash; Pressure Problem; Crack; Leak/Splash; Pressure Problem

    PER CLINICAL REVIEW: THIS COMPLAINT INVOLVED A TUBING PACK THAT HAD A MALE CONNECTOR IN ONE OF THE ANCILLARY TUBING LINES LEAK BLOOD DURING CARDIOPULMONARY BYPASS. THE LINE AND CONNECTOR WERE CHANGED OUT WITH ANOTHER LINE/CONNECTOR AND THERE WAS NO HARM TO THE PATIENT. THE LINE AND CONNECTOR WERE NOT RETURNED TO THE MANUFACTURER FOR INVESTIGATION, AND NO PICTURES WERE TAKEN BY THE CUSTOMER AND SHARED. THIS COMPLAINT IS MOST LIKELY A WORKMANSHIP ISSUE WITH NOT ENOUGH SOLVENT BOND APPLICATION TO THE LINE AND CONNECTOR, BUT WITHOUT THE RETURN OF THE COMPLAINT DISPOSABLE, IT IS DIFFICULT TO GIVE A DEFINITIVE ROOT CAUSE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23437356 ↗
  • MalfunctionOct 28, 2025Crack; Leak/Splash; Pressure Problem; Crack; Leak/Splash; Pressure Problem

    IT WAS REPORTED THAT DURING USE OF THE DEVICE FOR CARDIOPULMONARY BYPASS (CPB), THE MALE CONNECTOR ON LINE 11 LEAKED DUE TO A CRACK IN THE CONNECTOR AND COULD NOT PROVIDE ENOUGH PRESSURE TO UTILIZE THE CARDIOPLEGIA LINE. AS MITIGATION, THE TEAM REPLACED THE LINE WITH AN EIGHT-FOOT PRESSURE LINE. THE SURGICAL PROCEDURE WAS COMPLETED SUCCESSFULLY. THERE WAS NO DELAY, NO BLOOD LOSS, NOR ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23410390 ↗