Skip to content

Atellica® VTR Syringes 11561341Recalls & reported problems

Westmed, Inc. · 1mL A-Line Aspirating Luer Slip Syringe, ~25IU Balanced Heparin, Vented Tip Cap (Private Label) · Class 1

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 00709078013300), received between Nov 21, 2024 and Nov 22, 2024 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Fitting Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 2 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fitting Problem1
  • Insufficient Device Problem Information1

Patient problems

  • Insufficient Information1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 22, 2024Insufficient Device Problem Information; Insufficient Device Problem Information

    SUNMED HOLDINGS LLC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT SAMPLES. THIS IS THE FIRST OF TWO REPORTS. REFER TO 2028807-2024-00074 FOR THE SECOND REPORT. IT WAS REPORTED, THE SAMPLE CLOTTED IN THE ATELLICA VTR SYRINGE; THERE WAS NO REPORTED INJURY OR DELAY OF RESULTS OR TREATMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20762261 ↗
  • MalfunctionNov 21, 2024Fitting Problem; Fitting Problem

    SUNMED HOLDINGS LLC. RECEIVED A SINGLE REPORT THAT REFERENCED TWO DIFFERENT INCIDENCES, WHICH WERE ASSOCIATED WITH SEPARATE UNITS, INVOLVING TWO DIFFERENT PATIENTS. THIS IS THE FIRST OF TWO REPORTS. REFER TO 2028807-2024-00072 FOR THE SECOND REPORT . IT WAS REPORTED, POORLY FITTING SYRINGE CAP LEAD TO BLOOD LEAKING AND CONTAMINATION DUE TO FILTER CAP POPPING OFF DURING AIR EXPULSION POST BLOOD COLLECTION. NO ADDITIONAL INFORMATION CONCERNING THE CONTAMINATION WAS PROVIDED; THERE WAS NO REPORTED INJURY.

    Patient problems: Insufficient Information

    MAUDE report 20753819 ↗

Other Arterial Blood Sampling Kit devices

All Arterial Blood Sampling Kit devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page